a5e04a1711e058d03a3ea6a05eb0799e.ppt
- Количество слайдов: 25
Moxa Embedded Solution on IEC 61850 Moxa Systems August, 2009
Theme n IEC 61850 with Smart Grid n Substation Automation Empowered By IEC 61850 n Moxa Solution n Summary Confidential
Future of Power: Smart Grid n Everything is now based on electricity • Computers, Networks, Telecom, Medical, … n Electric grid produces at least 40% of CO 2 emissions n Aging electric grid contributes a 20% power loss while delivering to end user Confidential
Smart Grid Infrastructure Substation Automation Advanced Metering Infrastructure Power Generation Electricity Dispatching Control Center Customers Transmission Distributed Energy Integrated Source: EPRI Intelligrid Confidential
Substation Automation in Smart Grid Electricity consumption, switchboard operation, information gathering, station decision making feedback Electricity Dispatching Control Center Substation Grid intelligence strategic decision, T&D automated management Source: EPRI Intelligrid Confidential
Current Power Automation Protocols DNP 3. 0 IEC 60870 -5 DNP 3. 0 Mod. Bus Confidential
Protocol Trend for Power Automation Newton Evans: 2005 -2007 n IEC 61850 is the trend n Migrating to Ethernet-based Confidential
Future Power Automation Protocols DNP 3. 0 LAN IEC 60870 -5 IEC 61850 DNP 3. 0 LAN Mod. Bus/TCP Confidential
Substation Automation Empowered By IEC 61850 Confidential
Benefits of IEC 61850 Power Substation Protocol Integration Easy Maintenance IEC 61850 Confidential Time to Market
Moxa Offering Confidential
Moxa Embedded Solution Confidential
Lead with IEC 61850 -3 Certified Embedded Computer – DA-681 PASS! DA-681 -I-DPP-T IEC 61850 -3 Test Confidential
Using DA-681 in IEC 61850 -3 Substation n Requirements • IEC 61850 -3 certified hardware • Multiple LANs to connect IED device and communicate dispatch control center • Requires 100 -240 AC/DC power input • 19 -inch rackmount, fanless design n Benefits • The DA-681 has 6 LANs for network redundancy and centralized communication • Excellent patented heat dissipation design for use in • -40 ~ 75˚C environments • Serial port with isolation protection for integrating legacy RTU into IEC 61850 substation • Dual power design to connect simultaneously to 100 VDC and 240 VAC power sources Confidential
Features Briefing n Intel x 86 1 GHz CPU with 910 GMLE chipset n Built-in DDR 2 SDRAM and industrial-grade DOM n 19 -inch rackmount installation, 1 U high n 6 Ethernet ports for network redundancy n 2 USB 2. 0 Host, supporting system boot up n 4 Serial 232 & 8 RS-485 ports (wide baud rate) n CF/SATA interfaces for storage expansion n 100 to 240 V AC/DC power input n Dual power for redundant application (DP/DPP model only) n Fanless and low power consumption design Confidential
Challenges to Certify IEC 61850 -3 Function Test EMC Test Wide Temperature Test Anti-Vibration Test Confidential
Unique Design to Conquer EMC Test Confidential
Wide Temperature Know-How Thermal Placement Optimization of Components Natural-Convection Chamber to Test Wide Temperature Components Database Optimal Heat Transfer Methods Self Warming System Confidential
Special Heat Dissipation Design L-Type for Heat Dissipation Confidential
System Throttling Design High Temperature Solution: Dynamic Throttling Technique Saf e User Configurable inside BIOS time Confidential
120 hours Uninterrupted Testing Confidential
Production Quality Management (Dynamic Burn-in) High temp. (55~75 dc) Room temp. (30~40 dc) Wide temp. (-40~85 dc) Pilot Run 24~48 hrs Mass Production 4~24 hrs W/T Product screen 24 hrs • Over 80% function test items are covered during burn-in test program. • Monitoring programs control the entire burn-in status, and show the data for analysis. Confidential
Anti-Vibration Tolerance Test 50 G Anti-Shock 5 -500 MHz Anti-Vibration Confidential
Summary n IEC 61850 is the trend in modern power substation to integrate different standards in Relay, Control, and Metering equipments n DA-681 is the best solution to fit in “Communication Processor” and “Back-end Host” Confidential
Thanks! Confidential
a5e04a1711e058d03a3ea6a05eb0799e.ppt