Скачать презентацию How to use a radiation monitor to reduce Скачать презентацию How to use a radiation monitor to reduce

7fa737daa87485ec47b98c33d8654ea9.ppt

  • Количество слайдов: 1

How to use a radiation monitor to reduce LISA noise levels Diana Shaul 1, How to use a radiation monitor to reduce LISA noise levels Diana Shaul 1, Henrique Araújo 1, Daniel Hollington 1, Alberto Lobo 2, Markus Schulte 1, Tim Sumner 1, Simon Waschke 1, Peter Wass 3 1 Imperial College London; 2 ICE/CSIC and IEEC; 3 University of Trento High energy cosmic ray and solar particle fluxes will charge up the LISA test masses (TMs). This charge will result in spurious electromagnetic forces acting on the TMs, disturbing their geodesic motion. The primary approach to minimise the impact of these forces is to discharge the TMs using the photoelectric effect. Unfortunately, the flux and energy spectrum of these high energy particles varies over time and therefore it is not easy to match charging and discharging rates, which would minimise the disturbances induced by charging. The gravitational reference sensor (GRS) can be used to measure the average charge accumulated, but not the shorter term variations in the charging rate. A radiation monitor (RM) can enable tracking of these changes. We describe how a RM could be used to reduce the charging disturbances for LISA and the plans for use of the RM on LISA Pathfinder (LPF), including an approach that could enable acceleration noise associated with charging to be effectively subtracted. 2. 3 Minimum Aims for RM on LPF 1. INTRODUCTION 1. 1 Charging Disturbances • Charge on the TM leads to Coulomb and Lorentz forces from interactions with GRS conducting surfaces and IMF, respectively. • These forces give rise to different types of disturbance: 1. Acceleration noise, due to fluctuations in e. g. voltage [1] 2. Modification of the effective stiffness describing TM-S/C coupling, due to position dependence of Coulomb forces [1] 3. Coherent Fourier components, due to time dependence of the amount of charge on the TM [2, 3] 1. 2 The Incident Flux • TM charging characteristics (net charging rate and charging shot noise) depend on the incident particle flux and its energy spectrum [4] • Higher energy particles => higher charge multiplicity events => more noise and higher net charging rates, compared with lower energy particles [4] • Solar Energetic Particle (SEP) energy spectra are softer than Galactic Cosmic Ray (GCR) spectra => A given particle flux will result in different TM charging characteristics, dependent on the proportion of SEP and GCR particles. [4] • The charging disturbances will also depend on the variability of the incident flux over time. This may give rise to sharp or gradual changes or periodicities in the charging rate, potentially resulting in spectral leakage, modulation of the coherent Fourier components and the masking of true signals in the LISA bandwidth. • Variations in flux: • Solar Cycle: 11 year period; 50% difference in charging rate between solar minimum and maximum [4, 5]; Gradual and sharp changes possible [6] • Solar rotation: ~ 27 day period; ~ 1 – 5 % GCR flux modulation [6] • Jovian synodic year: 13 months; <5% TM charging rate modulation [7] • SEPs: ~ 1 day– 1 week; ~100 -70000% (rare) TM charging rate increase [4] • Forbush Decreases: ~days; ~ few – 35% GCR flux modulation. [6] • Other GCR modulations: ~ iterate with each new direct TM measurement 1. Measurements = Synchronised GRS TM charging rate (noise) measurement with UV lamps off and acquisition of RM coincidence spectra 2. Scale the RM coincidence spectrum using the average RM singles rate over the same period. 3. Split the RM to TM charging noise transformation matrix into n segments, where n is the total number of direct TM charging rate (noise) measurements. The optimum positions of the segments will be derived using MC models. 4. Introduce n coefficients in the transformation matrix and solve for these coefficients, using the scaled coincidence spectra and direct TM charging measurements. 5. Repeat each time another suitable TM charging measurement is made to iteratively improve the transformation matrix. 6. To optimally improve this matrix, measurements should be made in as different solar conditions as possible. 1. 3 Charge Management 1. Charge measurement: Apply dither voltages to opposing electrodes and measure resultant TM displacement => average charging rate. Accuracy depends on the dither voltage amplitude, dither frequency, degree of freedom, and integration time. Typically, an accuracy of 104 e is reached in ~1 hour. This measurement does not give information on the charging shot noise nor the short term variability in the average charging rate. 2. TM Discharge: Use UV light to discharge via the photoelectric effect. Nominal science mode: closed loop control to match charging and discharging rates as closely as possible, to minimise disturbances. [11] 2. THE RADIATION MONITOR 2. 1 Aims • • • Independent monitor of incident particle fluxes 2 Silicon PIN diodes in Minimise/track disturbances due to charging telescopic arrangement, Help to manage disturbances Match charging/discharging rates Identify “DC” changes/coherent Fourier components Subtract Fourier components and charging noise Data : Coincidence spectrum, 10 mins integration Singles rates, 10 secs integration 2. 2 LPF RM Design (see e. g. [12] for more details) • Shielding to mimic TM shielding • Telescopic arrangement to enable SEP and GCR spectral discrimination within ~1 hr for events registering in both diodes • Minimum isotropic count rate >7 c/s, set to ensure: recognise small changes in flux associated with e. g. SEPs; RM shot noise ~ TM charging shot noise; detect periodic modulation in flux before exceeds LISA noise • Maximum count rate: large SEP: ~1500 c/s (isotropic), ~ 100 (coincident) • Nominal time bin counter <30 s (LPF: 1 m. Hz ≤ f ≤ 30 m. Hz) References: [1] [2] [3] [4] [5] [6] [7] [8] Schematic illustrating calibration of RM-TM transfer function 2. 4. 2 Direct measurement: TM charging rate, shot noise • The TM charging rate and shot noise may both be measured by applying a dither voltage to opposing electrodes and measuring the resultant TM displacement. [16] Rough guide to LPF requirements for sensitivity and integration time for direct TM measurements in different solar conditions Example measurement accuracy for 1 day integration and dither voltage of 1 V N. B. It still needs to be confirmed whether the LPF RM spectral resolution is sufficient to distinguish variations in GCR spectrum during mission lifetime. 2. 5 RM improvements for LISA • Electron monitor to track flux changes due to Jovian flux/early SEP warning • Multiple, distributed RMs on LISA S/C to a/c for anisotropies in flux during SEP events, Forbush decreases etc. . • Real-time, on-board feedback between RM and GRS to: calibrate RM; match charging and discharging rates; to benefit from early SEP warning • Improved spectral discrimination Shaul DNA et al. , Class. Quantum Grav. 22, S 297 (2005). Shaul DNA et al. , International Journal of Modern Physics D 14, 51 (2005). Shaul DNA et al. , Class. Quantum Grav. 21, S 647 (2004). Araújo HM et al. , Astroparticle Physics 22, 451 (2005). Wass PJ et al. , Class. Quantum Grav. 22, S 311 (2005). Jursa AS (ed. ), Handbook of geophysics and the space environment, 4 th edn. , Air Force Geophysics Laboratory (1985). Shaul DNA et al. , 6 th International LISA Symposium, AIP Conf. Proc. 873, 172 (2006). Blake JB et al. , in preparation (2008). [9] [10] [11] [12] [13] [14] [15] [16] Quenby J. , et al. , JGR, in publication (2008) Starodubtsev et al. , Ann. Geophys 24, 779 (2006). Shaul DNA et al. , International Journal of Modern Physics D, in publication (2008). Wass PJ, Ph. D thesis (2007). Vocca, H. , et al. , Class. Quantum Grav. 22, S 319 (2005). Vocca, H. , et al. , Class. Quantum Grav. 21, S 665 (2004). Grimani, C. et al. , Class. Quantum Grav. 22, S 327 (2005). Weber, W. , Private Communication (2007).