National Data Buoy Center NDBC Real Time Wave Data Processing and QC/QA Chung-Chu Teng National Data Buoy Center Stennis Space Center, MS 39529, USA Chung-Chu. Teng@noaa. gov
National Data Buoy Center NDBC Wave Stations 88 buoys (28 directional waves) and 4 C-MAN stations
National Data Buoy Center NDBC wave measurement capabilities Non-directional waves Directional waves 3 -m, 10 -m discus buoys Yes (all) Yes (28) 6 -m NOMAD buoys Yes (all) Plan to use a supplemental directional wave buoy C-MAN (in water) Yes (4, not very reliable) Plan to use COTS wave sensors or a directional wave buoy C-MAN (on land) -- Plan to use a directional wave buoy
National Data Buoy Center C-MAN Wave Measurements Chesapeake Light Diamond Shoal St. Augustine
National Data Buoy Center Buoy Wave Measurements 3 -m discus buoy 10 -m discus buoy 6 -m NOMAD buoy
New Stand-alone Wave System/Buoy National Data Buoy Center Directional Wave Measurement System: - Small & light - Low power consumption - Low cost - Built-in transmitter - Standalone - Configurable Directional Wave buoy: - Small & light, deployable from small vessels - Low cost - Low maintenance 1. 8 m COLOS buoy
National Data Buoy Center NOMAD Directional Wave Measurements Use a small directional wave buoy (tether to a 6 -m NOMAD buoy or stand-alone) GOES or Iridium RF/LOS communication
C-MAN Wave Measurements National Data Buoy Center GOES or Iridium RF/LOS communication Deploy a standalone directional wave buoy Install a fixed directional wave sensor on the structure
National Data Buoy Center Nondirectional wave data • Wave energy spectrum S(f) • Wave parameters: Frequency, f Peak (or dominant) wave period, Tp Mean (or average) wave period, Tz or Ta Significant wave height, Hs
Buoy Wave Measurement National Data Buoy Center Ocean waves Buoy hull motions Measurements (Sensors) Onboard processing Transmission (or storage) Shoreside processing Wave data
Nondirectional wave data from buoys National Data Buoy Center From buoy motion to wave data Sh(f): spectrum of buoy heave motion Sw(f): wave spectrum (acceleration) PTF: power transfer function From acceleration to displacement spectra
National Data Buoy Center Noise Correction S(f) Low-frequency noise Frequency (f)
National Data Buoy Center NDBC directional wave buoy systems • Based on the “slope following” principle • Can only use axis-symmetrical buoys • Buoy pitch and roll information are required to determine directional wave data
National Data Buoy Center Directional wave algorithm (1) f : wave frequency; 2 : wave direction K: the wave number C and Q : co- and quad-spectra 1: vertical motion (heave) 2: N-S slope (pitch) 3: W-E slope (roll)
National Data Buoy Center Directional wave algorithm (2) θ 1 and θ 2: mean and principal wave directions r 1 and r 2 : directional energy spreading
National Data Buoy Center Configurations of NDBC directional wave systems • HIPPY – a gimbaled gyro system that measure pitch and roll directly • MO – use only magnetometer outputs to estimate buoy pitch and roll • ARS – derive buoy pitch and roll from angular rate sensors
National Data Buoy Center NDBC Wave Systems • • • DACT Wave Analyzer (WA) DACT Directional Wave Analyzer (DWA) VEEP Wave Analyzer (WA) Wave Processing Module (WPM) Directional Wave Processing Module (DWPM) • Non-Directional Wave Processing Module (NDWPM) • Directional Wave Measurement System (DWMS)
National Data Buoy Center General Principles for Data QA/QC • Reasonability: Data should be in reasonable ranges and intervals. • Continuity: Data should maintain the continuity in time and space. • Consistency (or correlation): Data should have proper time correlation, spatial correlation, and correlations with other measurements.
National Data Buoy Center Some wave data QC techniques • • • Range check Time continuity Internal consistency (e. g. , QMEAN) Wind vs. wave energy (wind-wave algorithm) Swell direction check High frequency spectral spikes, Wave height vs. average wave period Wave direction vs. wind direction (> 0. 35 Hz) When needed, wave data from NCEP’s wave models and other organizations will be used to check its buoy wave data.
National Data Buoy Center Hard Flags (by hierarchy - highest to lowest) • T Transmission parity error (Applies to continuous winds and non-WPM wave data) • M Missing sensor data (A result of a garbled or missing message). • W A WPM wave message is short, missing a checksum, or parity errors are detected. • E Calculation limits are exceeded or are in error (waves only, flags WVHGT). • D Delete measurement from release and archive (A Data Analyst or automated QC has failed the sensor). • S Invalid statistical parameter (in waves, QMEAN is not between QMIN and QMAX, flags WVHGT). • V Failed time continuity. • L Failed range limits. • H Hierarchy reversal has occurred (BARO, WSPD, WDIR only). • R A related measurement has failed a hard QC check.
Soft Flags (in alphabetical order) National Data Buoy Center • • • • • • a Measurement is above monthly, regional limit. b Measurement is below monthly, regional limit. c Measurement has been adjusted, or corrected (applies to DEWPT and WVHGT, DOMPD and AVGPD). d Failed standard deviation test (continuous winds only). f Measurement failed hourly time continuity. g Failed gust-to-mean wind speed ratio (applies to standard and continuous winds). i Continuous and hourly wind speeds don’t agree. j One, and only one, transmission error detected in the continuous wind string of a GOES message (all continuous wind measurements are flagged, if more than one error detected, than flag is upgraded to a T flag). k Difference between duplicate measurements is too high. m High frequency spikes detected in the wave spectrum (C 11), WVHGT is flagged. n Measurement failed comparison with NCEP model fields. p Failed wave height to wave period comparison test. q Swell direction is from an improbable direction. r Related measurement failed (continuous winds only). s Stuck raw compass ( RCOMP and WDIR are flagged). t Tendency difference between duplicate sensors is too high. v Failed relative humidity verses visibility check. w Failed wind direction verses wave direction check. x Wind wave energy is too high for prevailing wind speed. y Wind wave energy is too low for prevailing wind speed. z Failed bow azimuth verses wind direction check.
National Data Buoy Center NDBC Technical Document 03 -02 Handbook of Automated Data Quality Control. Checks and Procedures of the National Data Buoy Center February 2003 National Data Buoy Center Stennis Space Center, Mississippi 39529 -6000
National Data Buoy Center Range check (wave height) Previous EQC limit: 5. 2 m (Lakes Erie and Huron) New EQC limit: 7. 5 m
National Data Buoy Center Range check (wave period)
National Data Buoy Center Increasing QMEAN
National Data Buoy Center Hurricane Ivan - Significant wave heights
National Data Buoy Center Significant wave height during Ivan
National Data Buoy Center Wind and wave directions
National Data Buoy Center Wind-wave algorithm
National Data Buoy Center How is your wave measurement?
National Data Buoy Center We always improve our systems and DQC/QA process so we can get more accurate wave measurement