XL 2 Audio and Acoustic Analyzer Introducing the new flagship of the handheld EXEL XL 2 Audio and Acoustic Analyzer Introducing the new flagship of the handheld EXEL line. 11, V 1. 0 Oct. 09

XL 2 Audio and Acoustic Analyzer • Sound Level Meter Real Time Analyzer XL 2 Audio and Acoustic Analyzer • Sound Level Meter Real Time Analyzer

XL 2 Audio and Acoustic Analyzer • • Sound Level Meter Real Time Analyzer XL 2 Audio and Acoustic Analyzer • • Sound Level Meter Real Time Analyzer Acoustic Analyzer

XL 2 Audio and Acoustic Analyzer • • • Sound Level Meter Real Time XL 2 Audio and Acoustic Analyzer • • • Sound Level Meter Real Time Analyzer Acoustic Analyzer STI-PA Analyzer

XL 2 Audio and Acoustic Analyzer • • Sound Level Meter Real Time Analyzer XL 2 Audio and Acoustic Analyzer • • Sound Level Meter Real Time Analyzer Acoustic Analyzer STI-PA Analyzer Audio Analyzer

XL 2 Applications • • • Live Sound Solutions Sound Installations and Recording Studios XL 2 Applications • • • Live Sound Solutions Sound Installations and Recording Studios Broadcast Environmental Noise Measurements Service and Repair Centers

XL 2 Configurations • + Set XL 2 + M 2210 XL 2 with XL 2 Configurations • + Set XL 2 + M 2210 XL 2 with M 2210 - Extended Performance Measurement Microphone with class 1 frequency response M 2210 • Set XL 2 + M 4260 XL 2 with M 4260 Measurement Microphone, Class 2 + M 4260

XL 2 Interfaces XL 2 Interfaces

Big LCD 160 x 160 with Backlight Function Buttons Big LCD 160 x 160 with Backlight Function Buttons

Rotary Wheel Limit LED with red, yellow, green Indication Rotary Wheel Limit LED with red, yellow, green Indication

Shock Protection Jacket Shock Protection Jacket

Headphone Output Headphone Output

Wire Stand Wire Stand

Battery Compartment with Li-Po Battery included Rear Speaker Battery Compartment with Li-Po Battery included Rear Speaker

Balanced & Unbalanced Input Tripod Mount Balanced & Unbalanced Input Tripod Mount

Voice Note Microphone Voice Note Microphone

Mains Power Adapter Input USB Interface Digital I/O (prepared for later firmware extension) Mains Power Adapter Input USB Interface Digital I/O (prepared for later firmware extension)

Mini-SD Card 2 GByte Removable Mini-SD Card 2 GByte Removable

TOSLink Output (prepared for later firmware extension) TOSLink Output (prepared for later firmware extension)

XL 2 Key Features XL 2 Key Features

XL 2 Features • • • Flexible User Interface Visual Limit LED of high XL 2 Features • • • Flexible User Interface Visual Limit LED of high sound levels Mini-SD Card, 2 GB removable Real Time Clock Built-in Speaker Rechargeable Li-Po Battery included Automated Sensor Detection reads electronic data sheet of M 4260 and M 2210 Wave File Recording Voice Notes

XL 2 Sound Level Meter / RTA • Applications – Live Sound Events – XL 2 Sound Level Meter / RTA • Applications – Live Sound Events – Environmental Noise Monitoring

XL 2 Sound Level Meter / RTA • • Measures actual level, Leq, Lmin, XL 2 Sound Level Meter / RTA • • Measures actual level, Leq, Lmin, Lmax, LCpeak, … Frequency weighting A, C, Z Time Weighting F, S, Peak, I* Linear operating range > 100 d. B XL 2 accuracy acc. IEC 61672, class 1 Logs automatically to Mini-SD card Real time clock *optional

XL 2 Sound Level Meter / RTA Extended Acoustic Pack • Percentiles %: 1, XL 2 Sound Level Meter / RTA Extended Acoustic Pack • Percentiles %: 1, 5, 10, 50, 95, 99% • Time Weighting: Impulse • Sound Pressure Level LIeq • Sound Exposure Level LAE • Takt. Max as specified in DIN 45645 -1 • High-resolution FFT with 0. 4 Hz steps

XL 2 Sound Level Meter / RTA • All measurement results are simultaneously available. XL 2 Sound Level Meter / RTA • All measurement results are simultaneously available. • Select the available levels to be shown on the XL 2 display

XL 2 Sound Level Meter / RTA • 3 or 5 levels may be XL 2 Sound Level Meter / RTA • 3 or 5 levels may be displayed simultaneously in different selectable sizes

XL 2 Sound Level Meter / RTA • • • Displays two spectra simultaneously XL 2 Sound Level Meter / RTA • • • Displays two spectra simultaneously Resolution selectable Broadband values displayed in parallel Measurement range selectable Measurement time and control

XL 2 Sound Level Meter / RTA • • Pre-defined limits for all levels XL 2 Sound Level Meter / RTA • • Pre-defined limits for all levels Firmware V 1. 00 operates with fixed limits – Level ok Limit LED is GREEN – Level near limit LED is YELLOW – Limit exceeded LED is RED

XL 2 Live Sound Challenges Stage • Sound pollution protection limits maximum level in XL 2 Live Sound Challenges Stage • Sound pollution protection limits maximum level in audience area. • Loudest audience position is commonly not accessible for measurements. • XL 2 offers a wizard to measure correction values k 1 and k 2 between loudest position and measurement point Loudest accesible position Audience position k 1 = Difference in LAeq k 2 = Difference in LCPeak Measurement Position FOH Public listening area

XL 2 Correction Value Wizard • • Run Pink Noise in the auditorium Measure XL 2 Correction Value Wizard • • Run Pink Noise in the auditorium Measure level at the loudest position Measure level at the measurement point, e. g. at the mixing desk FOH XL 2 stores results with time stamp and displays the calculated correction values k 1 and k 2

XL 2 Audio Analyzer • • • Balanced XLR, unbalanced RCA input -112 d. XL 2 Audio Analyzer • • • Balanced XLR, unbalanced RCA input -112 d. Bu to 30 d. Bu (2. 0 u. V to 25 V) Residual THD+N <-100 d. B (0. 001%) Frequency range: 9 Hz to 20 k. Hz Frequency accuracy: 0. 003% Loudspeaker and headset output for signal monitoring

XL 2 FFT Analyzer • • Measures LZF and Leq simultaneously Real time FFT XL 2 FFT Analyzer • • Measures LZF and Leq simultaneously Real time FFT in 3 linear ranges displayed by 142 frequencies – 7 Hz - 215 Hz – 58 Hz - 1. 72 k. Hz – 484 Hz - 20. 5 k. Hz • High-resolution FFT including zoom mode up to 0. 4 Hz steps with Extended Acoustic Pack in the range from 5 Hz – 20 k. Hz

XL 2 RT 60 Analyzer • • • Measures 8 octave bands from 63 XL 2 RT 60 Analyzer • • • Measures 8 octave bands from 63 Hz – 8 k. Hz according to ISO 3382 by Schroeder-method Auto triggering Auto averaging Measurement error indication Stimulus: – Gated pink noise – Impulse sound source

XL 2 Polarity Testing • • • Checks polarity of speaker cabinets, individual drivers XL 2 Polarity Testing • • • Checks polarity of speaker cabinets, individual drivers and line signals Positive/Negative detection Using internal microphone or input signal of XLR/RCA connector

XL 2 Polarity Testing • In-depth verification of the polarity frequency relation for speaker XL 2 Polarity Testing • In-depth verification of the polarity frequency relation for speaker cabinets or other multi-way-systems • Sample Screenshot left: The major part of the signal energy is measured in the mid-range frequency bands, thus the overall displayed polarity is NEGATIVE.

XL 2 Propagation Delay • • For accurate setup of delay line arrangements Measures XL 2 Propagation Delay • • For accurate setup of delay line arrangements Measures delay between electrical reference and acoustical signal Relative measurements supported Displays distance to speaker in meter or feet

XL 2 STI-PA* Analyzer • • • Measures speech intelligibility of public announcement systems XL 2 STI-PA* Analyzer • • • Measures speech intelligibility of public announcement systems Complies with IEC 60268 -16 (2003) and NFPA 72 Displays STI and CIS results Shows table of modulation indices and Leq’s Supports ambient noise post processing *optional

XL 2 Application Profiles • • XL 2 supports application profiles Application profile may XL 2 Application Profiles • • XL 2 supports application profiles Application profile may disable and hide any selections or measurement functions Allows fixed operator interfaces for basic users Firmware V 1. 0 offers a set of fixed application profiles

XL 2 Store and Log Results • • Results stored as ASCII files Storing XL 2 Store and Log Results • • Results stored as ASCII files Storing all or subsets of measurements results Adding a voice note to measurement Records the ADPCM compressed audio signal in parallel

XL 2 Automated Sensor Detection • Automatically detects microphone type – Reads sensitivity – XL 2 Automated Sensor Detection • Automatically detects microphone type – Reads sensitivity – Reads product data – Shows last calibration • ASD Cable Extension cable tandem up to 20 m supported

XL 2 Powering Concept • Rechargeable Li-Po battery – included – typical battery lifetime XL 2 Powering Concept • Rechargeable Li-Po battery – included – typical battery lifetime > 5 hours • Dry cell batteries – type AA, 4 x 1. 5 V – typical battery lifetime > 4 hours • Mains power supply 9 VDC – charges Li-Po battery in operation

Measurement Microphones Measurement Microphones

XL 2 Measurement Microphones • • M 2210 M 4260 Omni-directional, pre-polarized condenser, free-field XL 2 Measurement Microphones • • M 2210 M 4260 Omni-directional, pre-polarized condenser, free-field microphone Build-in Pre-amplifier Electronic Data Sheet installed Phantom Power 48 VDC High dynamic range Wide frequency range Low residual noise

XL 2 Comparison of Microphones M 4260 M 2210 – Extended Performance 1/4” permanently XL 2 Comparison of Microphones M 4260 M 2210 – Extended Performance 1/4” permanently installed capsule 1/2” detachable capsule with 60 UNS 2 thread Capsule / Transducer Flatness Class 2 (IEC 61672 -1) < ± 1. 4 d. B @ 100 Hz - 1250 Hz < ± 3. 5 d. B @ 20 Hz - 20 k. Hz Frequency Range 20 Hz - 20 k. Hz 1 Hz - 20 k. Hz Residual Noise Floor typical 24 d. B(A) 18 d. B(A) Upper Limit of Dynamic Range typ. 136 d. BSPL 145 d. BSPL Sensitivity typical -30 d. BV/Pa ± 4 d. B (30 m. V/Pa @ 1 k. Hz) -34 d. BV/Pa ± 3 d. B (20 m. V/Pa @ 1 k. Hz) Class 1 (IEC 61672 -1) < ± 1. 1 d. B @ 100 Hz - 4 k. Hz < ± 2. 5 d. B @ 10 Hz - 20 k. Hz

XL 2 Accessories XL 2 Accessories

XL 2 Accessories • Ever-Ready pouch – Detachable front flap – Connectors accessible – XL 2 Accessories • Ever-Ready pouch – Detachable front flap – Connectors accessible – Zipper • EXEL System Case – Compartments for XL 2, MR-PRO, M 4260 or M 2210 – Accessories, battery and adapter

XL 2 Accessories • Battery Charger – Includes spare battery – Connects to 100 XL 2 Accessories • Battery Charger – Includes spare battery – Connects to 100 -230 V AC – Intelligent charger controller • Spare Battery – rechargeable spare battery – Li-Po battery

XL 2 Accessories • ASD Cable – For extended connections of the measurement microphones XL 2 Accessories • ASD Cable – For extended connections of the measurement microphones M 4260 or M 2210 – Maintaining the automated sensor detection – Length = 5 meter (16 feet) • External AC power supply – Suitable also for use with MR-PRO – Operates XL 2 and chargers Li-Po battery in parallel

XL 2 Firmware Options • Extended Acoustic Pack – Percentiles: 1%, 5%, 10%, 50%, XL 2 Firmware Options • Extended Acoustic Pack – Percentiles: 1%, 5%, 10%, 50%, 90%, 95%, 99% – Time Weighting: Impulse – Sound Pressure Level LIeq – Sound Exposure Level LAE – High-resolution FFT including zoom mode up to 0. 4 Hz steps in the range of 5 Hz - 20 k. Hz – Takt. Max and values as specified in DIN 45645 -1

XL 2 Firmware Options • STI-PA Option – Measures speech intelligibility of public announcement XL 2 Firmware Options • STI-PA Option – Measures speech intelligibility of public announcement systems – Complies with IEC 60268 -16 (2003) and NFPA 72 – Displays STI and CIS results