Скачать презентацию Tag Master Training 2013 GEN 4 Software Applications Скачать презентацию Tag Master Training 2013 GEN 4 Software Applications

c8aa464090a029974bc2ce4a7b6b38f9.ppt

  • Количество слайдов: 19

Tag. Master Training 2013 GEN 4 Software Applications VAC Tag. Master AB Tag. Master Tag. Master Training 2013 GEN 4 Software Applications VAC Tag. Master AB Tag. Master Training Module T 6, Page 1

Contents § § § Software Application Overview Relevant Documentation Details § § § Tag. Contents § § § Software Application Overview Relevant Documentation Details § § § Tag. Master AB Wise. Man Watch. Man Pass. Man Tag. Master Training Module T 6, Page 2

Tag. Master’s Access Applications § Wise. Man § § Watch. Man § § Reader Tag. Master’s Access Applications § Wise. Man § § Watch. Man § § Reader connected to external system via RS 232/RS 485 (Confi. Talk polling protocol) ID-tag database in external system External system makes decisions and tells the reader when to open the gate Pass. Man § § § Tag. Master AB Stand-alone system ID-tag database in reader Reader makes decisions and controls the gate Reader connected to existing access control system via Wiegand/Mag-stripe interface ID-tag database in access control system Access control system makes decisions and opens the gate Tag. Master Training Module T 6, Page 3

Wise. Man Tag. Master AB Tag. Master Training Module T 6, Page 7 Wise. Man Tag. Master AB Tag. Master Training Module T 6, Page 7

Wise. Man § § § Tag. Master AB Stand-alone (or host-controlled) system ID-tag database Wise. Man § § § Tag. Master AB Stand-alone (or host-controlled) system ID-tag database in reader Reader makes decisions and controls the gate Tag. Master Training Module T 6, Page 8

Wise. Man functional overview Tag. Master AB Tag. Master Training Module T 6, Page Wise. Man functional overview Tag. Master AB Tag. Master Training Module T 6, Page 9

Wise. Man § Functional inputs: § § § Functional outputs § § § ID-tag Wise. Man § Functional inputs: § § § Functional outputs § § § ID-tag Tamper switch Moving objects Info from host Relay Buzzer LED Info to host Log is volatile (RAM) Database in non-volatile (Flash) Stand-alone installation using Wise. Man Tag. Master AB Tag. Master Training Module T 6, Page 10

Wise. Man § Host communication: § § § RS 232 RS 485 (2 -wire) Wise. Man § Host communication: § § § RS 232 RS 485 (2 -wire) RS 485 (4 -wire) § Host communication is using protocol Confi. Talk § Configuration can be done using § § § Tag. Master AB Web interface (TCP/IP) Terminal interface (Service port) Serial communication messages (RS 232, 2 -wire RS 485, 4 -wire RS 485) Tag. Master Training Module T 6, Page 11

Watch. Man Tag. Master AB Tag. Master Training Module T 6, Page 16 Watch. Man Tag. Master AB Tag. Master Training Module T 6, Page 16

Watch. Man § § § Tag. Master AB Reader connected to external system via Watch. Man § § § Tag. Master AB Reader connected to external system via RS 232/RS 485 (Confi. Talk) ID-tag database in external system External system makes decisions and tells the reader to open the gate Tag. Master Training Module T 6, Page 17

Watch. Man functional overview Tag. Master AB Tag. Master Training Module T 6, Page Watch. Man functional overview Tag. Master AB Tag. Master Training Module T 6, Page 18

Watch. Man § Functional inputs: § § § ID-tag Inputs (3) Moving objects Info Watch. Man § Functional inputs: § § § ID-tag Inputs (3) Moving objects Info from host Functional outputs § § § Relay Outputs (2) Buzzer LED Info to host Host controller installation using Watch. Man Tag. Master AB Tag. Master Training Module T 6, Page 19

Watch. Man § Host communication: § § § RS 232 RS 485 (2 -wire) Watch. Man § Host communication: § § § RS 232 RS 485 (2 -wire) RS 485 (4 -wire) § Host communication is using protocol Confi. Talk § Configuration can be done using § § § Tag. Master AB Web interface (TCP/IP) Terminal interface (Service port) Serial communication messages (RS 232, 2 -wire RS 485, 4 -wire RS 485) Tag. Master Training Module T 6, Page 20

Pass. Man Tag. Master AB Tag. Master Training Module T 6, Page 24 Pass. Man Tag. Master AB Tag. Master Training Module T 6, Page 24

Pass. Man § § § Tag. Master AB Reader connected to existing access control Pass. Man § § § Tag. Master AB Reader connected to existing access control system via Wiegand / Mag-stripe / serial interface ID-tag database in access control system Access control system makes decisions and opens the gate Tag. Master Training Module T 6, Page 25

Pass. Man functional overview, Access Control Pass. Man functional overview, Host application Tag. Master Pass. Man functional overview, Access Control Pass. Man functional overview, Host application Tag. Master AB Tag. Master Training Module T 6, Page 26

Pass. Man § Functional inputs: § § § ID-tag Loop trigger Moving objects (Info Pass. Man § Functional inputs: § § § ID-tag Loop trigger Moving objects (Info from host) Functional outputs § § § Info to access control system Relay Buzzer LED (Info to host) A typical installation using Pass. Man is an extension of an existing access control system Tag. Master AB Tag. Master Training Module T 6, Page 27

Pass. Man § Access Control System Communication § § Host communication: § § Serial Pass. Man § Access Control System Communication § § Host communication: § § Serial (RS 232, 2 -wire RS 485) Configuration can be done using § § § Tag. Master AB Wiegand Mag-stripe Serial (RS 232, 2 -wire RS 485) Web interface (TCP/IP) Terminal interface (Service port) Pass. Man terminal interface (RS 232/RS 485) Tag. Master Training Module T 6, Page 28

End VAC Tag. Master AB Tag. Master Training Module T 6, Page 35 End VAC Tag. Master AB Tag. Master Training Module T 6, Page 35