Скачать презентацию The Heat Elite CEO- Hayley Dircherl CFO- Jeff Скачать презентацию The Heat Elite CEO- Hayley Dircherl CFO- Jeff

60ac3778ca8b869641e16e81a8db4f8f.ppt

  • Количество слайдов: 15

The Heat Elite CEO- Hayley Dircherl CFO- Jeff Chiang CTO- Sara Mc. Ardle CMO- The Heat Elite CEO- Hayley Dircherl CFO- Jeff Chiang CTO- Sara Mc. Ardle CMO- Leah Peterson CRO- Philip Kemp

Design Problem Heat stroke THIRD leading cause of death among athletes in the United Design Problem Heat stroke THIRD leading cause of death among athletes in the United States. High temperature/high humidity increases heart rate, prevents body from effectively dissipating heat. Overheating, Exceeding limits exhaustion and cramps, common problems in athletes Hyperthermia Thermoregulatory mechanisms fail, organ damage or death. Symptoms: Seizures, disorientation, confusion, unconsciousness, coma

Design Brief Device to measure BOTH temperature and heart rate Conveniently and comfortably worn Design Brief Device to measure BOTH temperature and heart rate Conveniently and comfortably worn on the body during athletic activity. SIMPLE, user-friendly display, ALERTS user to stop activity when necessary

Thermoregulatory Breakdown • Dehydration • Loss of core-to-shell temperature gradient • Central Fatigue and Thermoregulatory Breakdown • Dehydration • Loss of core-to-shell temperature gradient • Central Fatigue and Vasodilation http: //www. icsspe. org/members/bulletin/bilder 48/4 -1 -figure 5. gif http: //www. extension. iastate. edu/nutrition/sport/images/dehydration. jpg

The Heat Elite Solution. Therma. Tracker Infrared Emission Detector Thermometer • Feasibility • Accuracy The Heat Elite Solution. Therma. Tracker Infrared Emission Detector Thermometer • Feasibility • Accuracy • Comfort Photoplethysmography Transmission Pulse Oximeter on Earlobe Reflectance Pulse Oximeter on Forehead/Temple http: //www. medis-de. com/en/ppg. html

Specifications and Constraints • Measures BOTH heart rate and body temperature, allows for prediction Specifications and Constraints • Measures BOTH heart rate and body temperature, allows for prediction of heat exhaustion, not just a training tool. • Wireless technology ensures portability of device. • The device must be comfortable to wear so as to not hinder athletic performance. • Accuracy of measurements is essential to prevent fatality and unnecessary withdrawal from athletic events. • Will be water resistant to prevent electric shock.

Specifications and Constraints • Battery life will be sufficient to power device through the Specifications and Constraints • Battery life will be sufficient to power device through the length of athletic events. • Temperature and heart rate measurements will be easily readable by the user/trainer and equipped with an alarm for when unsafe levels are reached. • Customer: Athletic departments, e. g. college level and below • User: Athletes of organized sports, e. g. football and cross country • The cost to buy the device must be minimized so that school athletic programs can afford it.

Available Products In-Ear IR Thermometer Cor. Temp Ingestible Pill Thermometer Data. Therm® Temperature Monitor/Recorder Available Products In-Ear IR Thermometer Cor. Temp Ingestible Pill Thermometer Data. Therm® Temperature Monitor/Recorder Polar® Heart Rate Monitors (EKG) Strapless Heart Rate Monitors Wrist-worn Touch Electrical Sensor (non-continuous) e. Pulse Forearm-worn Sensor Power. Glove Hand-worn Sensor Oxi. Max® Max-Fast® Forehead Pulse. Ox

Related products- Earphones Sony Fontopia Designed to fit “snugly, yet comfortably” inside ear during Related products- Earphones Sony Fontopia Designed to fit “snugly, yet comfortably” inside ear during exercise Anti-bacterial soft rubber Neodymium magnet for power in small size • Motorola Bluetooth Active Headphones – Receives information through bluetooth receiver at the back of the head – Different ear bud design – Designed for stability during activity

Collaboration between Nike and Apple Monitors workout parameters Time, distance, pace, calories burned Displays Collaboration between Nike and Apple Monitors workout parameters Time, distance, pace, calories burned Displays visually on screen or audibly through headphones Must buy i. Pod Nano, special Nike sneaker

Temperature Sensor -Detects Infrared Emission -Fits comfortably inside ear -Only need to wear one Temperature Sensor -Detects Infrared Emission -Fits comfortably inside ear -Only need to wear one Bluetooth Device Idea 1 Receiver/Data Processor Pulse-Oximeter -Displays temperature, heart rate -Sends data wirelessly to receiver -Connected to pulse ox via -Measures heart rate continuously wire -Fits snugly behind ear -Battery powered -Detects change in infrared -Elastic or velcro strap transmittance -Softly padded, wraps around thumb

Idea 2 Temperature Sensor -Infrared detection -Averaged between both ears Processing. Transmitter Heart rate Idea 2 Temperature Sensor -Infrared detection -Averaged between both ears Processing. Transmitter Heart rate monitor Bluetooth Unit -Clipped to user or held by trainer -Pulse-ox technology -Modeled after related product -Bluetooth receiver -Reflectance or Transmittance -Battery Powered

Idea 3 Wireless Transmitter In Ear Portable Monitoring Thermometer. Pulse Reflectance -Non-contact casing and Idea 3 Wireless Transmitter In Ear Portable Monitoring Thermometer. Pulse Reflectance -Non-contact casing and Battery IR lens Station on Sideline Oximetry at Temple -Ear bulb, soft rear snugly -Embedded in to fit helmet padding

Summary Heat stroke in athletes is a common medical problem that can be fatal Summary Heat stroke in athletes is a common medical problem that can be fatal Proposed Therma. Tracker can measure core temperature and heart rate Infrared Emission Photoplethysmography Displays heart rate and temperature Diagnose and warn about impending heat stroke Save Lives! The Heat Elite… It’s like “THE”