SC B 5 - Protection and Automation Report to the Canadian National Committee of Cigré 2008 Simon R. Chano Protection Specialist Hydro Québec TransÉnergie 800 de Maisonneuve est, 22 ième étage Montréal, QC H 2 L 4 M 8 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie - -
CIGRÉ STUDY COMMITTEE B 5 Protection and Automation System protection v Substation control, automation, monitoring and recording including internal and external communications, substation metering systems and interfacing for remote control and metering v All technical, organisational and economical aspects are considered including staff education and training. v 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 2
The mission of B 5 Facilitate and promote the progress of engineering and the international exchange of information and knowledge in the field of protection and automation Add value to this information and knowledge by means of synthesizing state-of-the-art practices and developing recommendations. This mission can be split in two main sub-missions: Promotion of continued development and exchange of experience for safer and more effective operation of power systems To be first international reference for power system protection and substation automation issues, synthesizing state-of-the-art practices and developing recommendations 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 3
Cigré B 5 Chairman: I. De Mesmaeker Secretary: P. Hindle AG B 5 - 51 Substation Automation & remote control J M Ordacgi Filho (BR) B 5 Strategic Advisory Group AG B 5 -52 Protection & Monitoring of Main Plant & Circuits S Chano (CA) Dec. 2007 AG B 5 -53 Monitoring, metering, recording & Overall System Prot. G. J. Amantegui (ES) WG B 5 -36: Apps for prot schemes based on 61850 D. Tholomier (FR) WG B 5 -10: Protection of series compensated lines J. Zakonjsek (SE) WG B 5 -04: Tech‘s for prot. & monit gen. plant G Benmouyal (CA) WGB 5 -20: New trends for auto fault & dist. analysis M Kezunovic (US) WG B 5 -33: Acceptable func. Integr. in HV SS‘s A/ Apostolov (US) WG B 5 -15: Distance protection functions D. A. Tziouvaras (US) WG B 5 -07: Tech‘s for prot. & monit. trans. lines S Chano (CA) WGB 5 -19: Protection relay coordination H. Kameda (JP) WG B 5 -32: Func. Testing of 61850 based systems I Patriota (BR) WG B 5 -37: Prot, cont & monitoring of shunt reacs. P. Naisani (CA) WGB 5 -08: Refurbishment Strategies etc. P. Leushuis (NL) WG B 5 -31: Management of protection settings P. Crossley (UK) WG B 5 -12: Engineering guidelines for IEC 61850 based systems WG B 5 -16: Modern Techniques for BBP Z. Gajic (SE) WG B 5 -06: Maintenance strategies for SAS WG B 5 -38: Impact of security requirements D. Holstein (US) 2008 - 10 -19 WG B 5 -05: Transformer prot, monitoring & cont M. Sachdev (CA) WG B 5 -14: WA P & C Technologies Simon R. Chano, Hydro Québec TransÉnergie WG B 5 -94: High Impedance Faults I Ojanguren (ES) WG B 5 -34: Impact of renewable energy sources & dist. gen. on S/SP&A J Gonzalez (ES) WG B 5 -21: New local P&C approaches to minimise impact of system distubances A H Abu Bakar (MY) 4
B 5 Subcommittee Organization ( August 2008) SC B 5 Chair – G. J. Amantegui (ES) SC B 5 Secretary – Iony Patriota (BR) Three Advisory Groups AG 51 – Substation Automation and Remote Control: Convenor J. M. Ordacgi Filho (BR) AG 52 – Protection of main plants and circuits: Convenor S. Chano (CA) AG 53 – Metering, Monitoring, Recording and Overall Power System Protection: Convenor Richard Adams (UK) 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 5
AG 51 - Substation Automation and Remote Control WG B 5 -36 Application for protection scheme based on IEC 61850 v preparing a report – expected completion 2009 WG B 5 -08 Refurbishment Strategies based on Total Cost of Ownership, Operational Risk and Technical Constraints v preparing a final draft for distribution to SC Chairman and Secretary October 2008 WG B 5 -31 Management of protection settings v preparing a report – expected completion 2009 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 6
AG 51 - Substation Automation and Remote Control WG B 5 -12 Engineering Guidelines for IEC 61850 Based Substation Automation Systems v preparing a report after Survey is completed – expected completion 2010 WG B 5 - 06 (New WG) Maintenance Strategies for Digital substation Automation – Kick-off meeting held on March 25, 2008 WG B 5 - 38 The Impact of Implementing Security Requirements using IEC 61850 - expected completion 2009 WG B 5 - 14 (New WG) Wide Area Protection and Control Technologies - Kick-off meeting held on August 26, 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 7
AG 52 – Protection of main plants and circuits WG B 5 -04 Modern techniques for protecting and monitoring of generating plants v preparing a report – expected completion 2008 WG B 5 -05 Modern techniques for protecting, controlling and monitoring power transformers v preparing a report – expected completion 2009 WG B 5 -07 Modern techniques for protecting and monitoring of transmission lines v preparing a report – expected completion 2009 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 8
AG 52 – Protection of main plants and circuits WG B 5 -10 Protection of series compensated lines and series capacitor banks v preparing a report – expected completion 2008 WG B 5 -15 Modern applications of distance protection v Completed 2008 – Electra article will be published shortly WG B 5 -16 Modern techniques for protecting busbars in HV networks v preparing a report – expected completion 2008 WG B 5 -37 Protection, Monitoring and Control of Shunt Reactors v preparing a report – expected completion 2010 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 9
AG 53 – Metering, monitoring, recording and overall power system protection WG B 5 -19 Protection relay coordination v report presented to SC in Paris 2008 – Almost complete WG B 5 -20 New trends for automated fault and disturbance recording and analysis v preparing a report – expected completion 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 10
AG 53 – Metering, monitoring, recording and overall power system protection WG B 5 -34 The Impact of Renewable Energy Sources and distributed Generation on Substation Protection and Automation v preparing a report – expected completion 2009 WG B 5 -21 New local protection and control approaches to minimize the impact of system disturbances v Difficulties due insufficient input – expected completion XX TF B 5 -94 High impedance faults v Report is ready and presentation was done in August 2008 – expected completion 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 11
ACCOMPLISHED WORK WG B 5 -11 The introduction of IEC 61850 and its impact on protection and control within substations: Published 2007 WG B 5 -13 Acceptable functional integration in HV substations v Final Draft was submitted in May 2008 Along with Electra Summary WG B 5 -32 Functional Testing of IEC 61850 Based Systems v Final Draft was submitted in 2008 with Electra Summary paper WG B 5 -15 Modern applications of distance protection v Final Draft was submitted in 2008 with Electra Summary paper WG B 5 -03 Fault and Disturbance data Analysis including intelligent systems v Published end 2007 with Electra paper WG B 5 -94 High impedance faults v Document sent to officers for approval 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 12
Newly Formed WG (2007) WG B 5 -37 Protection, Monitoring and Control of Shunt Reactors preparing a report – expected completion 2010 WG B 5 - 06 Maintenance Strategies for Digital substation Automation – Kick-off meeting held on March 25, 2008 WG B 5 - 38 The Impact of Implementing Security Requirements using IEC 61850 WG B 5 - 14 Wide Area Protection and Control Technologies - Kick-off meeting held on August 26, 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 13
Newly Formed WG (2008) WG B 4/B 5. 25 Impact of HVDC Stations on Protection of AC Systems – Canada will propose a regular member Document the different HVDC technologies and their different ac side performance during steady state, dynamics and transients. Discuss user experience of Protection systems in existing substations near HVDC projects. Discuss impact of HVDC control and protective functions on AC protection including the overall coordination issues. Determination of the impact by an HVDC scheme on short-circuit current, cross country faults (faults between ac and dc lines), islanding issues, sub-synchronous resonance and transient parameters including dynamic / transient voltage and commutation failure which may result in tripping of AC lines. Discuss the effect of DC ground current through AC networks in all modes of HVDC operation. Establish the method of calculating parameters to be used for HVAC protections in the presence of HVDC schemes. Propose an amendment of IEC 909, which at present does not take into account these aspects. Provide models which can be useful for protection settings. 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 14
Newly Formed WG (2008) JWG B 5/D 2 -XX Application Guide on Digital Inter- Station Communication for Protection- Canada will propose a corresponding member Scope : 1. Elucidate the problems faced when modern teleprotection and communication equipment do not function together. 2. Development recommendations on how to interpret relevant standard in the field. 3. Specify the communication requirements for protection signaling over telecommunication networks. Suggest recommendations and guidelines for correct performance of the telecommunication with reference to protection requirements. 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 15
Newly Formed WG (2008) WG B 5. 22 Standardised Protection Schemes - Canada will propose a corresponding member Scope: Investigate what are the main drivers for a utility to adopt or a contractor to produce/apply a standardised design philosophy? . Assess and quantify the cost to produce and approve the scheme initially compared to a bespoke design? . What is the cost benefit to each circuit once the design is finalized compared to a bespoke design? . Establish a recommended period of time that the standard scheme should be applied for before it is revised, in order to realise the benefits expected whilst not allowing technology to move to far ahead during this period. Identify any barriers to the implementation of standardised protection schemes – is voltage level a factor here or are utility structure and policies the main obstacles? Investigate whether standard interfaces between primary and secondary equipment can be established to enable different manufacturer’s standard schemes to be applied with ease. 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 16
Newly Formed WG (2008) WG B 5. 23 Protection of hybrid line/cable circuits in transmission networks – Canada will propose a regular member Background: Overhead transmission lines and HV underground AC cables including GIL have different electrical characteristics. Shield grounding methods significantly affect the zero-sequence impedance of underground cables. In many cases, it is very difficult to assess the precise cable parameters during unbalanced faults due to different ground return paths. This WG is formed to identify complex issues that impact the transmission lines/cables. 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 17
Newly Formed WG (2008) WG B 5. 24 Protection Requirements on Transient Response of Voltage and Current Digital Acquisition Chain - Canada will propose a corresponding member Background: The introduction of Station Bus within international station communication standard IEC 61850 -9 -2 makes possible use of different products (primary and secondary) from a number of different vendors to form digitized instantaneous value of a measured quantity (voltage and or current) intended for further processing in different protection, control and monitoring algorithms within different IEDs. Static accuracy of a complete measuring chain is well defined by different IEC and other standards while lack in definition of dynamic response represents a potential danger for required high availability of protection functions. It is supposed that transient response of conventional instrument transformers is well known and defined by existing international standards. For this reason, it is necessary to determine the minimum requirements on transient response of a complete signal processing chain, including first of all Merging Units and Non-conventional Instrument Transformers. 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 18
PREFERENTIAL SUBJECTS (2007) Madrid, Spain October 15 to 20, 2007 v Highlights: PS 1: New Trends on Bus Bar Protection v PS 2: Acceptable Functional Integration in Substation P&C for Transmission Systems v PS 3: Protection of Transmission Lines & Coordination of Transmission System Protection v 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 19
PREFERENTIAL SUBJECTS (2008) Highlights: Special Report for Preferential Subject 1 : Impact of process-bus (IEC 61850 -9 -2) on protection and substation automation systems Special Report for Preferential Subject 2 : Life Cycle Management of Protection and Control Systems 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 20
PREFERENTIAL SUBJECTS (2009) Highlights: Strategies for the Lifetime Maintenance of SAS Systems (new WG) Protection & Control of FACT devices and impact on Protection Systems Wide Area Monitoring, Control & Protection Technologies 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 21
PREFERENTIAL SUBJECTS (2010) Highlights: Protection Control & Monitoring Beyond 2015 – Allocation of P&C functions - Architecture of SAS – New concepts – New requirements – Recording Impact of renewable generation and cogeneration on Substation automation and Protection : • Protection coordination • Connection & generator protection requirements • Automation and restoration policies • Islanding detection • Future trends on protection and automation 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 22
TUTORIAL SUBJECT FOR 2009 Experience in the protection of circuits & multi-terminal lines and power transformers 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 23
Canadian participation Leadership roles v v v Simon Chano (HQ) Ø B 5 Canadian Representative Ø B 5 -52 Advisory group member Ø Convenor WG B 5 -07 Ø Secretary WG B 5 -15 Ø Corresponding member WG B 5 -19 Ø Corresponding member B 5 -05 Gabriel Benmouyal (SEL) Ø Convenor WG B 5 -04 Pouria Naisani (AREVA) Ø Convenor WG B 5 -37 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 24
Canadian participation Leadership roles Mohindar S. Sachdev (U of Saskatchewan) Ø Convenor WG B 5 -05 Ø Member WG B 5 -07 Ø Member WG B 5 -15 v Brian Sparling Ø Corresponding Member WG B 5 -05 v Dr Jian-cheng (JC) TAN (Kinectrics Inc) Ø Member WG B 5 -38 v 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 25
Canadian participation Leadership roles Bogdan Kasztenny (GE Multilin) Ø Member WG B 5 -12 v John Robertson (British Columbia Transmission Corporation) Ø Member WG B 5 -06 v John Ciufo (Ontario Hydro) Ø Member WG B 5 -14 v Marc Lacroix (Hydro Québec) Ø Corresponding Member WG B 5 -38 v 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 26
List of Members – Canadian Forum Canadian Representative / Représentant canadien Simon Chano chano. simon@hydro. qc. ca Members of the Discussion Forum / Membres du forum d'échanges Bogdan Kasztenny, Bogdan. Kasztenny@ge. com John Ciufo, john. ciufo@Hydro. One. com Michel Langlois, Eng. michel. langlois@snclavalin. com Marc Lacroix, lacroix. marc@hydro. qc. ca Daniel Wong daniel. wong@altalink. ca John Robertson john. robertson@bctc. com Tarlochan Sidhu sidhu@eng. uwo. ca Frank P. Plumptre f. plumptre@ieee. org 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 27
Concluding Remarks Study committee actively examines protection and automation issues Discusses the issues and provides reports on those issues Promotes power engineering education Conducts tutorials at the SC meetings B 5 tries to get participation from utility engineers, consultants and academia 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 28
Web site SC address : web site is http: //www. cigre-b 5. org Pour information additionnelle /For additional information, me contacter/you can contact me: Chano. simon@hydro. qc. ca 2008 - 10 -19 Simon R. Chano, Hydro Québec TransÉnergie 29