Interactive Intelligence Putting you in Control… Putting you in control… Controls V 1. 08 Sebastien Desmottes - Controls Development Engineer @ Plymouth (UK) TOSHIBAAI R CONDITIONING
Controls Product Contents Putting you in control… • • RBC-RDx-PE: Refrigerant Detection RBC-FDP 1 -PE: Fault Display Panel RBC-CRx-PE: Central Remote Controller RBC-WG 1 -PE: Windows Gateway RBC-WP 1 -PE: Windows Software RBC-EM 1 -PE: Energy Monitoring RBC-IK 1 -PE: Internet Kit TOSHIBAAI R CONDITIONING
Refrigerant Detection Putting you in control… Refrigerant Detection Indoor / Outdoor RBC-RD 1 -PE / RBC-RD 2 -PE TOSHIBAAI R CONDITIONING
Refrigerant Detection Contents Putting you in control… • • Why Refrigerant Detection Options available Indoor Unit: RBC-RD 1 -PE Outdoor Unit: RBC-RD 2 -PE System Layout Electrical Installation System Operation Installation Indoor / Outdoor Note: RBC-RD 1 -PE, RBC-RD 2 -PE TOSHIBAAI R CONDITIONING
Refrigerant Detection Why Refrigerant Detection? Putting you in control… • To protect personnel (EN 378) • To prevent environmental damage • To maintain system efficiency • Government Tax Incentives Note: RBC-RD 1 -PE, RBC-RD 2 -PE TOSHIBAAI R CONDITIONING
Refrigerant Detection Options Available Putting you in control… • Indoor Unit: RBC-RD 1 -PE – Interface box with remote refrigerant sensor & audible alarm • Outdoor Unit: RBC-RD 2 -PE – Interface box with internal sensor RBC-RDx-PE Note: RBC-RD 1 -PE, RBC-RD 2 -PE TOSHIBAAI R CONDITIONING
Refrigerant Detection Indoor Unit: RBC-RD 1 -PE Putting you in control… • • • Control box and screw caps Remote sensor/audible alarm assembly Front plate FCU interface cable Installation instructions Owners manual RBC-RD 1 -PE TOSHIBAAI R CONDITIONING
Refrigerant Detection Outdoor Unit: RBC-RD 2 -PE Putting you in control… • • • Control box with integral sensor and screw caps CDU interface cable Mounting bracket and screw Installation Instructions Owners Manual RBC-RD 2 -PE TOSHIBAAI R CONDITIONING
Refrigerant Detection RBC-RD 1 -PE System Layout Standard XY communication protocol Gateway: RBC-WG 1 -PE Front end PC running Windows control package (RBC-WP 1 PE). Displays alarm message and unit location. RBC-RD 1 -PE FCU Electrical Box XY Putting you in control… Isolating solenoid valves positioned in the gas and liquid lines (supplied by installer). PQ Interconnecting cable: control and Sensor. Hotel Room Metal oxide refrigerant detector. Low level position with audible alarm and 3 alarm set-points TOSHIBAAI R CONDITIONING
Refrigerant Detection RBC-RD 1 -PE System Layout Liquid Line Suction Line Communication cable Putting you in control… To Indoor Network Sensor located close to the floor monitors room air. Emits audible alarm when 1000 ppm refrigerant (R 407 C) detected. RD 1 box near unit sends signal to solenoid valves and indoor unit. TOSHIBAAI R CONDITIONING
Refrigerant Detection Electrical Installation RBCRD 1 -PE Putting you in control… • Mount the control box near to the indoor unit in a visible location • Mount the remote sensor assembly low down in the room. Maximum height from the floor surface should be 300 mm. Ensure 500 mm clearance around the sensor • Connect the remote sensor assembly to the control box using a 6 core cable • Connect the control box to a fused 240 V AC 1 amp supply • For RAV units connect the FCU interface cable to CN 17 on the indoor PCB • For MM units RBC-RD 1 -PE connect the FCU interface cable to CN 21 on the indoor TOSHIBAAI R CONDITIONING
Refrigerant Detection Electrical Installation RBCRD 2 -PE • • • Mount the control box inside the compressor housing of the outdoor unit Connect a 3 -core supply cable from the control unit to the electrical box on the outdoor unit. Ensure a 1 A fuse is fitted If one outdoor unit is used connect the CDU interface cable from the control unit to the electrical box on the outdoor unit. Locate the 3 ceramic fuses at the top of the electrical box From the top fuse remove the small red cable from the right side of the fuse. In its place fit the CDU interface Putting you in control… TOSHIBAAI R CONDITIONING
Refrigerant Detection Electrical Installation RBCRD 2 -PE Putting you in control… • For multiple outdoor units, each refrigerant detector must be connected in series to the unit in the inverter outdoor unit. The CDU interface cable is only used in the inverter unit • Connect each refrigerant detector using 3 -core cable to the L 1, N and earth terminals in each CDU. Each detector must be protected by a 1 amp 240 VAC fuse • Connect the AI terminals in the control units as shown in the diagram • To complete the series circuit connect the CDU interface cable to the RBC-RD 1 -PE inverter electrical box as described in the previous slide TOSHIBAAI R CONDITIONING
Refrigerant Detection System Operation Putting you in control… • Low Level Alarm – 250 ppm (RBC-RD 1 -PE Only): When the low level alarm limit is reached: – The Detector Active LED will be “ON” – The amber Low Level Alarm LED will start flashing – After 10 minutes, the Low Level Alarm LED will stop flashing and remain “ON” – B 5 fault code will be generated by the indoor unit RBC-RD 1 -PE unit will not shut down concentration drops – The indoor Note: If the refrigerant below 250 ppm the control box will self reset TOSHIBAAI R CONDITIONING
Refrigerant Detection System Operation Putting you in control… • High Level Alarm – 1000 ppm (RBC-RD 1/RD 2 -PE): When the high level alarm limit is reached: – – – The Detector Active and the Low Level Alarm LED’s will be “ON” – B 5 & B 6 fault codes will be generated by the indoor unit, 04 fault code will be generated by the outdoor unit – The indoor unit will shut down and the audible alarm will sound if an RD 1 was activated The red High Level Alarm LED will start flashing After 10 minutes, the High Level Alarm LED will stop flashing and remain “ON”. The red Shutdown LED will also come “ON” – The outdoor unit will shut down if an RD 2 was activated – The alarm volt free contacts will operate to control any suitable external device Note: The system must be manually reset RBC-RDx-PE TOSHIBAAI using the reset buttons on the control box R CONDITIONING
Refrigerant Detection System Operation Putting you in control… • Spill Alarm – 2200 ppm (RBC-RD 1/RD 2 -PE) When the spill alarm limit is reached: – – The Detector Active LED will be “ON” – B 6 fault code will be generated by the indoor unit if the refrigerant is detected in the room by RBC-RD 1 -PE – 04 fault code will be generated by the outdoor unit if the refrigerant is detected in the compressor housing by RBC-RD 2 -PE – – – The indoor unit will shut down and the audible alarm will sound if an RD 1 was activated After 10 seconds at the Spill Alarm limit, the Shutdown LED will come “ON” The Low Level Alarm & the High Level Alarm LED’s will start flashing The outdoor unit will shut down if an RD 2 was activated The “alarm” volt free contacts will operate to control any suitable external device connected to the control box RBC-RDx-PE Note: The system must be manually reset using the reset buttons on the control box TOSHIBAAI R CONDITIONING
Refrigerant Detection System Operation Putting you in control… • Sensor Failure (RBC-RD 1/RD 2 -PE) When the refrigerant sensor fails: – After 1 minute the Detector Active LED will go “OFF”, and the Low Level Alarm LED will come “ON” – B 5 fault code will be generated by the indoor unit. No fault code will be generated by the outdoor unit. The indoor or outdoor unit will not shut down – After 4 hours the Low Level Alarm LED will go “OFF” and the Shutdown LED will come “ON” – B 6 fault code will be generated by the indoor unit if the refrigerant leak is detected in the room by RBC-RD 1 -PE – A 04 fault code will be generated by the outdoor unit if the refrigerant is detected in the compressor housing by RBC-RD 2 -PE – – The indoor or outdoor unit will shutdown The “alarm” volt free contacts will operate to control any suitable external device connected to the control box RBC-RDx-PE Note: The system must be manually reset using the reset buttons on the control box after replacing the sensor TOSHIBAAI R CONDITIONING
Refrigerant Detection Refrigerant Mass Required Putting you in control… • RBC-RD 1 -PE : High Level Alarm Calculation based on a hotel room 5 m x 8 m x 2. 5 m. Density of R 407 C vapour at ambient pressure = 3. 518 kg/m 3. For high level alarm (unit shutdown) at 1000 ppm: Ppm concentration = 1000/1000000 = 0. 001 Grams of R 407 C = 5 m x 8 m x 2. 5 m x 3. 518 kg/m 3 x 0. 001 ppm/conc = 0. 3518 kg = 352 g • RBC-RD 1 -PE : Low Level Alarm Grams of R 407 C = 5 m x 8 m x 2. 5 m x 3. 518 kg/m 3 x 0. 00025 ppm/conc = 0. 0880 kg RBC-RD 1 -PE = 88 g TOSHIBAAI R CONDITIONING
Refrigerant Detection Refrigerant Mass Required Putting you in control… • RBC-RD 2 -PE : High Level Alarm Calculation based on the volume of the compressor housing = 0. 8 m 3 Density of R 407 C vapour at ambient pressure = 3. 518 kg/m 3. For high level alarm (unit shutdown) at 1000 ppm: Ppm concentration = 1000/1000000 = 0. 001 Grams of R 407 C = 0. 8 m 3 x 3. 518 kg/m 3 x 0. 001 ppm/conc = 0. 0028 kg = 2. 8 g RBC-RD 2 -PE TOSHIBAAI R CONDITIONING
Refrigerant Detection Installation Indoor / Outdoor Putting you in control… • Indoor Installation – Standard Grid Plate (BS 57533: 1995) – Standard Front Plate – Integral audible alarm mute button and refrigerant sensor RBC-RD 1 -PE TOSHIBAAI R CONDITIONING
Refrigerant Detection Installation Indoor / Outdoor Putting you in control… • Outdoor Installation • RBC-RD 2 -PE only available with MMS RBC-RD 2 -PE TOSHIBAAI R CONDITIONING
Fault Display Panel Putting you in control… Fault Display Panel RBC-FDP 1 -PE TOSHIBAAI R CONDITIONING
Fault Display Panel Contents Putting you in control… • Features • Installation TOSHIBAAI R CONDITIONING
Fault Display Panel Features Putting you in control… • Detect all Indoor Units faults • Attached in parallel with the Remote Controller (ABC) • LED to indicate activity (flashing at 1 s rate) • LED to indicate fault / no fault • Volt-free contact allows external signalling of the fault • Relay closed under fault free conditions • 09 Fault can be optionally filtered RBC-FDP 1 -PE TOSHIBAAI R CONDITIONING
Fault Display Panel Installation Putting you in control… • No external power supply needed as it is attached in parallel with the Remote Controller (ABC). • Fault filter – OFF: 09 faults are treated like any other fault code – ON: 09 faults are only reported after 3 hours RBC-FDP 1 -PE TOSHIBAAI R CONDITIONING
Central Remote Controller Putting you in control… Central Remote Controller RBC-CR 1 -PE, RBC-CR 64 -PE TOSHIBAAI R CONDITIONING
Central Remote Controller Contents Putting you in control… • Models • Features / Options • Installation TOSHIBAAI R CONDITIONING
Central Remote Controller Models Available Putting you in control… • RBC-CR 1 -PE – Control up to 16 Indoor Units • RBC-CR 64 -PE – Control up to 64 Indoor Units RBC-CRx-PE Note: RBC-CRx-PE cannot be used in conjunction with the Windows Gateway (WG 1) TOSHIBAAI R CONDITIONING
Central Remote Controller Options Available Putting you in control… • RBC-CR 1 -PE / RBC-CR 64 -PE – Compatible with Toshiba MMS and 4 Series Heat Pump – Compatible with 7 Day Timer (RBC-WT 1 -PE) • RBC-CR 64 -PE – – External switch (Input Shutdown) External timer Units can be grouped in Zones Two central Controllers can be used on the same XY Network RBC-CRx-PE Note: RBC-CRx-PE cannot be used in conjunction with the Windows Gateway (WG 1) TOSHIBAAI R CONDITIONING
Central Remote Controller Installation (RBC-CR 64 PE) Putting you in control… • All types of systems (MMS, SMi, Single split) can be connected to the same Central Remote Controller RBC-CR 64 -PE Note: RBC-CR 64 -PE cannot be used in conjunction with the Windows Gateway (WG 1) TOSHIBAAI R CONDITIONING
Interactive Intelligence Putting you in control… Building Management System RBC-WG 1 -PE, RBC-WP 1 -PE, RBC-EM 1 -PE, RBC-IK 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence BMS - Contents Putting you in control… • • • Link Between Products Windows Gateway Windows Software Energy Monitoring Internet Kit Note: RBC-WG 1 -PE, RBC-WP 1 -PE, RBCEM 1 -PE, RBC-IK 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Link Between Product ? Putting you in control… Internet / Intra net TOSHIBAAI R CONDITIONING
Link Between Controls Product Windows Gateway 1: 64 Putting you in control… • To control up to 64 Toshiba I. /D (MMS or RAV AI) units – Consists of: • One Gateway • One IEC Plug • Installation Instruction with functional profile RBC-WG 1 -PE Note: RBC-WG 1 -PE cannot be used in conjunction with any other Central Controller TOSHIBAAI R CONDITIONING
Link Between Controls Product Windows Software 1: 1024 Putting you in control… • To manage on one PC up to 1024 I/D i. e. 16 Gateways – Consists of: • One CD “Interactive Intelligence” • One hardware key • One owner's manual • PCI Card (Extension) RBC-WG 1 -PE Note: RBC-WG 1 -PE cannot be used in conjunction with any other Central Controller TOSHIBAAI R CONDITIONING
Link Between Controls Product Energy Monitoring Putting you in control… • RBC-EM 1 -PE is an add-on to RBC-WP 1 -PE – Consists of: • One power meter • Current Transformers x 3 • Installation Instructions RBC-EM 1 -PE Note: RBC-EM 1 -PE must be used in conjunction with RBC-WG 1 -PE, RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Link Between Controls Product Internet Kit 1: 5 Putting you in control… • RBC-IK 1 -PE is an add-on to RBC-WP 1 -PE – Consists of: • One key file CD “Interactive Intelligence” • License for 5 concurrent users RBC-WP 1 -PE Note: RBC-IK 1 -PE must be used in conjunction with RBC-WG 1 -PE, RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Putting you in control… Windows Gateway RBC-WG 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Windows Gateway 1: 64 Putting you in control… • • • Gateway using Lon. Works Technology Control up to to 64 I/D Auto Detect number of I/D automatically Functions of Central Remote Controller Ambient & Coil Temperatures available RBC-WG 1 -PE Note: RBC-WG 1 -PE is not compliant with Echelon. TOSHIBAAI R CONDITIONING
Interactive Intelligence Putting you in control… Windows Software Interactive Intelligence RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Windows Software 1: 1024 Contents • • • Features Installation Navigation (Schematics) Alarms Remote Connection Timed Operation and Optimised Start Frost Protection Module Data Logging Graphical view Backup / Restore of the complete System Customisation of Schematics Website Putting you in control… TOSHIBAAI R CONDITIONING
Interactive Intelligence Features Putting you in control… • Automated Configuration • Display and retransmission of Intelligent fault code • Unit location can be displayed on PC • Data and alarms logging • Timed operation under several schedule • Navigator (schematics) fully customisable • Hardware key protection and 100 4. 0, TOSHIBA RBC-WP 1 -PE Note: Compatible with Win 98 SE, Win NT access level Win 2000 and Win XP. R CONDITIONING AI
Interactive Intelligence Automatic Installation Putting you in control… BEFORE: AFTER: • Lon. Maker / Front End Software • PC & PCLTA 20 • Interactive Intelligence • Systems Integrator • PC RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Automatic Installation Putting you in control… • Auto-detect of the number of units on each Windows Gateway • Auto-detect how many Gateways on the network • Auto-detect how many Power Meters if any are present • Generates a Network database • Generates standard schematics for each units RBC-WP 1 -PE Note: The XY network connection must be checked. TOSHIBAAI R CONDITIONING
Interactive Intelligence Automatic Installation Putting you in control… • Opening system • Create schematics ? RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Automatic Installation Putting you in control… • Commissioned Devices ? (Windows Gateway / Power Meter) • Software looking for devices (Commissioned / Decommissioned) RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Automatic Installation Putting you in control… • Database generated • Able to rename Gateways • Able to rename Indoor Units • Able to decommission Gateways (right click on the Gateway) RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Navigation / Schematics Putting you in control… • Level 1 Schematic • Number of Gateways Click here to go to Level 2 (I/D attached to this Gateway) RBC-WP 1 -PE Note: LEVEL 1 Schematic TOSHIBAAI R CONDITIONING
Interactive Intelligence Navigation / Schematics Putting you in control… • Level 2 Schematic • Number of Indoor Units Click here to go to Level 3 (details of the settings) RBC-WP 1 -PE Note: LEVEL 2 Schematic TOSHIBAAI R CONDITIONING
Interactive Intelligence Navigation / Schematics Putting you in control… • Level 3 Schematic • Settings of the Indoor Unit Able to change the picture of the Indoor Unit RBC-WP 1 -PE Note: LEVEL 3 Schematic TOSHIBAAI R CONDITIONING
Interactive Intelligence Navigation / Schematics Putting you in control… • All models RBC-WP 1 -PE Note: LEVEL 3 Schematic TOSHIBAAI R CONDITIONING
Interactive Intelligence Alarms Putting you in control… • Indication: – Intelligent Fault. Code – Gateway/Indoor Unit RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Alarms Putting you in control… • Transmission – Print – Audio – Popup Window • Retransmission: – Fax – Email – Remote Site – GSM / Pager RBC-WP 1 -PE Note: Modem Internal / External Required on Supervisor. TOSHIBAAI R CONDITIONING
Interactive Intelligence Remote Connection Putting you in control… • Internet Kit Site – Site: RBC-WP 1 -PE + RBC-IK 1 -PE – Office: Internet Explorer • Remote Connection: – Site: RBC-WP 1 -PE – Office: RBC-WP 1 -PE WP 1 / IK 1 Office IE RBC-WP 1 -PERBC-WP 1 PE Note: Modem Internal / External Required on RBC-WP 1 -PE TOSHIBAAI Supervisor. R CONDITIONING
Interactive Intelligence Remote Connection Putting you in control… • Remote Connection – Able to: • Access system set-up • Edit / Modify schematics – Not able to access: • Driver set-up • Any plug-in (Optimised Start, Frost Protection Module, Energy Monitoring) RBC-WP 1 -PE Note: Modem Internal / External Required on Supervisor. TOSHIBAAI R CONDITIONING
Interactive Intelligence Timer – Option 1: Local Calendar Putting you in control… • Weekly Schedule – 300 Items – 24 Events in a day • Special Day RBC-WP 1 -PE Note: Local Calendar Option. TOSHIBAAI R CONDITIONING
Interactive Intelligence Timer – Option 2: Optimised Start Putting you in control… • Weekly Schedule RBC-WP 1 -PE Note: Optimised Start Option. TOSHIBAAI R CONDITIONING
Interactive Intelligence Timer – Option 2: Optimised Start Putting you in control… • Weekly Schedule • Optimised Start Option • User Friendly set-up RBC-WP 1 -PE Note: Optimised Start Option. TOSHIBAAI R CONDITIONING
Interactive Intelligence Timer – Option 2: Optimised Start • Enable a specific Temperature to be achieved at a specific time Putting you in control… Setpoint 23 °C DAY 1 20 °C 08: 50 09: 00 09: 10 time Setpoint 23 °C • Learning the room inertia to. DAY 2 determine when to start the Air Conditioning system DAY 3 20 °C Setpoint 23 °C 20 °C RBC-WP 1 -PE Note: Optimised Start Option. TOSHIBAAI R CONDITIONING
Interactive Intelligence Frost Protection Module Putting you in control… • Can enable the A/C and maintain in constant temperature in the event of low temperature being detected • Can stop the A/C when a temperature is achieved • Able to: – Turn On / Off – Change the Set Point – Change the Mode • Conditions can be entered which includes samples times, the trigger and reset points. RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Data Logging Putting you in control… • Record any data – Set. Point – Mode – Fan Speed – On / Off – Fault Codes – Demand Data – TA, TC RBC-WP 1 -PE Note: Max Log Time Base = 1 Day. TOSHIBAAI R CONDITIONING
Interactive Intelligence Graphical View Putting you in control… • Graphics from – Data logging – Colours and type of Graphic customisable - Zoom In / Out - Print RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Backup the complete system Putting you in control… • Backup system – Notes – Basic Configuration – Schematics – Data logging – Local Calendars – Script RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Restore the complete system Putting you in control… • Restore system – Notes – Basic Configuration – Schematics – Data logging – Local Calendars – Script RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation Putting you in control… • Site fully customisable • Examples: – United Kingdom Plymouth - Life Test – United Kingdom Leatherhead – UTC House Life Test – United Kingdom Glasgow – Airbels Road – France Nantes - System U – Austria – Office • Diagnostics (16 I/D and 32 I/D) RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK Plymouth Putting you in control… • Level 1 Schematic – 4 Gateways – 8 Different Systems RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK Plymouth Putting you in control… • Level 2 Schematic – MMS 14 HP – Energy Consumption available RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK Plymouth Putting you in control… • Level 2 Schematic – SMI 10 HP – Top view imported from Auto. CAD RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK Leatherhead Putting you in control… • Level 1 Schematic – UTC House RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK Leatherhead Putting you in control… • Level 2 Schematic – Top view imported from Auto. CAD - Blue and Red button to specify if the I. /D is cooling or heating RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK Leatherhead Putting you in control… • Level 2 Schematic – Only available for Service Engineers RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK Leatherhead Putting you in control… • Level 2 Schematic – Outdoor view imported from Auto. CAD RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK – Airbels. Road Putting you in control… • Level 1 Schematic – 2 Gateways – Trend System (Ventilation, hot water air handling plant, water levels, metering) RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK – Airbels. Road Putting you in control… • Level 2 Schematic – Gateway Ground & First floor – I/D Fault Codes RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK – Airbels. Road Putting you in control… • Level 2 Schematic – Gateway First & Second floor – I/D Fault Codes RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK – Airbels. Road Putting you in control… • Trend Control – Fan – Heaters – Water Tank – Metering RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK – Airbels. Road Putting you in control… • Air Handling Unit – Global view RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK – Airbels. Road Putting you in control… • Extract Fan – Global view RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK – Airbels. Road Putting you in control… • Heaters – Global view RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – UK – Airbels. Road Putting you in control… • Metering RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – FR Nantes Putting you in control… • Level 1 Schematic – Building view - 3 Gateways - 150 I/D RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – FR Nantes Putting you in control… • Level 2 Schematic – Top view imported from Auto. CAD - TS, TA reading - Heat / Cool reading RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – FR Nantes Putting you in control… • Special Schematic – Top view imported from Auto. CAD - Outdoor view - Display outdoor faults RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – AT Adelsberger Putting you in control… • Level 2 Schematic – Complete view of the system - Temperatures reading from Lon. Works sensors - Ventilation controlled with Interactive Intelligence I/D will stop if ventilation off RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – Diagnostics 16 Putting you in control… • Special Schematic – Able to see I/D data: • 01 to 16 • 17 to 38 • 39 to 48 • 49 to 64 RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Customisation – Diagnostics 32 Putting you in control… • Special Schematic – Able to see all the data from the Gateway RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Website - Home Putting you in control… • Home (basic feature of Interactive Intelligence) RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Website -Updates Putting you in control… • Updates • Interactive • LNS Driver • RGM • NDS • OZM • FPM • Node Utility • Checklist RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Website - FAQ Putting you in control… • FAQ • Commissioning… RBC-WP 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Putting you in control… Energy Monitoring RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Energy Monitoring Contents Putting you in control… • • • Features Installation of Power Meter Set-up the system View data Set-up the report RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Energy Monitoring Features Putting you in control… • Automatic Power Meter configuration • Calculation of Unit Running costs per indoor unit and system • Running costs based on a multiple tariffs • Running report based with different clients • Option for data export to CSV file (Compatible with Excel) • One Power Meter for one Outdoor Unit RBC-EM 1 -PE Note: Possibility to connect one Power Meter to 2 MMS Outdoor Units. TOSHIBAAI R CONDITIONING
Energy Monitoring Installation of Power Meter Putting you in control… • Installation 1: MMS 14 HP – Inverter Power Meter – Fix Power Meter – Current Transformer x 3 RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Energy Monitoring Installation of Power Meter Putting you in control… • Installation 2: MMS 26 HP – Inverter Power Meter – Fix Power Meter (1 Power Meter for 2 Fix Speed) – Current Transformer x 3 RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Energy Monitoring Installation of Power Meter Putting you in control… • Installation 3: SMI 10 HP – Inverter Power Meter – Current Transformer x 3 RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Energy Monitoring Set-up the system Putting you in control… • Set-up the database • Data Tree – System – Power Meter – Indoor Units RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Energy Monitoring Set-up the system Putting you in control… • Set-up Power Meters and Indoor Units – Link with Lon. Works database - Model names RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Energy Monitoring View Data Putting you in control… • System data: – Indoor Unit 1 – Indoor Unit 2 – Indoor Unit 3 – Indoor Unit 4 … RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Energy Monitoring Set-up the report Putting you in control… • Select: – Client – Tariff – Layout – Destination (Email or Printer) - Link (System) - Select Indoor Unit RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Energy Monitoring Set-up the report Putting you in control… • View the report: – Toshiba Standard Report with: - Client - Date - System reference RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Energy Monitoring Set-up the report Putting you in control… • Modify the report: – Able to change the complete layout - Able to import pictures RBC-EM 1 -PE TOSHIBAAI R CONDITIONING
Interactive Intelligence Putting you in control… Internet Kit RBC-IK 1 -PE TOSHIBAAI R CONDITIONING
Internet Kit Putting you in control… • Internet Kit is a license which enables a plug-in • Get connected to server using Internet Explorer • No software need to be installed on the client PC RBC-IK 1 -PE Click HERE Note: The license is for 5 concurrent users. TOSHIBAAI R CONDITIONING
Internet Kit Putting you in control… • 2 Levels of Access: – Remote A/C system monitoring - Full remote A/C system control and monitoring RBC-IK 1 -PE Note: The license is for 5 concurrent users. TOSHIBAAI R CONDITIONING
Internet Kit Putting you in control… • Internet Kit does not allow to modify the system set-up of Interactive Intelligence • 5 concurrent users can be connected in the same time • Each user can be allocated their own unique schematic • Alarms can be viewed remotely RBC-IK 1 -PE Note: The license is for 5 concurrent users. TOSHIBAAI R CONDITIONING
Interactive Intelligence Putting you in control… Any questions ? Internet / Intra net TOSHIBAAI R CONDITIONING
Interactive Intelligence Putting you in Control… Putting you in control… Thanks for your time… Controls Sebastien Desmottes - Controls Development Engineer @ Plymouth (UK) TOSHIBAAI R CONDITIONING
Interactive Intelligence Putting you in Control… Putting you in control… In Touch with Tomorrow TOSHIBA Controls Sebastien Desmottes - Controls Development Engineer @ Plymouth (UK) TOSHIBAAI R CONDITIONING