Out sourcing your hydrologic data collection system design, install, monitoring, notifications, and maintenance David Out sourcing your hydrologic data collection system design, install, monitoring, notifications, and maintenance David C. Leader, P. E. Hydro. Lynx Systems Markus L. Ritsch, P. E. Water & Earth Technologies, Inc.

The need Ø Hydrologic monitoring and warning system Ø Design of sites and telemetry The need Ø Hydrologic monitoring and warning system Ø Design of sites and telemetry Ø Man power for installation Ø Location for base station Ø Automated monitoring and warning Ø Maintenance of remote sites and base station data.

The place Panama The place Panama

The challenges Ø Jungle location far from existing telemetry networks Ø Intense rainfall and The challenges Ø Jungle location far from existing telemetry networks Ø Intense rainfall and out of bank flooding is common Ø Local maintenance personnel not available Ø Local base station monitoring personnel not available

Install stations in the jungle Install stations in the jungle

The solution Ø Design and install a near real-time hydrologic warning network in 5 The solution Ø Design and install a near real-time hydrologic warning network in 5 watersheds

Design for high water overbank Design for high water overbank

Heavy rain, quick river rise Heavy rain, quick river rise

Install radar sensor over river Install radar sensor over river

Discharge computed by database rating tables Discharge computed by database rating tables

Water quality sensor in river is protected by conduit Water quality sensor in river is protected by conduit

Water quality data on Google map display Water quality data on Google map display

Mount on bridges when available Mount on bridges when available

Data delivery to database hosted by WET Ø Hydro. Lynx data logger and satellite Data delivery to database hosted by WET Ø Hydro. Lynx data logger and satellite telemetry Ø 15 minute samples Ø 1 hour transmission

Data reports on internet database Data reports on internet database

Data on Google maps Data on Google maps

Trigger sampler at high water Ø Event transmission when sampler triggered Trigger sampler at high water Ø Event transmission when sampler triggered

Sampler triggered at high water Sampler triggered at high water

Email notification by alarm triggers Ø Customer notified for sampler triggers Ø WET personnel Email notification by alarm triggers Ø Customer notified for sampler triggers Ø WET personnel notified for maintenance alarms

Large battery array extends life between maintenance visits Large battery array extends life between maintenance visits

Monitor battery level at base station Monitor battery level at base station

Remote site maintenance Ø WET technicians do remote station maintenance every 6 months to Remote site maintenance Ø WET technicians do remote station maintenance every 6 months to insure the best data quality and continued performance of the system

Base station maintenance Ø The Nova. Star 5 server database was setup by HYDROLYNX Base station maintenance Ø The Nova. Star 5 server database was setup by HYDROLYNX and WET engineers Ø WET engineers provide server maintenance to insure the continuous collection, validation, access, and notification of the remote data

Problem solved Ø The customer’s hydrologic data and notification needs are met without any Problem solved Ø The customer’s hydrologic data and notification needs are met without any man power other than contract maintenance Ø Thank you