f76a7847c076ccbbc028e42c63a87e08.ppt
- Количество слайдов: 9
Reference Thermometers Features & Benefits n CPT 1000 n Platinum Resistance n CPT 2000 n Platinum Resistance n CPT 9000 n Thermocouple n CED 7000 & others n Signal calibrators
Reference Thermometer CTP 1000 PLATINUM RESISTANCE THERMOMETER ØMeasuring range -100 to 670 o. C ØStability better than 40 m. K after 100 h at 660 o. C ØDimensions: Ø 6. 35 mm, l= 450 mm Ø 4 -wire connection, ends stripped and tin-coated Data Sheet CT 61. 10…
Reference Thermometer CTP 2000 PLATINUM RESISTANCE THERMOMETER ØMeasuring range -200 to 450 o. C ØStability better than 50 m. K after 100 h at 450 o. C ØDimensions: Ø 6. 35 mm, l= 450 mm Ø 4 -wire connection, ends stripped and tin-coated Data Sheet CT 61. 10…
Reference Thermometer CTP 9000 THERMOCOUPLE ØMeasuring range: 0 – 1300 o. C ØThermocouple: Type S; Class 1 ØDimensions: Ø 7 mm, l = 1500 mm Ø 450 mm cable, ends with 4 mm connector Data Sheet CT 61. 10…
Temperature Reference thermometer Model CTP 1000 CTP 2000 CTP 9000 Range -100 … +670 °C -200 … +450 °C 0 … +1300 °C Pt 100 resistance Thermocouple Type S Ø 6, 35 mm, l = 450 mm Ø 4 mm, l = 500 mm Ø 7 mm, l = 1500 mm Elements Dimensions Features -4 -wire connection -ends stripped and tin-coated -4 -wire connection, -ends with 4 mm connector -With cold junction available - ends with 4 mm connector Suitable measuring devices: CEP 6000 and CEP 6100 Calculation of coefficients possible and necessary Calibration at an accredited laboratory
Temperature Hand- Helds portfolio Model CTH 6200 CTH 6500 Starter Range CEP 3000 Starter Medium TC (11), RTD (11), Ohms -50…+250°C -55. . . +480°F -200…+1500°C -325. . . +2730°F Pt 100, TC, (humidity, flow) Elements Accuracy Display Features 7 ± 0. 4 °C for J T/C all errors included ± 0. 3 °C for PT 100 RTD 0. 05… 0. 2 K 0. 1 °C Simulate and measure 0. 03 K RTD 0. 2 K TC 0. 01°C up to 200°C, then 0. 1°C datalogger -Datalogger optional - 2 channel version optional - Ex version optional
Signal Calibrator Hand-Helds Portable Multi-Function Calibrator CEP 6000 / CEP 6100 § Range: resistance thermometers(13), thermocouples (13), resistance, current, voltage, frequency, pressure § Accuracy: 0. 015 % rdg (m. A, V) § CEP 6100 with calibration function Applications:
Signal Calibrator Hand-Helds Documenting CEP 6100 § Store up to 50 different UUT to CEP 6100 § Print certificate on site § Store certificate on PC § Calculates deviation for you
High-precision process calibrator CED 7000 ØMeasuring range 0… 100 m. A, 0… 100 V, 5… 4000Ω, -210…+1200⁰C (type J), -200… +800 ⁰C (Pt 100) ØAccuracy : 0. 003% ØMeasurement and simulation of thermocouples, resistance thermometers, resistance, current, voltage and pressure Data Sheet CT 85. 51…