July 2004 ABB© PTMV - 1 Brian Johnson Medium Voltage Outdoor Apparatus Portfolio ABB July 2004 ABB© PTMV - 1 Brian Johnson Medium Voltage Outdoor Apparatus Portfolio ABB

Typical Overhead Distribution System 1 PH Switch - 1 Ph Manual OR Fuse OR Typical Overhead Distribution System 1 PH Switch - 1 Ph Manual OR Fuse OR Cutout Switch - 1 Ph Manual Cutout OR 1 Ph Sectionalizer Capacitor Switch 3 PH Line Recloser 3 Ph Sectionalizer Breaker / Recloser Reconfiguration Switch - Manual - Automated ABB© PTMV - 2 Switch - Manual - Automated 3 PH ABB

PTMV Outdoor Apparatus Portfolio n Outdoor Circuit Breakers n Reclosers n Automated Sectionalizers n PTMV Outdoor Apparatus Portfolio n Outdoor Circuit Breakers n Reclosers n Automated Sectionalizers n Sealed Switches n Air Switches n Fused Cutouts n Not in portfolio, today: ABB© PTMV - 3 n Voltage Regulators n Insulators, Cables, Hardware ABB

Outdoor Circuit Breakers Dead Tank Type R-Mag 15 -27 k. V ANSI & IEC Outdoor Circuit Breakers Dead Tank Type R-Mag 15 -27 k. V ANSI & IEC Type V 38 k. V ANSI ABB© PTMV - 4 Live Tank Type SDB 12 12 k. V IEC Type OHB 24 -36 k. V IEC ABB

Type R Dead Tank Circuit Breaker n Vacuum Interruption n Spring Operated Mechanism n Type R Dead Tank Circuit Breaker n Vacuum Interruption n Spring Operated Mechanism n ANSI C 37. 06 – 1997 n Dead tank design reduces cost of CTs and installation n Manufactured ABB, USA ABB© PTMV - 5 Voltage Rated Continuous Current Interrupting Current 15 – 27 k. V 600 – 3, 000 A 12 – 25 k. A ABB

Type R-Magnetic Dead Tank Circuit Breaker n Vacuum Interruption n Magnetic Actuator Mechanism reduces Type R-Magnetic Dead Tank Circuit Breaker n Vacuum Interruption n Magnetic Actuator Mechanism reduces maintenance costs and concerns n ANSI C 37. 06 – 1997 & IEC 56 n Manufactured ABB, USA ABB© PTMV - 6 Voltage Rated Continuous Current Interrupting Current 15 – 27 k. V 600 – 3, 000 A 12 – 25 k. A ABB

Type V Dead Tank Circuit Breaker n Vacuum Interruption n Spring Operated Mechanism n Type V Dead Tank Circuit Breaker n Vacuum Interruption n Spring Operated Mechanism n 150 or 200 k. V BIL n High capacitor switching ratings to use to protect and switch substation capacitor banks n Redundant vacuum bottle n ANSI C 37. 06 – 1997 n Manufactured ABB, USA ABB© PTMV - 7 Voltage Rated Continuous Current Interrupting Current 38 k. V 1, 200 – 2, 000 A 25 – 40 k. A ABB

Type SDB 12 Live Tank Circuit Breaker n Vacuum Interruption n Spring Operated Mechanism Type SDB 12 Live Tank Circuit Breaker n Vacuum Interruption n Spring Operated Mechanism or Magnetic Actuator Drive n IEC n Manufactured ABB, India Interrupting Current 12 k. V ABB© PTMV - 8 Voltage Rated Continuous Current 630 – 1, 600 A 18. 4 – 26. 3 k. A ABB

Type OHB Live Tank Circuit Breaker n SF 6 Interruption n Spring Operated Mechanism Type OHB Live Tank Circuit Breaker n SF 6 Interruption n Spring Operated Mechanism n IEC n Manufactured ABB, India Interrupting Current 24 – 36 k. V ABB© PTMV - 9 Voltage Rated Continuous Current 2, 500 A 31. 5 k. A ABB

Automated Reclosers and Sectionalizers OVR – 3 Phase Recloser 15 -38 k. V ANSI Automated Reclosers and Sectionalizers OVR – 3 Phase Recloser 15 -38 k. V ANSI & IEC OVS – 3 Phase Sectionalizer 15 -38 k. V ANSI & IEC Autolink – 1 Phase Sectionalizer ABB© PTMV - 10 12 -38 k. V IEC OVR – 1 Phase Recloser 15 -38 k. V ANSI & IEC ABB

OVR Three Phase Automated Recloser Embedded Vacuum Interrupters in Solid Dielectric (no oil, nor OVR Three Phase Automated Recloser Embedded Vacuum Interrupters in Solid Dielectric (no oil, nor SF 6 to maintain) n Magnetic Actuators n Pole or Substation Mounting n Programmable PCD Control to automate system protection – loop schemes, automatic alternate settings n ANSI C 37. 60+90 – 1997 n ABB© PTMV - 11 n Manufactured ABB, USA Voltage Rated Continuous Current Interrupting Current 15 – 38 k. V 560 – 800 A 12 – 16 k. A ABB

OVR Single Phase Automated Recloser n Ratings: n 15 – 38 k. V n OVR Single Phase Automated Recloser n Ratings: n 15 – 38 k. V n 630 / 800 Amp n Up to 170 k. V BIL n 12. 5 k. A Compact, lightweight n HCEP Insulation Material n Superior life – rated for 10, 000 operations n 2 nd Generation Magnetic Actuators n ABB© PTMV - 12 n Environmentally friendly – no oil or gas n ANSI C 37. 60+90 – 1997 n Manufactured ABB, USA ABB

OVS Three Phase Automated Sectionalizer n n Simple Sectionalizing Control n ANSI & IEC OVS Three Phase Automated Sectionalizer n n Simple Sectionalizing Control n ANSI & IEC n ABB© PTMV - 13 Pole or Substation Mounting n 15 – 38 k. V Magnetic Actuators n Voltage Embedded Vacuum Interrupters in Solid Dielectric Manufactured ABB, USA Short Time Rated Continuous Withstand Current 3 Sec. Sym 630 A 16 – 20 k. A ABB

Autolink Single Phase Sectionalizer n Single Phase Automatic Sectionalizer n Specialty device to reduce Autolink Single Phase Sectionalizer n Single Phase Automatic Sectionalizer n Specialty device to reduce nuisance tripping problems n Magnetic Actuation to eliminate fuse replacement costs n IEC n Manufactured ABB T&D Ltd, Australia ABB© PTMV - 14 Voltage Rated Continuous Current Interrupting Current Actuating Current 12 – 36 k. V 250 A 6 k. A 5 – 224 A ABB

Sealed Contact, Loadbreak Switches OVS Sectos NXBD ABB© PTMV - 15 15 -38 k. Sealed Contact, Loadbreak Switches OVS Sectos NXBD ABB© PTMV - 15 15 -38 k. V ANSI & IEC 12 -24 k. V IEC Sectos NXA Sectos NXB 38 k. V ANSI & IEC 12 -24 k. V IEC ABB

OVS Automated Switch ISD or PCD Control for simple applications or sophisticated automation schemes OVS Automated Switch ISD or PCD Control for simple applications or sophisticated automation schemes n ANSI & IEC n Manufactured ABB Inc. , USA n Development project to add visible break n 10, 000 loadbreak operations n 15 – 38 k. V Magnetic Actuators n Voltage Embedded Vacuum Interrupters in Solid Dielectric n ABB© PTMV - 16 n SCADA Ready – integrated current sensing, voltage sensing on frame, control cabinet space and power for customer communications Short Time Rated Continuous Withstand Current 3 Sec. Sym 630 A 16 – 20 k. A ABB

Sectos NXA Switch Disconnector n Two-position Load Break-Fault Make Switch Disconnector n Single or Sectos NXA Switch Disconnector n Two-position Load Break-Fault Make Switch Disconnector n Single or Double Spring Mechanism n Manual (Hook stick) or Integrated Motor Operated n Shipped complete, Simple to install n SF 6 insulation n IEC (General Purpose Type) & ANSI n Manufactured ABB, China ABB© PTMV - 17 Voltage Rated Continuous Current Short Time Withstand Current 3 Sec. Sym 36 k. V (38 k. V ANSI) 630 A 12. 5 k. A ABB

Sectos NXB Switch Disconnector Two or Three-position Load Break-Fault Make Switch Disconnector n Single Sectos NXB Switch Disconnector Two or Three-position Load Break-Fault Make Switch Disconnector n Single or Double Spring Mechanism n Manual (Hook stick) or Integrated Motor Operated n Shipped complete, Simple to install n Available in single phase for special applications n SF 6 insulation n IEC (General Purpose Type) n ABB© PTMV - 18 n Manufactured ABB, China Voltage Rated Continuous Current Short Time Withstand Current 3 Sec. Sym 12 – 24 k. V 630 A 20 k. A ABB

Sectos NXBD Switch Disconnector n Two Switches in Same Housing n Two Switched Ways Sectos NXBD Switch Disconnector n Two Switches in Same Housing n Two Switched Ways and One Tapped Way Two or Three-Position Load Break-Fault Make Switches Disconnector n Single or Double Spring Mechanism n Manual Operation by Hook Stick n Shipped complete, Simple to install n SF 6 Insulation n IEC (General Purpose Type) n ABB© PTMV - 19 n Manufactured ABB, China Voltage Rated Continuous Current Short Time Withstand Current 3 Sec. Sym 12 – 24 k. V 630 A 20 k. A ABB

Three Phase Air Switch Disconnects Series ‘U’ NPS 12 -36 k. V IEC ABB© Three Phase Air Switch Disconnects Series ‘U’ NPS 12 -36 k. V IEC ABB© PTMV - 20 Series ‘R’ 12 -36 k. V IEC ABB

NPS Switch Disconnector n Vertical and Horizontal Break n Vertical and Horizontal Pole. Mounted NPS Switch Disconnector n Vertical and Horizontal Break n Vertical and Horizontal Pole. Mounted n Optional Load Break and Load Make n Control Units (DTU) available n IEC (Limited Purpose Type) n Manufactured ABB, Finland n Easy to localize, if desired ABB© PTMV - 21 Voltage Rated Continuous Current Short Time Withstand Current 3 Sec. Sym 12 – 24 k. V 630 A Up to 16 k. A ABB

Series ‘R’ Disconnect Switch n Vertical Break n Horizontal & Vertical Pole Mounted n Series ‘R’ Disconnect Switch n Vertical Break n Horizontal & Vertical Pole Mounted n Optional Load Break n IEC n Manufactured ABB, Australia ABB© PTMV - 22 Voltage Rated Continuous Current Short Time Withstand Current 3 Sec. Sym 12 – 36 k. V 800 – 2000 A Up to 31. 5 k. A ABB

Series ‘U’ Disconnect Switch n Side Break n Horizontal & Vertical Pole Mounted n Series ‘U’ Disconnect Switch n Side Break n Horizontal & Vertical Pole Mounted n Optional Load Break n IEC n Manufactured ABB, Australia ABB© PTMV - 23 Voltage Rated Continuous Current Short Time Withstand Current 3 Sec. Sym 12 – 36 k. V 630 A 20 k. A ABB

Single Phase Air Switch Disconnects RBD & SLDT – Recloser Bypass Switch Series ‘SLSB’ Single Phase Air Switch Disconnects RBD & SLDT – Recloser Bypass Switch Series ‘SLSB’ 12 -24 k. V IEC 15 -36 k. V ANSI & IEC Series ‘SLD’ & DCD ABB© PTMV - 24 12 -36 k. V IEC & ANSI ITD – Inline Disconnect 15 -36 k. V ANSI SID, LSID & SLS 12 -38 k. V NEMA, ANSI & IEC ABB

Series ‘SLD’ & ‘DCD’ Disconnect Switches SLD/DCD: Single Phase Double Insulator n SLD/DCD: Horizontal Series ‘SLD’ & ‘DCD’ Disconnect Switches SLD/DCD: Single Phase Double Insulator n SLD/DCD: Horizontal & Vertical Pole Mounted n SLD – IEC; DCD - ANSI n SLD - Manufactured ABB, Australia n ABB© PTMV - 25 n DCD - Manufactured ABB, USA Voltage Rated Continuous Current Short Time Withstand Current 3 Sec. Sym 12 – 36 k. V 630 – 900 A 16 – 25 k. A ABB

ITD Disconnect Switches ITD: Inline Tension Single Phase Disconnect n Installs directly into the ITD Disconnect Switches ITD: Inline Tension Single Phase Disconnect n Installs directly into the distribution line n ANSI Standards n ITD - Manufactured ABB, USA n ABB© PTMV - 26 n 200 k. V BIL insulation to limit flashovers Voltage Rated Continuous Current Short Time Withstand Current 3 Sec. Sym 12 – 36 k. V 600 – 900 A 16 – 25 k. A ABB

SID, LSID, SLS Disconnect Switches n SID & SLS: Single Phase n LSID: Single SID, LSID, SLS Disconnect Switches n SID & SLS: Single Phase n LSID: Single Phase Load Break n SID & LSID: NEMA & ANSI n SLS: IEC n SID & LSID: Manufactured ABB, USA n SLS: Manufactured ABB, Australia n Good design for narrow installations and riser pole installations ABB© PTMV - 27 Voltage Rated Continuous Current Short Time Withstand Current 3 Sec. Sym 12 – 38 k. V 600 – 900 A 16 – 40 k. A ABB

Series RBD & ‘SLDT’ Bypass Switches RBD/SLDT: Single Phase Bypass Switch n RBD/SLDT: Horizontal Series RBD & ‘SLDT’ Bypass Switches RBD/SLDT: Single Phase Bypass Switch n RBD/SLDT: Horizontal & Vertical Pole Mounted n Main application – bypassing reclosers and voltage regulators to perform maintenance n SLDT – IEC; RBD - ANSI n SLDT - Manufactured ABB, Australia n ABB© PTMV - 28 n RBD - Manufactured ABB, USA Voltage Rated Continuous Current Short Time Withstand Current 3 Sec. Sym 12 – 36 k. V 630 – 900 A 16 – 25 k. A ABB

Series ‘SLSB’ n Single Phase By-Pass Disconnector n Integrated Fused Cutout for fault protection Series ‘SLSB’ n Single Phase By-Pass Disconnector n Integrated Fused Cutout for fault protection n IEC n Manufactured ABB, Australia ABB© PTMV - 29 Voltage Rated Continuous Current Interrupting Current 12 – 24 k. V 630 A 25 k. A ABB

Fused Cutouts n Type NCX Type ICX Series ‘V’ 12 -36 k. V IEC Fused Cutouts n Type NCX Type ICX Series ‘V’ 12 -36 k. V IEC Type LBU-II 7. 8 -38 k. V NEMA & ANSI ABB© PTMV - 30 Most complete portfolio in the world! 7. 8 -34. 5 k. V NEMA & ANSI Type EU & EUH 2. 6 -7. 8 k. V NEMA & ANSI ABB

Type NCX Fused Cutout n NEMA & ANSI n Manufactured ABB, USA n Dual-venting Type NCX Fused Cutout n NEMA & ANSI n Manufactured ABB, USA n Dual-venting to reach higher interrupting ratings Interrupting Current 7. 8 – 38 k. V ABB© PTMV - 31 Voltage Rated Continuous Current 100 – 300 A 2 – 20 k. A ABB

Type ICX Fused Cutout n Interchangeable Fuse Tube (with S & C, Chance, Cooper) Type ICX Fused Cutout n Interchangeable Fuse Tube (with S & C, Chance, Cooper) n Moisture Proof Fuse Tube reduces swelling over time n NEMA & ANSI n Manufactured ABB, USA Interrupting Current 7. 8 – 38 k. V ABB© PTMV - 32 Voltage Rated Continuous Current 100 – 300 A 8 – 16 k. A ABB

Type LBU-II Fused Cutout n Integrated Load Break Device to loadbreak safer, simpler and Type LBU-II Fused Cutout n Integrated Load Break Device to loadbreak safer, simpler and without special tools n NEMA & ANSI n Manufactured ABB, USA Interrupting Current 7. 8 – 34. 5 k. V ABB© PTMV - 33 Voltage Rated Continuous Current 100 – 300 A 6 – 20 k. A ABB

Series ‘V’ Fused Cutout n Single & Three Phase n IEC n Manufactured ABB, Series ‘V’ Fused Cutout n Single & Three Phase n IEC n Manufactured ABB, Australia Interrupting Current 12 – 36 k. V ABB© PTMV - 34 Voltage Rated Continuous Current 100 A 2 – 8 k. A ABB

Type EU and EUH n Enclosed Cutouts n Specialty cutout normally used in indoor Type EU and EUH n Enclosed Cutouts n Specialty cutout normally used in indoor and grid applications n Dropout or Non-dropout n NEMA & ANSI n Manufactured ABB, USA n Only major producer in the world Interrupting Current 2. 6 – 7. 8 k. V ABB© PTMV - 35 Voltage Rated Continuous Current 100 – 200 A 4 – 20 k. A ABB

ABB© PTMV - 36 ABB ABB© PTMV - 36 ABB