cb647d4a0397152f893179c7ed2184ed.ppt
- Количество слайдов: 84
KX-TDA 200/100 System (Ver. 2. x) Enhanced Items Panasonic Communications Co. , Ltd. Network Business Company Edition 1. 9 24 Feb. , 2005 Confidential 1
• General System Highlights New Feature & Condition System Capacity Expansion Software Compatibility New Hardware System Connection Diagram Confidential 2
System Highlights V 1. 0 Networking(QSIG), Call Center, Vo. IP Gateway, CTI (CSTA/TAPI), T 76 xx Line Up, Wireless System V 1. 1 - Digital XDP & Double Extension Capacity by MEC - 1 Slot Vo. IP Gateway 4 ch Card (Panasonic proprietary) - New CS to DPT Port V 2. x - IP-GW 16 - IP-PT Extension - Network DSS - Sending Caller ID to SLT port - External Sensor & Relay - Hotel Feature Enhancement (7 items) - LCD for VM Operation Confidential 3
Highlight A 0 92 0 Features TD New Feature & Condition - 1 Another condition 16 ports IP-GW(CO) card IP PT Extension NDSS (Network Direct Station Selection) IP-EXT 16 Card, PT(KX-NT 136) O Caller ID to SLT (Analogue Extension) External Sensor EIO 4, OPB 3 External Relay EIO 4, OPB 3 Wake up Call Set with Voice Guidance (KX-TVA/TVM) KX-TVM Voice Message Delete when Check Out(KX-TVA/TVM) KX-TVM Check in / Check out Control 6 line_PT Telephone Charge Print Out when Check out Hotel EXT-CID Card, SLT 8 MEC Remote Wake up Call Set SMDR for External Hotel Application SMDR(Programmable) for External Hotel Application Voice Mail LCD for VM Operation (KX-TVA/TVM) KX-T 76 xx w/ LCD, KX-TVM VM Message Number Display on LCD(KX-TVA/TVM) CTI Enhancement 6 line_PT, KX-TVM O PC Phone / PC Console Improvement - DDI Name PC Phone / PC Console Improvement - Copy from Outlook (International Code) Behavior of ICD-G Key & ICM key with CTI including PC Phone / PC Console Confidential 4
Features Making Calls Another condition TRS by Dial Time out Receiving Calls TD A 0 92 0 New Feature & Condition - 2 Speed Dial Name Reference for Public Call through Private Network Incoming Call Log for Public Call through Private Network Hold / FWD / TR CLIP when Transfer Others System Speed Dial Memory Expansion MEC Personal(Station) Speed Dial Memory Expansion MEC Analogue CO line monitor 20 Pause for 2 nd Dial Code Walking Extension for Virtual Extension (For "Hot Disking" Use) Dummy Extension of PBX for CO Telephone Number SMDR 24 H Format SMDR Caller ID Modification Outgoing message (OGM) recording duration expansion Confidential 5
System Capacity Expansion Without MEC (TDA 0105), no change on system capacity made. With MEC (TDA 0105), following item’s capacities are expanded. Without MEC (TDA 0105) With MEC (TDA 0105) TDA 100 80 (108) 144 (158) TDA 200 160 (216) 288 (316) 2. Number of Extension TDA 100 64 128 (Ver. 1. 1) TDA 200 128 256 3. System Speed Dial TDA 100 32 digits, 1000 entries/System 32 digits, 1000 ent. /System (Ver. 2. x) TDA 200 4. Station Speed Dial TDA 100 (Ver. 2. x) TDA 200 1. Number of Ports (Ver. 1. 1) + 1000 ent. /Tenant x 8 32 digits, 10 entries/EXT 32 digits, 100 entries/EXT * The number of extension is consisted with all type of extension including IP-PT. Configuration of “ 1. Number of Ports” for TDA 100 Slot 1 DLC 16 16 Ext. Slot 2 DLC 16 16 Ext. Slot 3 DLC 16 16 Ext. Slot 4 LCOT 16 16 CO Slot 5 LCOT 16 16 CO 80 ports Confidential Same as left E 1 30 ch 108 ports MEC Slot 1 DLC 16 16 Ext. + 16 DXDP Slot 2 DLC 16 16 Ext. + 16 DXDP Slot 3 DLC 16 16 Ext. + 16 DXDP Slot 4 DLC 16 16 Ext. + 16 DXDP Slot 5 LCOT 16 16 CO 144 ports Same as left E 1 30 ch 158 ports 6
Software Compatibility MPR / LPR MPR 1. 0 xx & 1. 1 xx MPR 2. xxx DLC/DHLC 2. 005 Yes w/o TVM DLC/DHLC 2. 008 Yes SLC 1. 002 Yes w/o EXT-CID SLC 2. 002 Yes OPB 3 1. 002 Yes w/o EIO 4 (Relay/Sensor) OPB 3 1. 006 Yes IPGW 4 E firmware 1. 0, 1. 1 Yes w/o NDSS IPGW 4 E firmware 1. 2 Yes MPR / PC maintenance console Installation MPR 1. 0 xx & 1. 1 xx MPR 2. xxx 1. 07 Yes No 2. 0 No Yes 1. 07 + 2. 0 Yes Confidential 7
New Hardware – Option Card EIO 4 (External Input/Output) TDA 200 4 4 -port external input/output card. TDA 100 2 To be mounted on the OPB 3 card (TDA 0190). KX-TDA 0164 EXT-CID (Extension Caller ID) TDA 200 8 Sends Caller ID signals to extension ports. TDA 100 4 To be mounted on the SLC 8 card (TDA 0173). KX-TDA 0168 IP-EXT 16 (16 ch Vo. IP Extension) KX-TDA 0470 IP-GW 16 (16 ch Vo. IP Gateway) KX-TDA 0490 Upgrade SD (Upgrade to enhanced V 2. 0) KX-TDA 0920 Confidential TDA 200 8 16 -channel Vo. IP extension card. TDA 100 4 Compliant with Panasonic proprietary protocol, and ITU-T G. 729 a and G. 711 CODEC methods. TDA 200 4 16 -channel Vo. IP gateway card. TDA 100 2 Compliant with Vo. IP H. 323 V. 2 protocol, and ITU-T G. 729 a, G. 723. 1, and G. 711 CODEC methods. TDA 200 1 Optional SD Memory Card to upgrade the Hybrid IP-PBX TDA 100 1 with software version 1 or 1. 1 to version 2. x, And it adds NDSS feature and CTI enhancement, too. 8
New Hardware – Peripheral - 1 KX-NT 136 (IP-PT) Connection via IP 6 Lines 24 digits LCD /w backlit User Interface is same as T 7636. Visible Large Ring/Msg Lamp Almost of KX-T 7636 Functions is in it. PC-Phone/Console doesn’t work with. PC Maintenance Console doesn’t connect. RJ 45 RJ 9 LAN Dual color 24 Flexible Keys Benefit TDA PC Navigation Key Remote Office, Easy moving in network, Cost saving Confidential 9
New Hardware – Peripheral - 2 TVM Series (New Voice Processing System) TVM 200 TVM 50 TVP 200 TVP 50 Connection to PBX VM-Link, DPT port DPT/APT/SLT port Max. channel 12 ports (24 ch) 6 ports (6 ch) 6 ports(12 ch) 2 ports (2 ch) Max. mailbox 1024 64 1024 32 Recording media HDD Flash Recording time 128 h 8 h 32 h 6 h Programming I/F PC Soft Hyper Terminal USB, LAN, Modem RS 232 C TVM 50 All function of TVP series and New features listed below. - VM operation with LCD (T 7636, T 7633 or T 7630 is required. ) - Message notification by LCD message (6 lines LCD is required. ) TVM 200 - Wake-up call set with voice guidance for Hotel application - Voice message delete when check-out for Hotel application (6 lines LCD is required. ) - Email Notification Confidential 10
System Connection Diagram - 1 IP Connection Remote PC IP-PT PC PC Trunk (Telephone Company Lines) Analogue / BRI / PRI / T 1 / E 1 Private Router IP Network Server PC PC Batteries SLT PC APT DSS DPT DSS PC or Printer USB External Sensor/ External Relay Device T 7633/36 Doorphone & Door Opener SLT CS Wireless Phone BGM/MOH Peripheral Connection Confidential Pager/ Speaker Amplifier FAX PC ISDN Telephone DXDP T 7600 DPT PS Voice Processing System Legacy Connection 11
System Connection Diagram – 2 DLC 16 (TDA 0172) LCOT 4 (TDA 0183) DLC 8 (TDA 0171) LCOT 16 (TDA 0181) LCOT 8 (TDA 0180) CID/PAY 8 (TDA 0189) Analogue E&M DHLC 8 (TDA 0170) MSLC 16 (TDA 0175) CID 8 (TDA 0193) DID 8 (TDA 0182) PSTN E 1 IP-EXT 16 (TDA 0470) PRI 30 (TDA 0290 CE/CJ) SMDR PRI 23 (TDA 0290) CSIF 8 (TDA 0144) T 1 (TDA 0187) CTI-LINK (TDA 0410) OPB 3 (TDA 0190) DPH 4 (TDA 0161) DPH 2 (TDA 0162) IP-GW 4 E (TDA 0484) EIO 4 (TDA 0164) PSU-S/M/L ECHO 16 (TDA 0166) TDA 0108/0104/0103 Same capability of DLC SLT Wireless Phone SLT APT FAX Wireless Phone RMT (TDA 0196) PC CS PS LAN Doorphone & Door Opener PC Server PC External Sensor / External Relay Device Server PC MPR MEC (TDA 0105) IP-PT LAN MSG 4 (TDA 0191) PC Confidential SLT CSIF 4 (TDA 0143) IP-GW 16 (TDA 0490) Batteries DSS PT-IF CS BRI 4 (TDA 0284) IP-GW 4 (TDA 0480) Private Router IP Network DPT EXT-CID (TDA 0168) E 1 (TDA 0188) T 1 Voice Processing System PS SLC 8 (TDA 0173) BRI 8 (TDA 0288) ISDN PRI T 7600 DPT SLC 16 (TDA 0174) E&M 8 (TDA 0184) ISDN BRI PC T 7633/36 Pager/Speaker Amplifier Radio 12
• Function – Highlight Function - Highlight Confidential 13
16 ports IP-GW Card - 1 - model number is KX-TDA 0490. - 16 ch IPGW Card occupies a Single slot in TDA 100/200 Physical I/F single Ethernet 10/100 Base. T (auto sense) LED’s - Status, Link, Data, Online, Alarm & Busy - G 729 a/G 723. 1/G 711 - T. 38 (FAX) mode is not supported (FAX = G 711) - Configuration using Web browser (English) - 100% call compatibility with TDA 0484/3480 - Interoperability with TDA 0480 Incoming call, Outgoing call and CLIP only. - Interoperability with another manufacturers : Not guaranteed. - Power factor is 0. Confidential 14
16 ports IP-GW Card - 2 Compatibility The compatibility of the IPGW 4 (TDA 0480), IPGW 4 E (TDA 484), IPGW 16 (TDA 0490) and the TDA 30 IPGW 4 (TDA 3480) is described in the table below: Compatibility TDA 0480 TDA 0484/TDA 3480 TDA 0490 Signalling H. 323 V 2 QSIG service Proprietary H. 323 V 4 Annex M 1 511 511 Voice Codec G. 723/G. 729 a G. 711/G. 723. 1/G. 729 a FAX Protocol T. 38 G. 711 Echo canceller 16 ms 48/128 ms AGC Yes No No DTMF Tone Detection Yes Yes SNMP Yes No No Event Notice by email Yes No No DHCP No Yes (Client) NAT No No No Max networked IPGW’s Confidential 15
16 ports IP-GW Card - 3 Interoperability The interoperability of the IPGW 4 (TDA 0480), IPGW 4 E (TDA 484), IPGW 16 (TDA 0490) and the TDA 30 IPGW 4 (TDA 3480) is described in the table below: CLIP TDA 0480 connected to TDA 0480 OK TDA 3840/TDA 0484/TDA 0490 Connected to TDA 3840/TDA 0484/TDA 0490 OK TDA 3840/TDA 0484/TDA 0490 Connected to TDA 0480 OK COLP OK OK No COLR OK OK No CNIP OK OK No CNIR OK OK No CONP OK OK No CONR OK OK No CT(Avoid Tromboneing) OK OK No CF(Avoid Tromboneing) OK OK No CCBS OK OK No Making/Receiving Call OK OK OK Fax Connection OK OK No Function Confidential 16
IP PT Extension (Benefit 1) What is benefit of IP Extension Two type wirings require two types of construction, maintenance and their time. One type wiring save them. Router LAN IP-PT Unified wiring give low cost construction and maintenance. Confidential 17
IP PT Extension (Benefit 2) What is benefit of IP Extension Normal Extension IP Extension Slot: 301 Port: 02 Slot: 201 Port: 01 LAN Setting change will be required. EXT. 201 MOVE EXT. 201? EXT. 201 Just MOVE EXT. 201 IP-PT Setting change is not necessary Confidential IP-PT Easy & Quick move enable 18
IP PT Extension (Benefit 3) What is benefit of IP Extension Head Office Branch Office PBX Leased Line Head Office Branch Office PBX Router LAN IP-PT Router Private IP Network LAN IP-PT PBX is not necessary for Branch Office. All setting can be controlled by Head Office. Confidential 19
IP PT – 1 (Sample Configuration) Sample of configuration -Feature of IP PT(KX-NT 136) is basically same as KX-T 7636. Except: OHCA, USB connection, 12 CO Key connection, Digital XDP, and Walking Extension Head Office IP-PT IPEXT 16 LAN Branch Office IP-PT (DHCP Server) Primary Ethernet Port Confidential Private IP Network Secondary Ethernet Port PC 20
IP PT – 2 (Requirements) Requirements - IP-EXT 16 card is required. -DHCP (Dynamic Host Configuration Protocol) Server is not supported by IP-EXT 16 card. You need to assign IP address of IP-EXT 16 card by manual. - Cable: 100 BASE-TX Category 5 or higher - Power source: Power-over-Ethernet (Po. E) or KX-A 237 AC Adaptor is necessary Note: Following features are not supported. -OHCA, USB connection, 12 CO Key connection, Digital XDP, and Walking Extension IP-PT cannot be used for initial set-up of PBX system. Confidential 21
IP PT – 3 (Programming IP-EXT. Card) Programming Instruction Step 1 Assign IP Address for IP-EXT. card by manual Step 2 Assign IP Address for IP-PT IP Address & Subnet mask Step 3 Register IP-PT (GW Address for IP-PT) * If necessary (See page IP-PT 7) 1. Configuration IP-EXT 16 Confidential 1. Slot Property 2. System 14. IP Extension Setting 22
IP PT – 4 (Programming IP-PT) Programming Instruction Step 1 Assign IP Address for IP-EXT. card At start up 1. Power on IP-PT LCD status 2. Press “Enter” key at 1 st installation or 2. Press “Set-up” soft key from 2 nd time 2. At 1 st installation Menu Please first setup ! OK [ENTER] 1. Start up IPL Start… Step 2 Assign IP Address for IP-PT Now Loading 2. From 2 nd time Searching… Step 3 Register IP-PT 3. Select “Network” 3. Menu select Menu Network PBX VLAN Maintenance STORE EXIT CONT ENTER Setup Confidential 23
IP PT – 5 (Programming IP-PT) Programming Instruction Step 1 Assign IP Address for IP-EXT. card With DHCP Server Step 2 Assign IP Address for IP-PT 5. Select “PBX” LCD status 4. Enable Disable EXIT Confidential 6. Assign IP Address for IP-EXT 16 card 5. IP Address 0. 0 Subnet Mask 0. 0 NEXT Register IP-PT (Automatic Assignment: IP Address for Subnet mask, IP-PT Default GW) 4. DHCP: Enable DHCP Step 3 ENTER Menu Network PBX VLAN Maintenance STORE EXIT CONT ENTER 7. Store 6. PBX IP Address ? 192. 168. 0. 100 EXIT CLER ENTER 24
IP PT – 6 (Programming IP-PT) Programming Instruction Step 1 Assign IP Address for IP-EXT. card Step 2 Assign IP Address for IP-PT Step 3 Register IP-PT Without DHCP Server 4. DHCP: Disable 5. Select “IP-Address” 6. Assign IP Address for IP-PT 7. Select “Subnet mask” 8. Assign IP Address * 9. Select “Default GW” for Subnet mask *10. Assign IP Address 12. Assign IP Address 11. Select “PBX” 13. Store for Default GW for IP-EXT 16 card LCD status 4. – 8. 11. 12. DHCP Enable Disable IP Address 192. 168. 0. 101 Subnet Mask 255. 0 NEXT EXIT Confidential ENTER Menu Network PBX VLAN Maintenance STORE EXIT CONT ENTER PBX IP Address ? 192. 168. 0. 100 EXIT CLER ENTER 25
IP PT – 7 (Programming IP-PT) Programming Instruction Step 1 Assign IP Address for IP-EXT. card Step 2 Assign IP Address for IP-PT Step 3 Register IP-PT Without DHCP Server Head Office Router Private Router Branch Office IP Network Gateway: 192. 169. 0. 1 IPEXT 16 LAN IP-PT Gateway: 10. 75. 0. 1 DHCP Enable Disable Default Gateway 192. 168. 0. 1 PREV EXIT IP-PT ENTER PC Confidential 26
IP PT – 8 (Register IP-PT to PBX) Programming Instruction Step 1 Assign IP Address for IP-EXT. card Step 2 Assign IP Address for IP-PT Step 3 Register IP-PT Select: ON Registration: Start Registration UNREGISTERED TO SERVER OK[ENTER] LCD of IP-PT is changed to normal 30 SEP. 11: 09 AM FRI PROG INFO RING MENU 1. Configuration Confidential 15. IP-Extension Port Confirm: OK 27
IP PT – 9 Virtual LAN VLAN Name : Sales ID : 1 Port on VLAN: 1 -4 Tagged VLAN: Null PHY. Port 1 VLAN No. 1 2 1 3 1 4 1 5 2 6 2 VLAN(L 2 Switch) Local Office Remote Office Necessary Information IP-PT EXT. 101 IP-PT EXT. 102 IP-PT EXT. 103 IP-PT EXT. 104 IP-PT IP Address 192. 168. 0. 101 Subnet Mask Address Default Gateway Address Card IP Address VLAN ID 192. 168. 0. 102 10. 75. 0. 103 10. 75. 0. 104 255. 0 192. 168. 0. 1 10. 75. 0. 1 192. 168. 0. 100 1 VLAN ID is necessary for IP-PT and VLAN(L 2 Switch) Confidential 28
IP PT – 10 Virtual LAN L 2 switch configuration Router PHY. Port 1 VLAN No. 1 VLAN Name : Sales ID : 1 Port on VLAN: 1 -4 Tagged VLAN: Null 3 1 4 1 5 2 6 2 L 2 Switch Gateway: 192. 169. 0. 1 Head Office Private IP Network VLAN ID = 1 IPEXT 16 2 1 Gateway: 10. 75. 0. 1 Branch Office VLAN ID = 1 LAN VLAN ID = 1 IP-PT VLAN ID = 1 LCD status Menu Network PBX VLAN Maintenance STORE EXIT CONT ENTER Confidential VLAN ID = 1 VLAN Enable Disable Primary port Secondary port (TO PC) EXIT ENTER Primary port VLAN ID VLAN Priority 1 7 29
NDSS (Network Direct Station Selection) TDA 0920 is required. - NDSS is a DSS key referring to an extension of other PBX - It works with both of the open numbering and the closed numbering. - It’s used for monitoring extension status and making or transferring calls. - Only one TDA can be a Monitor PBX - Maximum 32 extensions in the network can be monitored. Idle - Any extension of Monitor TDA can have NDSS. (Network Operator) - Both of Monitor PBX and Monitored PBX require KX-TDA 0920 302 303 304 Off = Idle Red On = Busy, DND (trunk) Push = To call to extension Network Operator Benefit Confidential Monitor PBX KX-TDA 0920 Mandatory QSIG, Vo. IP Network Monitored PBX KX-TDA 0920 Mandatory 302 Busy 303 304 Centralized Operator 30
NDSS – 2 TDA 0920 is required. Network PBX ID Each TDA 100/200 V 2. x has Network PBX ID. ID=1 Monitor PBX ID=2 -8 Monitored PBX ID=0 (default) * Refer PRG 1 Normal PBX ID=4 Monitored Ext QSIG, Vo. IP Network ID: none Other PBX ID=3 Monitored Ext ID=2 Before V 2. 0, TDA 30, TD 500 Monitored Ext ID=0 ID: 1 Monitor PBX ID=0 Each ID must be unique in the network. ID=0 Only one in the network. ID=0 V 2. x or later ID=1 ID=0 Network Operator ID: 2 -8 Monitored PBX V 2. x or later ID: 0 (default) Normal PBX It’s neither a monitor PBX nor a Monitored PBX. Some PBXs transmit status information of Monitored Ext. V 2. x or later Confidential 31
NDSS – 3 Status Information Routing Case : Vo. IP Q-SIG Transmitting route for Status Information data 402 Busy must be constructed. Case : ISDN (PRI, BRI) Q-SIG ON * Refer PRG 2 OFF Network Data Transfer Yes (ON) : Send No (OFF) : Receive * Q-SIG port base setting * Refer PRG 5 * Refer PRG 3 NDSS data Transfer Vo. IP ISDN : Enable 402 Busy 102 OFF ID=1 101 Network Operators Confidential ON ISDN Q-SIG 302 Busy ID=0 OFF ON OFF ID=0 ISDN Q-SIG 103 ISDN Q-SIG ID=0 ON ISDN Q-SIG ON IPGW at slot 1 IPGW at slot 3 IPGW at slot 6 TDA 0920 is required. ID=3 Status Info. IP Routing Table Network Operator = 102 IPGW Card Slot to send out = slot 3 IP Netwo rk Vo. IP Q -SIG 402 Idle ID=3 Busy Monitored Ext OFF ID=0 ON ISDN Q-SIG ID=2 302 Idle Busy Monitored Ext 32
NDSS – 4 TDA 0920 is required. Network Monitor Extensions Table 102 * Refer PRG 4 Max. 32 Ext. Monitor Extensions Table No. Ext. Name for reference Network PBX ID 302 2 001 002 402 3 003 QSIG, Vo. IP Network ID=1 ID=3 Monitored Ext 101 032 402 ID=2 Network Operators * Only for a monitor PBX 302 Monitored Ext Starting monitoring & Stopping monitoring All NDSS start monitoring. To start monitoring To stop monitoring * Any extension can do. NDSS * 7 8 4 Network Ext. No. or NDSS # C. Tone * Only a manager extension can do. Confidential 33
NDSS – 5 TDA 0920 is required. Conditions -TDA 0920 must be in both of monitor PBX and monitored PBX. - The firmware (not LPR) of IP-GW 4 E(TDA 0484) must be Version 1. 2 or later. - Network PBX ID: 1 -8 must be unique in the network. - It’s possible to stop monitoring at monitored PBX by PC Maintenance Console. - NDSS does not work on PC-Phone / PC-Console. - You can not back up all of NDSS configuration into DSYS. ( * You need to check and re-configure some part of NDSS after initialize reset, even you have DSYS as backup. ) Updating Firmware of IP-GW 4 E (1) Connect a browser to IP-GW 4 E. ( Updating is done through a browser. It’s not from PC Maintenance Console. ) (2) Login to IP-GW 4 E with the name: Installer, PW: Installer. (3) Change the status of the card from “RUN” to “STOP”. (4) Now, you can upload a firmware and update the card with the procedure in the manual (3. 3 Data Management). Confidential 34
NDSS – 6 TDA 0920 is required. Programming Instruction - 1 Only when ID = 1 Network PBX ID Assignment PRG 2 NDSS data transfer PRG 3 Only when ID = 2 - 8 PRG 1 Status Info. Routing Table Vo. IP ISDN Vo. IP * The PBX(ID=0) can’t perform this direction. How many time NDSS data can be transferred Frequency of NDSS data from IPGW or PRI card Any extension number which is reachable from this monitor PBX A slot number of IPGW card which the data is sent from Up to 32 PRG 4 Confidential Network Monitor Extensions Table 35
NDSS – 7 TDA 0920 is required. Programming Instruction - 2 Data transmitting direction over Q-SIG Case : ISDN (PRI, BRI) Q-SIG ON PRG 5 Confidential OFF Network Data Transfer Yes (ON) : Send No (OFF) : Receive * Q-SIG port base setting 36
Caller ID to SLT - 1 Caller ID from SLC port to Normal Telephone, Cordless Telephone, FAX machine, etc. FSK (ETSI and Bellcore) signaling only 16 digits maximum Adding Trunk Access Number for calling back Purpose (Programmable) TDA 0173 (SLC 8) and TDA 0168 (EXT-CID) are required. For Calling back (Programmable) PSTN (0, 9) + 12345678 Caller ID : 12345678 FSK, DTMF, others Max. 16 digits EXT-CID SLC 8 Only FSK 302 Benefit Confidential (0, 9) 12345678 302 Recognizing caller, easy calling back 37
Caller ID to SLT - 2 Action in Unscreened transfer operation CID: 12345678 302 Receiving a call 12345678 Answer and transfer TR 302 SLT stops ringing and rings again On Hook 12345678 Condition - CID is between 1 st bell and 2 nd bell - Incoming Call Log Information is not shown on the SLT. - TDA 0168(EXT-CID) must be installed on TDA 0173(SLC 8). - LPR software of TDA 0173 (SLC 8) must be 2. 002 or later. - One EXT-CID supports 8 ports. (All ports of SLC 8 which has EXT-CID on it can send out CID. ) - EXT-CID can be installed onto all off SLC 8 s in a TDA system. Confidential 38
Caller ID to SLT – 3 Programming items - 1 Adjusting interval: 0 -15 Enable sending CID to Ext. : Enable/Disable Adding Trunk Access Number: Enable/Disable Confidential 39
Caller ID to SLT - 4 Programming items - 2 CID Modification table - modified CID will be sent to SLT port SLC 8 Property Check if EXT-CID is installed Confidential 40
Caller ID to SLT – 5 Priority of items displayed when TDA is receiving FSK CID may bring information such as private, out of area or long distance. If TDA received high Result “private” or “out of area” is displayed. “long distance” is displayed. Another items priority “private” or “out of area” Caller ID and Name is displayed. low Confidential 41
External Sensor - 1 If a device connected to the external sensor becomes active, there are 3 outcomes: (1)Sensor call will be generated to the pre-programmed extension (2)Generates SMDR Printout (3)Generates 3 rd Party CTI command The sensor call destination can be a PT, SLT, PS, or ISDN extension but not an ICD-Group. - If a sensor call arrives at an extension Display : pre-assigned name of sensor port [5. 5] Ring : Distinctive ringer pattern can be assigned (triple, or special double ring, so on) [2. 8. 3] - Special Tone(Dial Tone 3) will be sent to answering extension. - If nobody answer sensor call, sensor call stops with pre-programmed time [2. 4. 3]. Confidential 42
External Sensor - 2 Timings The External Sensor has some timing parameters that can be set using the maintenance console [1. ] and clicking on the OPB 3 card. Input Signal Decision Time = This is the time delay before Extension begins to Ring. Input Signal Detection Reopening Time = This is the time it takes the sensor to reset hence the time it will take to respond to the next input. Confidential 43
External Sensor - 3 Connection Diagram Power to the external sensor is provided from the EI 04 card and must be grounded through the EI 04 card as indicated in the diagram below. A pair of “sensor” and “common” lines are connected to the EI 04 card for each external sensor. The TDA detects inputs from the sensor when the signal is under 100 Ohms. Confidential 44
External Relay Extensions can activate external relay for controlling external devices(On/Off) by feature code. There is a COS that has to be programmed to enable this feature. It is possible to activate the relay for pre-programmed time [5. 4]. The relay is the relay normally open. And has a maximum switching voltage of : 24 VDC(1 A) 30 VAC(1 A) Confidential 45
• Function – Hotel Function - Hotel Confidential 46
Hotel - 1 - Wake up Call Set with Voice Guidance (KX-TVA/TVM) - Voice Message Delete at Check Out, Automatically(KX-TVA/TVM) 6 Line LCD PT for Hotel Operator - Check in / Check out Control - Telephone Charge Print Out when Check out - Remote Wake up Call Set “Wake up call is set at 07: 30. ” KX-TDA 200 or TDA 100 - SMDR for External Hotel Application - Programmable SMDR for External Hotel Application Confidential KX-T 7636 KX-TVA 200 or TVM 200 47
Hotel - 2 Operation Assignment Check in Hotel Operator EXT. Check in button Check in + Room No. (EXT. No. ) Remote Wake up Call set Dial *76*1 + Room No. + Time Check out + Room No. (EXT. No. ) + Print / YES Confidential Automatic voice message delete *Check out button Automatic telephone charge print out *Check in / Check out *Telephone / Minibar / Others *Timed reminder Start / Answer / No response *Programmed message *Header / Footer *Charge: Margin/Tax *Telephone margin *TAX rate: telephone /minibar/others *Select print item 48
Hotel - 3 (Check In) - Check in / Check out Control 6 Line LCD PT for Hotel Operator Check-in: On hook status Check-in button Check-out: On hook status Check-out button Confidential Enter Dial EXT. No. or DSS Enter 49
Hotel - 4 (Wake up Call / Check Out) -Remote Wake up Call Set 1: Set or EXT. No. or DSS 0: Cancel 0: Once Hour: Minute (+ 0: AM 1: PM by 12 H) or 1: Dairy Off hook status Dial * 7 6 * - Telephone Charge Print Out when Check out Check-out: On hook status Check-out button Enter “Minibar” and “Others” Enter PRINT Dial EXT. No. or DSS NEXT Enter YES (Soft Key) LCD status Room: 103 Enter Room Number EXIT Confidential ENTER Telephone: 00000. 00 Minibar : 00000. 00 Others : 00000. 00 EXIT NEXT PRINT Room: 103 Confirm check out ? NO YES 50
Hotel - 5 (SMDR Setting) - SMDR for External Hotel Application Check in/out Timed Reminder Start/Answer/No Response -Programmable SMDR for External Hotel Application Printing Message (on SMDR) can be assigned. Dial *761 Confidential Printing Message No. # 51
Hotel - 6 (Billing Sheet) Sample of Call Billing Sheet Confidential 52
Hotel - 7 (Rate Calculation) Margin/Tax Rate Assignment [Calculation Method] Pay tone: Analog trunk + pay tone card Meter Pulse: E 1 line [Meter indication received from telephone company] x [Call Charge Rate] [1 - Tax Rate] x [1 - Margin Rate] Advice of Charge: ISDN [Charge received from telephone company] [1 - Tax Rate] x [1 - Margin Rate] Confidential 53
• Function – Voice Mail Confidential 54
LCD for VM Operation - 1 (Receive a Message) The screen shots show easy it is to Receive a Voice mail message with the new KX-TVM series. Main Menu Receive Msg. Deliver Msg. Check Distribution A. A. Status EXIT Condition -PT must be T 76 xx with LCD. - Max. 5 Language’s 3 messages ROBINE 2 AUG 24 03: 47 PM! MBX 203 AUG 24 11: 04 AM! 3275307 AUG 24 09: 23 AM EXIT Confidential ERASE PLAY ROBINE SCHNEIDER MBX 120 AUG 24 03: 47 PM NEW 00: 03: 12 ****-----SHIFT EXIT ERASE STOP 55
LCD for VM Operation - 2 (A. A Status) Main Menu Receive Msg. Deliver Msg. Check Distribution A. A. Status EXIT A. A. Status Call Transfer Covering Extn. Mbx. Retention Mode Incomplete Handling EXIT Confidential The screen shots show easy it is to change the automated attendant settings with the new KX-TVM series. Call Transfer Status Disable Blocking Enable Screening Disable Int. Paging Disable Beeper EXIT DALL 56
Voice Mail Message Number display on LCD The number of new messages can be indicated on the LCD of PT. This feature is supported on TVM series voice mail. Condition - PT with 6 line LCD 26 JUL. 10: 20 AM MON Incoming Call : 001 Voice Message : 002 PROG Confidential INFO RING MENU 57
• Function – CTI Function - CTI Confidential 58
CTI Enhancement TDA 0920 is required. New Functions Multi. PBX Loading Function 2 PBXs are controlled by TAPI. Supporting New Hardware * This does not mean External Sensor, IP-PT Controlling PT that PMS controls two PBXs. IP-PT PS MIC YES YES MWL YES FCO key YES SP On/Off YES SP Volume YES Ring On/Off YES YES LCD Display contents Another enhancement PT YES YES Controlling Ring Pattern for redirected call Setting Extension Absent Message Condition - KX-TDA 0920 is mandatory. - Windows 2000(Pro, Server) or Windows XP(Pro) - TSP Built 2. 0. 0. 27 or later - USB ports or LAN interface on PC Confidential 59
PC Phone / PC Console Improvement New Features New Feature Enhancement for “External Sensor” New Feature Enhancement for display the DDI Name from PBX when alerting DDI(DID) name of PBX can be displayed. DDI(DID) name of PC has priority. Improvements Import function from Outlook Phone Book(the method for International code) For example, "+81 -92 -477 -1234" will be 0081924771234 or 924771234 by programming. Screen sentences were revised to correct sentences (except English) When “Call Pickup by DSS ICD Group Call” is disabled by programming, the operator can not answer the call from Incoming Group screen. Before the operator can answer the call from Incoming Group screen. New when it saved without inputting to Text. Memo, Incoming/Outgoing record (Call Log) is not left in Call Log. Before Incoming/Outgoing record (Call Log) is left in Call Log. New Under using Italian language, Before the operator cannot attach a photo into “Pop-up” except BMP. the operator can attach a photo into “Pop-up” with other than BMP format, too. New Confidential 60
• Function - Making Calls Function – Making Calls Confidential 61
TRS by Dial Timeout - TRS by Dial Time out (Inter-digit timer is working in checking TRS. ) Example 1: Operation in U. S. A. RESTRICT 0: Call PTT Operator in North America NO RESTRICTION 00: Credit Call Keep (default) Disconnect Activate this feature! FWD to 9 Confidential l dia s CO-CO call No DTMF-R in trunk cards DTMF dialing can go thru. (No check) Disconnect FWD to 9 Restriction table 99 restrict s l dia PSTN Keep PSTN Example 2: Preventing escaping from TRS CO-CO call No DTMF-R in trunk cards DTMF dialing can go thru. (No check) But TDA disconnects by the timer. 62
• Function - Receiving Calls Function – Receiving Calls Confidential 63
Speed Dial Name Reference through Network 1234567 Panasonic 1 234567 Telecom Line Private Network If Caller ID is matched to the number in System/Personal Speed Dial, the correspond name can be displayed on LCD. It is effective through Network, too. 6. Feature Panasonic 9+1234567 1. Speed Dialing & Caller ID 1. Main Table Confidential 64
Incoming Call Log for Public Call through Private Network TDA distinguishes incoming calls from the private network between private call and public call. CID: 06 -4444 -5555 Public Call CID: 06 -4444 -5555 CID: 03 -1234 -5678 10 digits > 9 Public Call 6 digits =< 9 Private Call Type=“Private” CID: 03 -1234 -5678 CID: 952 -101 Type=“Private” Public Network Ext. 101 PBX code 952 Private Network Threshold Value =9 Incoming Call Logging Priority condition Call Type Info. Digits Comparison Result From other PBX With threshold Public Don’t Care Public Private Over Public Private Under or equal Private * TDA V 2. x can send correct call type. TDA V 1. 0, V 1. 1 send “Private Call” as call type. Threshold value: 0 -15 (default: 9) Confidential 65
• Function – Hold/Forward/Transfer Confidential 66
CLIP when Transfer CLIP to be sent to CO when transferring (to CO) has following choices. - send CID which is sent in usual of the extension’s making a call - send CID of held CO party * This configuration does not apply for Call Forwarding. CLIP in forwarding is received CID. Disable (default): send CID of EXT Enable : send CID of Held CO Party Confidential 67
• Function – Others Function - Others Confidential 68
Others - 1 - Memory Expansion System Speed Dial TDA 100 32 digits, TDA 200 1000 entries/System MEC 32 digits, 1000 ent. /System + 1000 ent. /Tenant x 8 Each Tenant has a choice. - to use a list for system - to use a list for tenant Station Speed Dial TDA 100 32 digits, (Personal Speed Dial) TDA 200 10 entries/EXT (01 -09) MEC 32 digits, 100 entries/EXT (00 -99) Original 10 entries aren’t copied to first 10 entries in 100 entries. Confidential 69
Others - 2 - Analog CO Line Monitor Detection of physical line disconnection If CO line is disconnected physically, the CO port become Out of Service Automatically. Except AL/NE model LCOT card by difference of hardware - 20 Pauses for 2 nd Dial Code V 1. 1 = Max. 4 Pauses V 2. x = Max. 20 Pauses Confidential 70
Others - 3 - Walking Extension for Virtual Extension V 1. 0= SLC 16 without phone V 1. 1= DLC 16 temporary use only - Dummy Extension of PBX for CO Tel. No. PBX recognize CO Tel. No. as EXT. No. You can use mobile phone like as extension. TDA 100/200: Max 128 PS or Mobile phone TDA 30: Max 28 PS or Mobile phone Confidential 71
Others - 4 - SMDR Enhancement Time stump in 24 h format - 24 H - 12 H Default of NE Default of others Caller ID Modification - Before Modification Default of US, Canada - After Modification Default of others Example 1: Default for US/Canada is "Before Modification". Default for other is "After Modification". For example, call from 0312345678 through ISDN CO will be print as 312345678 by "Before Modification" mode. 0312345678 by "After Modification" mode. Example 2: 441633653666(Call from UK) or 44163365366(Call in US) by "Before Modification" mode 010441633653666(Call from UK) or 144163365366(Call in US) Confidential by "After Modification" mode 72
Others - 5 - Outgoing message (OGM) recording duration expansion V 1. 1 or before V 2. x Total 8 minutes Up to 64 messages One Max. minute for each message Confidential Eight Max. minutes for each message 73
• To Start TDA 100/200 V 2. x Confidential 74
PC Maintenance Console Compatibility Initial Screen Automatically V 1. 1 is connected. V 2. x is connected. Aut om atic ally V 1. 0 is con nec te d. V 2. 0 Confidential Two versions are installed into a PC. V 1. 07 75
PC Maintenance Console Installation - 1 PCC provides two installers. pcprogv 2000 R 5. exe * or later (V 2. 0) pcprogv 107 c. R 3. exeor later (V 1. 07) * Only for TDA V 2. x For TDA V 1. 1 & V 1. 0 The Installation order is important. 1 st install Case 1: 2 nd install V 1. 07 + V 2. 0 Installation without uninstalling 1 st install. Result Possible programming TDA TDA V 1. 0 V 1. 1 V 2. x Yes Yes OK ! Yes No No good ! Case 2: V 2. 0 + V 1. 07 Case 3: V 2. 0 None No No Yes Case 4: V 1. 07 None Yes No You need UNINSTALL V 1. 07 and V 2. 0 and install again in correct order. * You can uninstall both of V 1. 07 and V 2. 0 at once in normal uninstall operation. Confidential 76
PC Maintenance Console Installation – 2 Area Selection Difference V 1. 07 “Please enter your country code …” Confidential V 2. 0 “Please select suffix code. ” 77
Data Conversion 1. Back up DSYS (V 1. 0 or V 1. 1) to PC 1 -1 “Tool” => “SD Memory Backup” 1 -2 “Utility” => “File Transfer PBX (SD Card) to PC” 2. Update DSYS to V 2. x by PC Maintenance Console V 2. 0 2 -1 Open DSYS (V 1. 1 or V 1. 0) from PC Maintenance Console V 2. 0. 2 -2 Following dialog appears. Going back to initial screen. No conversion, opening DSYS as it is. 3. Conversion Complete. DSYS of V 2. x is saved at local PC Caution : Converting from V 1. 0 requires PC Maintenance Console V 1. 07, too. Confidential 78
Upgrade PBX 1. Prepare following files - PMPR 2. x, DLNG 0 2. x, DLNG 1 2. x , DINI 2. x - DSYS 2. x --- Converted DSYS or New DSYS created by PC Maintenance Console - MSG Backup File -- DISA/OGM backed up Messages. (see next page. ) Messages in MSG 4 card will disappear when TDA is upgraded to V 2. x. 2. Download above files except MGS Backup File to PBX 3. Reset PBX by command - V 1. 0054 or later --- Please select PMPR_SUB, DSYS_SUB, then reset - Before V 1. 0054 --- Please reset without any care. Select 4. Connect PC-Soft again and download other files as the dialog box saying. 5. If PC-Soft require reset, reset PBX again, then download MSG Backup File. Confidential (End) 79
Save/Load OGM/DISA Messages Change status of OPB 3 to OUS. Then do following procedures. o Save t Select MSG 4 position File Save Screen PC Save with your favorite file name. Lo Save complete! o. P t ad BX Select MSG 4 position File Select Screen Select file and Load to PBX. Load complete! Confidential 80
Enhancement by Upgrade SD card - 1 1. Some features are enabled by Upgrade SD card (KX-TDA 0920). + KX-TDA 0920 = - TDA V 1. 0 Upgrade SD - TDA V 1. 1 - TDA V 2. 0 (Normal) What is an upgrade SD ? TDA V 2. 0 Enhanced Normal SD File: + DKEY-SD = KX-TDA 0920 The information in DKEY-SD is different for each SD card. 2. Enhancement procedure From V 1. 0 or V 1. 1 V 2. x (working) V 2. x (brand new) Step 1 Make backup of TDA 0920 into local PC Yes Yes Step 2 Backup current DSYS to PC Yes Step 3 Convert DSYS to V 2. 0 Yes Step 4 Change SD to TDA 0920, then execute initialize reset Yes Step 5 Send User’s DSYS to TDA Yes Yes 5 -1 “Utility” => “File Transfer PC to PBX (SD Card)”, DSYS will be saved as DSYS_SUB. 5 -2 Restart from command with following choices. DSYS: Use Replace File TDA V 2. x Enhanced begins to work. Confidential PMPR: Keep Present File 81
Enhancement by Upgrade SD card - 2 3. Data Reset After Upgrade Log - Incoming Call Log Group - Outgoing Call Log (including Last Number Redial) Status - Message Waiting (All extensions are set to Ready by default. ) Others - ICD Group monitor log for supervisor System (All extensions are set to Login by default. ) - ICD Group Ready/Not Ready status - SMDR - Advice of Charge (AOC) / Pay Tone - ICD Group login status - Extension Lock/Remote Extension Lock - Extension PIN Lock/Extension PIN Lock counter - PBX date and time - Verified Code PIN Lock/Verified Code PIN Lock counter - Timed Reminder - Password Lock counter for Remote System Programming - LPR Timed Update time - PBX Error Log - Daily test start time PT/Ext - PT handset/headset volume Status - PT SP-PHONE volume - PT ring volume And - PT display contrast PS registration information will be cleared, too. - Live Call Screening (LCS) On/Off - Hands-free Answerback status - Absent Message status of extensions (Absent Message data itself is no cleared. ) - Fwd/DND status (FWD destinations are not cleared. ) Confidential 82
Enhancement by Upgrade SD card - 3 4. How to go back to normal TDA Prepare SD card of previous version. (Normal V 2. x, V 1. 1 or V 1. 0) Step 1 Set the slide switch position to “Lock”, then insert to TDA. * TDA must be turned off, at first. Step 2 Execute initialize reset of TDA Step 3 Set the slide switch position to “Un-Lock”, then insert to TDA. * TDA must be turned off, at first. Step 4 Execute normal reset of TDA (It’s no need to send DSYS to TDA. ) TDA begins working with previous version. Confidential 83
• Thank you very much ! Confidential 84