Maintenance free batteries
ABOUT THE EMU COMPANY • One of the largest suppliers of VRLA batteries and cells in the Central and Eastern Europe; • We deliver VRLA batteries and cells, and battery packs, among others EUROPOWER® and also ACUMAX ®, ALARMTEC, KOBE and DYNASTY; • 24 years of experience in the field of emergency power supply (since 1991); • More than 10 000 clients; • 8 million batteries sold; • Activity area: Poland, Czech Republic, Slovakia, Finland, Russia, Lithuania, Latvia, Belarus, Ukraine, Germany, Moldova, Bulgaria; • Head Office in Gdansk and branch office in Warszawa; • Quality management system: ISO 9001: 2008;
EMU – product and service offer • Batteries and cells, AGM and gel technologies, voltage: 2, 6 and 12 [V], capacity range from 0, 8 to 3000 [Ah], design life from 5 to 18 years, • Battery packs, • Battery accessories - battery racks and cabinets in any color, switches, cabling, terminal covers etc. , • Battery testers, • Installation and service at the customers, • Selection of batteries for particular applications, • Utilization of used-up batteries, • Technical support.
APPLICATIONS OF VRLA BATTERIES Buffer/stand-by operation (emergency power supply) –the battery is connected all the time to the charging system and is the emergency power source in case of a mains failure (UPS units, alarm systems, emergency lighting, telephone exchanges, fiscal cash registers, etc. ).
APPLICATIONS OF VRLA BATTERIES cyclic operation – the battery is the main power source for a device and after having been discharged it is disconnected from the load and recharged (portable and mobile equipment).
BATTERY CONSTRUCTION - AGM safety valves lid cover terminals housing negative plate positive plate
BATTERY CONSTRUCTION - GEL safety valves lid cover terminals housing negative plate positive plate
EUROPOWER® batteries
EUROPOWER® – product offer On the market since 1998. 20 series are available at present: • EH series – design life of 5 years, voltage of 12 [V], capacity from 7 to 230 [Ah], suitable for buffer as well as cyclic operation, • EP series – design life of 6 -9 years, voltage of 6 and 12 [V], capacity from 1, 2 to 17 [Ah], suitable for buffer as well as cyclic operation, • EV series - design life of 6 -9 years, voltage of 12 [V], capacity from 5 to 75 [Ah]. Designed especially for operation in UPS units. With standard overall dimensions they have a larger capacity and much better characteristics of constant power discharge, especially for short discharging times (5 -20 min). • EPS series - design life of 10 -12 years, voltage of 6 and 12 [V], capacity from 26 to 230 [Ah], suitable for buffer as well as cyclic operation, • EPL series - design life above 12 years, voltage of 6 and 12 [V], capacity from 7, 2 to 210 [Ah],
EUROPOWER ® – product offer • EPL FT, EPL FTN (AGM) and EPL FTNG (GEL) series – these are front terminal batteries with the design life exceeding 12 years, designed especially for buffer operation in 48 VDC system, suitable for installing in 19” and 23” cabinets. The EPL FTN series features as a standard a Central Degassing System (SCO), and its front terminals make possible easy and quick mounting as well as servicing. • UPS series – design life of 10 -12 years, voltage of 12 [V], capacity from 53 to 108 [Ah], • EXL, EXL N (AGM) and EXL NG (GEL) series - design life of 15 years, voltage of 2 [V], capacity from 100 to 3000 [Ah], designed for buffer operation in systems requiring long run times and high load currents. • EC series – batteries with the voltage of 12 [V] and capacity from 7 to 100 [Ah], designed especially for cyclic operation (repeated discharge/charge cycles). They withstand up to 50% more cycles than batteries of EP series with the same overall dimensions and capacities.
EUROPOWER® – product offer • EVC series – design life of 6 -9 years. Characterized by excellent efficiency both in buffer and in cyclic operation as a basic source of power for portable equipment and electric vehicles. The EVC series combines merits of EV and EC series. • EGR, EGC and EGS series – design life of 10 -12 years. The batteries are made in the gel technology. . Designed for operation under extremely severe conditions, such as high ambient temperature or long-time and deep discharging. They are suitable both for buffer and for cyclic operation. • OPz. V series – designed life above 18 years at 25 OC. 2 V cells made in the gel technology, with the positive plate of tubular (armored) construction. Designed for deep discharging. Withstand up to 1700 repeated discharge/charge cycles at a discharge depth of 80%. • EPz. B and EPz. S series – 2 V traction cells made in the liquid electrolyte technology with the armored positive plate. Dedicated for operating in fork-lift trucks and other electric motor driven vehicles.
EUROPOWER – real life 0 3 6 9 Diagram illustrating the actual life of EUROPOWER EPL series batteries and cheap equivalents available on the market. Years
WHY EUROPOWER ? • adjustment to the needs possible – wide range of more than 120 models • real lifetime more than 2, 5 times longer than that of cheap products • very high repeatability of parameters – owing to adoption of 24 quality control stations in the production process • lower maintenance costs achieved owing to the reliability and long actual life • warranty for even up to 5 years • less waste - less harmful to the environment • technical support by experienced professionals
ACUMAX batteries
ACUMAX - product offer 9 series are available at present: • AM series – design life of 6 -9 years, voltage of 6 and 12 [V], capacity from 0, 8 to 17 [Ah], suitable for buffer as well as cyclic operation, • AV series – design life of 6 -9 years, voltage of 12 [V], capacity from 9 to 22 [Ah], • AML series – design life of 10 -12 years, voltage of 12 [V], capacity from 26 to 200 [Ah], suitable for buffer as well as cyclic operation, • AFT series - these are front terminal batteries with the design life of 10 -12 years, designed especially for buffer operation in 48 VDC systems, suitable for installing in 19” and 23” cabinets, capacity from 55 to 180 [Ah], • AXL series – design life of more than 12 years, voltage of 2 [V], capacity from 100 to 3000 [Ah], designed for buffer operation in systems requiring long run times and high load currents.
ACUMAX - product offer • AMG series – design life of 10 -12 years, voltage of 6 and 12 [V], capacity from 17 to 200 [Ah]. All-purpose series designed for cyclic operation under severe conditions, such as a high ambient temperature, deep discharging and high number of cycles, and also for buffer operation (emergency power supply). • ACG series - design life of 10 -12 years, voltage of 12 [V], capacity from 24 to 70 [Ah]. Batteries designed mainly for deep discharging in cyclic operation and at an increased ambient temperature. • AFTG series – - these are front terminal batteries with the design life of more than 12 years, designed especially for buffer operation in 48 VDC systems, suitable for installing in 19” and 23” cabinets, capacity from 70 to 158 [Ah], • AXG series - design life of more than 12 years, voltage of 2 [V], capacity from 100 to 3000 [Ah], designed for buffer operation in systems requiring long run times and high load currents.
WHY ACUMAX ? • adjustment to the needs possible – wide range of more than 80 models • real lifetime more than 2 times longer than that of cheap products • high repeatability of parameters • very advantageous price to quality ratio • less waste- less harmful to the environment • technical support by experienced professionals • EXCEPTION ON THE MARKET! – before shipment – voltage and internal resistance measurement for each battery
ALARMTEC - application • alarm and fire - fighting systems • emergency lighting • fiscal cash registers and printers • telephone exchanges • emergency power supply for automatics and protection systems
ALARMTEC - product offer BP series: • design life of 5 years, • voltage of 12 [V], • range of battery capacities from 1, 2 to 65 Ah
WHY ALARMTEC? • real lifetime up to 50% longer than that of cheap Asiatic products • attractive price • manufacturer’s ISO 9001 / 14001 • technical support by experienced professionals
Battery Packs - product offer • Li-ion, Li-Po – Lithium polymer, Li. Fe. PO 4 -lithium ferroposphate, Ni. MH – nickel metal hydride or lead-acid technology • Conections – series / parallel • Cylindric and prizmatic cells • Capacities customized to client needs
Battery Packs - application • Cash registers & fiscal printers • Power tools • Measurment Devices • Wireless desk phones • Laboratory equipment
WHY Battery Packs from EMU? • 15 years experience in battery pack produce • Flexibility • Reliability • 100% quality control
CERIFICATES
i. PDA - Interactive Program for Online Selection of Batteries • • select batteries for a guaranteed power system based on the input parameters of the system, determine with great accuracy the battery run time in your device or in a guaranteed power system, generate a chart of constant power or constant current discharge for any time interval selected, make and compare discharge charts for any batteries, find any battery model interesting to you, select cabling and electric protections, examine the battery capacity available at different ambient temperatures, • generate in PDF format the results obtained
REFERENCES EUROPOWER® batteries are used among others in high power UPS units at : - Stock Exchange in Warszawa, for 4 x 160 k. VA 264 pcs of EPS 100 -12, - BPH Bank Head Office in Kraków, for 3 x 160 k. VA 192 pcs of UPS 12 -110, - TVN Warszawa, for 4 x 220 k. VA - 128 pcs of EP 230 -12, - GE Money Bank in Gdańsk, for 2 x 250 k. VA 128 pcs of EPL 150 -12, - BGŻ Bank Head Office in Warszawa, for 3 x 100 k. VA 90 pcs of EP 90 -12, - PSE Konstancin Jeziorna - 1200 pcs of EPL 28 -12, server room in Warszawa, for 34 x 200 k. VA 1360 pcs of EPL 210 -12, - T-Mobile Warszawa (see the pictures), 4 x 160 k. VA i 3 x 300 k. VA – 320 pcs of EPS 100 -12, 240 pcs of EPS 200 -12 - Orange (Telekomunikacja Polska) Warszawa - 60 pcs of EPL 210 -12, Ergo Arena Gdańsk, for 60 k. VA - 62 pcs of EPS 65 -12,
REFERENCES - Keiper Polska Świebodzin, for 2 x 300 k. VA - 80 pcs of EPS 230 -12, - Netia Warszawa, for 160 k. VA - 96 pcs of EPS 100 -12, - Hospital in Jelenia Góra, for 200 k. VA - EPS 200 -12, 40 pcs, - Wisła Kraków stadium, for 2 x 400 k. VA – EPS 200 -12, 80 pcs, - KWP Katowice, for 60 k. VA - 88 pcs of EPS 200 -12, - ZUS Szczecin, for 300 k. VA - 64 pcs of EPL 150 -12, - Staszów hospital, for 200 k. VA - 117 pcs of EPS 200 -12, - Kredyt Bank Warszawa, for 6 x 80 k. VA - 192 pcs of EPS 120 -12, - KGHM, for 60 k. VA - 64 pcs of EPS 200 -12, - Tivoli Park Warszawa, for 3 x 30 k. VA - 120 pcs of EPS 200 -12, - CMI Gdańsk (see the pictures), for 240 k. VA and 3 x 120 k. VA – 40 pcs of EPS 230 -12 and 297 pcs of EPS 200 -12, - NBP Warszawa, for 5 x 65 k. VA - 175 pcs of UPS 12 -80, - Eurobank Wrocław, for 2 x 200 k. VA – 60 pcs of EPS 230 -12 and 60 pcs of EPL 210 -12, - Linxdatacenter Warszawa, for 4 x 500 k. VA - 256 pcs of EPS 230 -12, - Energa Kalisz, for 2 x 30 k. VA - 240 pcs of EPS 120 -12, - ING Bank Śląski Katowice, for 3 x 200 k. VA - 240 pcs of EPS 120 -12.
REFERENCES EUROPOWER® 2 V cells are used among others at: - Flextronics Tczew, 108 pcs of 2 V 260 Ah - 142 County Police Headquarters in Poland, 6768 pcs of 2 V 250 Ah and 48 pcs of 2 V 400 Ah - Heat and power station in Częstochowa, 212 pcs of 2 V 800 Ah - Institute of Power Engineering in Warszawa, 108 pcs of 2 V 200 Ah - DC BPT Telbank power plants, 96 pcs of 2 V 1000 Ah, 48 pcs of 2 V 600 Ah, 72 pcs of 2 V 400 Ah - Railroad Telecommunication in Gdynia, 46 pcs of 2 V 500 Ah - TK Telekom, Warszawa, 48 pcs of 2 V 1000 Ah - EXATEL SA, Warszawa, 48 pcs of 2 V 800 Ah .
Thank you We are looking forward to doing business with you!