Siemens Applied Automation Process Gas Chromatography Ne. SSI Update An Implementation of the Generation Siemens Applied Automation Process Gas Chromatography Ne. SSI Update An Implementation of the Generation 2 Bus Siemens Activities November 2006 Siemens Update ro Ne. SSI / CPAC. ppt Slide 1; CPAC; November 2006

Siemens Applied Automation Topics Process Gas Chromatography Ø Summary Siemens activities Ø Review of Siemens Applied Automation Topics Process Gas Chromatography Ø Summary Siemens activities Ø Review of key bus requirements Ø Current status of Siemens implementation Siemens Update ro Ne. SSI / CPAC. ppt Slide 2; CPAC; November 2006

Siemens Applied Automation Summary of Siemens Activities Process Gas Chromatography Ø Siemens is implementing Siemens Applied Automation Summary of Siemens Activities Process Gas Chromatography Ø Siemens is implementing a large analyzer system project Ø Owner has requested Ne. SSI Generation 2 sampling systems Ø Siemens is proposing an implementation ► Compliant with project time frame ► Based on available technology but consistent with long term Ne. SSI vision ► Cooperative with major substrate and component suppliers Siemens Update ro Ne. SSI / CPAC. ppt Slide 3; CPAC; November 2006

Siemens Applied Automation Initial Implementation “Smart” analyzers Process Gas Chromatography Siemens Maxum edition II Siemens Applied Automation Initial Implementation “Smart” analyzers Process Gas Chromatography Siemens Maxum edition II GC with integrated Ne. SSI Generation 2 Bus Control capability. Smart modular process sample conditioning implementation through the cooperation of: • Siemens • CIRCOR Instrumentation Technologies • Parker Hannifin • Swagelok I. S. Power Supply Intrinsically safe, Generation 2 Bus P V T A Sampling systems built with substrates and smart, Generation 2 - compatible components. SAM functionality is integral to the analyzer Siemens Update ro Ne. SSI / CPAC. ppt Slide 4; CPAC; November 2006

Siemens Applied Automation Initial Implementation “Dumb” analyzers Process Gas Chromatography Continuous Gas Analyzers with Siemens Applied Automation Initial Implementation “Dumb” analyzers Process Gas Chromatography Continuous Gas Analyzers with system control and network integration provided by Siemens Network Access Unit (NAU) with integrated Ne. SSI Generation 2 Bus Control capability. I. S. Power Supply Intrinsically safe, Generation 2 Bus P V T A Sampling systems built with substrates and smart, Generation 2 - compatible components. SAM functionality is external to the analyzer Siemens Update ro Ne. SSI / CPAC. ppt Slide 5; CPAC; November 2006

Siemens Applied Automation Review of Key Generation 2 Requirements Pieces Of the Ne. SSI Siemens Applied Automation Review of Key Generation 2 Requirements Pieces Of the Ne. SSI Idea Process Gas Chromatography Ø New mechanical components ► Modular ► Standardized mounting platform ► Complete; Available from a variety of suppliers. Interchangeable function Ø New electrical interconnection ► Serial connection – plug in ► Intrinsically safe ► Self-identifying components Lots of discussion. Various standards considered; none adopted. Ø New smart design features (SAM) Various implementations are possible. ► Helpful HMI ► Programmability ► Standardized, transportable user programming Siemens Update ro Ne. SSI / CPAC. ppt Slide 6; CPAC; November 2006

Siemens Applied Automation Key Bus Physical / Functional Requirements Process Gas Chromatography Sampling System Siemens Applied Automation Key Bus Physical / Functional Requirements Process Gas Chromatography Sampling System Analyzer House (typical) Note: ** Often, sampling systems are mounted separately from related analyzer. ** Some systems mounted attached to analyzer. 1. Analyzer may be up to 10 m from sampling system. Total cable length <=20 m 2. Number of bus “instances” to be limited to simplify analyzer control and reduce cost; <= 2 instances preferred, excluding power sources 3. Bus to support very large number of participating component and analyzer suppliers (unlimited ~ >1000’s) 4. Bus to provide for sensing and control of: valves, pressure, flow, temperature 5. Component power to be supplied via bus (rather than separate power bus) to simplify I. S. and physical issues Siemens Update ro Ne. SSI / CPAC. ppt Analyzer Local Power and Air Slide 7; CPAC; November 2006

Siemens Applied Automation Key Bus Physical / Functional Requirements (Continued) Process Gas Chromatography 6. Siemens Applied Automation Key Bus Physical / Functional Requirements (Continued) Process Gas Chromatography 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Components to be mounted in Division 1 / Zone 1 hazardous area. Bus to be intrinsically safe and to support components mounted in hazardous area Design goal for flammability ignition temperature to be T 4 (135°C) with minimum at least T 3 (200°C). Component ambient temperature to be >=70°C Sampling system to be capable of supporting at least 30 separate streams Bus to support at least 200 component / functional instances Bus to support component types in any combination up to the total number of components in the system. Bus to support at least 4 simultaneously active valves Bus to supply necessary component power management functions Bus to support replacement of components while live without interruption of bus operation Bus to provide for control of high-power components that do not draw power from the bus itself (eg. heaters) Note: Requirements listed in no particular order. Siemens Update ro Ne. SSI / CPAC. ppt Interior of cabinet is considered hazardous due to leakage of flammable gases in a closed area. Mounting area may be hazardous or not. Slide 8; CPAC; November 2006

Siemens Applied Automation Key Bus Requirements Functions Defined by Bus Process Gas Chromatography Method Siemens Applied Automation Key Bus Requirements Functions Defined by Bus Process Gas Chromatography Method of human interface for SAM. External communications Bus must provide a method for analyzers to get “on” the bus. Bus must provide a method for components connect “to” the bus… Analyzer SAM “SAM” may be either a physical device or a software implementation in the analyzer. P V T A Siemens Update ro Ne. SSI / CPAC. ppt Slide 9; CPAC; November 2006

Siemens Applied Automation Status of Siemens Implementation Overview Process Gas Chromatography I. S. Power Siemens Applied Automation Status of Siemens Implementation Overview Process Gas Chromatography I. S. Power Supply(ies) Media Access Controller Chip (chip spec and burn image by Siemens; assembly by component manufacturer) Siemens GC Existing I/O Link with proprietary protocol As needed… Bus buffer and I. S. barrier Intrinsically Safe Ne. SSI Generation 2 Bus Component interface electronics (by component manufacturer) Siemens Update ro Ne. SSI / CPAC. ppt Substrate Mechanical component Slide 10; CPAC; November 2006

Siemens Applied Automation Status of Siemens Implementation Process Gas Chromatography Ø Analyzer and software Siemens Applied Automation Status of Siemens Implementation Process Gas Chromatography Ø Analyzer and software ► Communications Software / Protocol: existing proprietary, complete Ø External bus ► ► Buffer / drivers and I. S. barriers: in test I. S. certification: preliminary review complete EMI / RFI testing: bus validation proven; components pending Robustness, bit error rate testing: bus validation proven; components pending Ø Components ► ► Media Access Controller chip: Version 1 operating in test Component interface and software: in test I. S. certification: pending Component functions: in test Ø Field Schedule ► ► Live demonstration at engineering facility: November 2006 Planned field delivery: 2007 Ø Compatibility with Ne. SSI Vision ► ► Direct implementation of Ne. SSI concept; meets all key requirements Architecture consistent with other Bus technologies currently being considered (CAN, Fieldbus, Profibus) Siemens Update ro Ne. SSI / CPAC. ppt Slide 11; CPAC; November 2006