You can hardly find water which has no problem with one of 5 typical You can hardly find water which has no problem with one of 5 typical contaminants: ü Hardness ü Iron ü Manganese ü Natural organic matter (NOM) ü Smell of ammonia and/or H 2 S These problems often come together.

Traditionally – 4 stages 1. Iron and manganese removal on catalytic media (Birm, MTM, Traditionally – 4 stages 1. Iron and manganese removal on catalytic media (Birm, MTM, Greensand, etc). 2. Softening on strong acid cation resins (ammonia removal is also possible). 3. Organics removal by activated carbon. 4. (Potentially) Ammonia removal on zeolite.

Problems with traditional technology: • detailed water analysis • deep knowledge and experience of Problems with traditional technology: • detailed water analysis • deep knowledge and experience of water experts • is quite expensive and imperfect • creates headaches and problems during maintenance

Some facts: In 1999 started production of ECOMIX. Since 2001 – in Russia, Belarus Some facts: In 1999 started production of ECOMIX. Since 2001 – in Russia, Belarus Since 2004 – in Germany, Italy, Poland, Scandinavian and Baltic countries In 2007 -2010 600 000 liters of media sold Lifetime of the media - 3 -10 years (average 5 years) Problems - less than 0, 1%

ECOMIX® is a mixture of ion exchange and adsorption materials of different nature 5 ECOMIX® is a mixture of ion exchange and adsorption materials of different nature 5 components which are created in our Kiev facility

After 1 st backwash creates a multilayer arrangement that provides a maximum efficiency of After 1 st backwash creates a multilayer arrangement that provides a maximum efficiency of purification.

Inert material for iron removal and correct flow arrangement during backwash Modified adsorbent for Inert material for iron removal and correct flow arrangement during backwash Modified adsorbent for Fe and Mn removal Modified adsorbent for NOM removal Low-crosslinked cation resin Quartz sand support bed

Mechanism: • ion-exchange • adsorption • catalytic • contact coagulation. Regeneration - Na. Cl Mechanism: • ion-exchange • adsorption • catalytic • contact coagulation. Regeneration - Na. Cl

Mechanism: • ion-exchange • adsorption • catalytic • contact coagulation. Regeneration - Na. Cl Mechanism: • ion-exchange • adsorption • catalytic • contact coagulation. Regeneration - Na. Cl

Two types of the media are available: • ECOMIX ® А « 4 -in-1» Two types of the media are available: • ECOMIX ® А « 4 -in-1» - more popular, effective in hardness, iron, manganese and ammonia removal. It removes organic at certain level. • ECOMIX ® C « 5 -in-1» - is recommended when besides 4 main contaminants significant reduction of organic content is necessary.

Concentration limits TYPE A Hardness, ppm Ca. CO 3 Fe, ppm Mn, ppm COD, Concentration limits TYPE A Hardness, ppm Ca. CO 3 Fe, ppm Mn, ppm COD, ppm KMn. O 4 Raw water < 750 < 15 < 3 < 16 Filtered water Max 20 TYPE C Hardness, ppm Ca. CO 3 Raw water < 750 Filtered water Max 20 < 0, 2 < 0, 05 < 8 Fe, ppm Mn, ppm COD, ppm KMn. O 4 < 10 < 3 < 80 < 0, 2 < 0, 05 < 8 NH 4 ppm TDS, ppm <4 <0, 5 < 4000 No changes

Quality ECOMIX ® is made of the DOWEX resins, which undergo additional chemical treatment Quality ECOMIX ® is made of the DOWEX resins, which undergo additional chemical treatment at our site. In Dec. 2010 - EU sanitary certification Packing - 25 (12) liter double PE bags

SPECIFICATIONS Shipping weight, kg/liter Maximum operating temperature, 0 C p. H Minimum bed depth, SPECIFICATIONS Shipping weight, kg/liter Maximum operating temperature, 0 C p. H Minimum bed depth, mm Optimum bed depth, mm 0, 75 40 5 - 10 500 800

SPECIFICATIONS Flow rate, m/h: service 20 - 25 backwash ( 15 -20 min) 13 SPECIFICATIONS Flow rate, m/h: service 20 - 25 backwash ( 15 -20 min) 13 -15 regeneration (45 -65 min) rinse (15 -20 min) 3 - 5 20 - 25 Free bed volume >40% Water consumption for regeneration, l 4 - 6 Regeneration solution 8 -10 % Na. Cl

CAPACITY AND REGENERATION Only hardness should be considered for calculations TYPE A 0, 75 CAPACITY AND REGENERATION Only hardness should be considered for calculations TYPE A 0, 75 eq/l(37, 5 g. Ca. CO 3/l) TYPE C 0, 65 eq/l (32, 5 g. Ca. CO 3/l) Regeneration: 100 g Na. Cl/l media

The most typical applications: • • Residential water treatment for private houses Commercial treatment The most typical applications: • • Residential water treatment for private houses Commercial treatment for food industry Pretreatment before RO Replacement of standard softening for boilers and steam generators

Main Advantages of the systems with ECOMIX: • Universal solution. Five major problems of Main Advantages of the systems with ECOMIX: • Universal solution. Five major problems of well water are easily solved by just one filter • High efficiency. Filter is more effective than traditional iron removal systems. Fe < 15 ppm and Mn<3 ppm, rejection– up to 99%. • Consistent reliability. Efficiency does not depend on p. H, organics, chlorine or hydrogen sulfide content. The most reliable technology for iron removal – treats ANY well water.

Main Advantages of the systems with ECOMIX: • Proven technology. 15 000 systems operating Main Advantages of the systems with ECOMIX: • Proven technology. 15 000 systems operating for 12 years all around Europe. • Easy operation. Simple calculation of capacity – just hardness is taken into consideration. Extremely low salt consumption. • Compact size – a new concept allows to reduce the overall size of the system substantially so it requires a smaller footprint. Cabinet size unit can serve for the whole house.

1. ECOMIX IS NOT JUST A MIXTURE OF ANION AND CATION RESINS 2. AFTER 1. ECOMIX IS NOT JUST A MIXTURE OF ANION AND CATION RESINS 2. AFTER 12 YEARS OF APPLICATION WE KNOW HOW TO MAKE IT WORKING 3. ECOMIX IS BETTER THEN THE ONLY COMPETING ZEOLITE-BASED PRODUCT