Скачать презентацию Precedent Analysis arc 572 UT Solar Decathlon 2009 Скачать презентацию Precedent Analysis arc 572 UT Solar Decathlon 2009

22760c51318635d32c772ce3f04fa2fa.ppt

  • Количество слайдов: 11

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability "Ripple House" – 3 rd place

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability Architecture - 18 th place

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 floor plan : 650 ft 2 + 1200 ft 2 deck ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability living room/kitchen hall bathroom bedroom mechanical

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 Foundation: free-standing steel stands ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 Floor framing: 2 x 10's @ 16" O. C. ; double 2 x 10's @ 8" O. C. under mechanical room ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 Wall framing: 2 x 6 studs @ 16" O. C. ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 Roof framing: engineered bamboo I-joists @ 2' O. C. ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 Roof: sprayed-on polyurethane insulation with acrylic waterproofing ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability James Hardie fibercement siding Richlite compressed paperboard Electrochromic windows Nana-wall : triple-pane low-E glass

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability Engineering - 10 th place Engineered bamboo I-joists Sun. Power SPR-215 photovoltaic panels Automated, remotely-accessible computer controls

Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University Precedent Analysis arc 572 UT Solar Decathlon 2009 “Designing with Purpose” Santa Clara University | 2007 ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture materials comfort zone getting around engineering appliances energy balance communications lighting hot water market viability Bamboo finishes Recycled ceramic tile Water-based paints Organic latex foam Hemp upholstery Smart appliances Compact fluorescents / LEDs