Home EMC Compliance systems Emissions EN series Def Stan FCC As/Nz and EMC Pre-Compliance Home EMC Compliance systems Emissions EN series Def Stan FCC As/Nz and EMC Pre-Compliance systems Immunity IEC 61000 -4 -series and RF monitors and meters Harmonics & Flicker Safety at work IEC 61000 -3 -2 IEC 61000 -3 -3 ICNIRP All from the Experts at Laplace Instruments Ltd

Selector Make emissions measurements to check emission compliance? Test for susceptibility/immunity? Or both? Test Selector Make emissions measurements to check emission compliance? Test for susceptibility/immunity? Or both? Test for Harmonics & Flicker compliance? Looking for ancillaries such as reference sources, antennas, LISNs etc…. . ? See the overview and selector chart

EMC Compliance Testing – the essential guide Routemap Emissions Susceptibility (immunity) Harmonics & Flicker EMC Compliance Testing – the essential guide Routemap Emissions Susceptibility (immunity) Harmonics & Flicker RFG- core system SA 1000 (1 GHz) or SA 3000 (3 GHz) analyser RF 100 probes IEC 61000 -4 -3 IEC 61000 -4 -2, 4, 5, 11 IEC 61000 -4 -6 Radiated RF LF effects Conducted RF SA 1020 pre-amp RF 1000 (1 GHz) or RF 2000 (2 GHz) or RF 3000 (3 GHz) Synthesiser Conducted Radiated All EMC emission standards Appliance? EN 55014 LISN or PLIP Luminaire? EN 55015 If emissions Broadband? RF 800 or RF 915 Pre-selector RF Absorbing clamp EUT size……… Large and small RF 200, RF 230 or CTS 011 miniature antenna RF 600 and RF 700 OATS Ambient filters Anechoic chamber ERS Emissions Reference Sources LETIS or AC 2000 analyser CDNs RF 11 xx, RF 12 xx or RF 13 xx Power Amplifiers RF 300 large Loop antenna All other EMC standards RFIC-46 RF 200 RF 230 antenna Small? Filtered feeds AC 1000 clean Power source ECOMPACT 4 Integrated test system CDNs ESD Test cell Lc 300/2 or Lc 600 30 MHz – 3 GHz Clamps Camera & lighting Loops Anechoi c chambe r IEC 61000 -3 -2 IEC 61000 -3 -3 Key Information Laplace product Incl PC software Incl. in CLIENTS LETIS RFP-04 CE Field probe +fibre link option

HARMONICS & FLICKER H&F , rds tanda he s s of t 00 -4 HARMONICS & FLICKER H&F , rds tanda he s s of t 00 -4 -15 rsion st ve nd IEC 610 late o the 000 -4 -7 a ted t upda ing IEC 61 Now d inclu Compliant with: IEC 61000 -3 -2 IEC 61000 -3 -3 AC 2000 A AC 1000 A Clean power source. Provides up to 1 k. W (4 A) of pure sine mains power. Output harmonic content: <0. 1% THD Harmonic & Flicker analyser. Features: Automatic testing Automatic calculation of ‘variable’ limits Self contained instrument PC interface included

Emissions………… Emission selector Emissions analyser Radiated – test cell Radiated – Antenna Radiated – Emissions………… Emission selector Emissions analyser Radiated – test cell Radiated – Antenna Radiated – Large Loop Antenna Radiated – Reference sources Radiated – Pre-amplifier Radiated – Near field probes or ? Conducted

Conducted emissions Conducted selector Analyser and software LISNs Voltage probes Conducted emissions Conducted selector Analyser and software LISNs Voltage probes

EMC analysers and software SA 1000 -a High performance EMC analysers……. SA 1002………… 9 EMC analysers and software SA 1000 -a High performance EMC analysers……. SA 1002………… 9 KHz – 1 GHz SA 3000………… 9 KHz – 3 GHz Compliant detectors (Pk, QP and Average) Pre-loaded limits in software. All results in Windows environment. Easy to use…. USB interface to any PC Input connects to any Laplace antenna or transducer. See also the RF 910 and RF 915 pre-selectors. Conducted Pre-selector Radiated Antennas LISNs Test Cell Voltage probes Reference sources

Test cells Cells It does not get any easier than this………. . * Quick Test cells Cells It does not get any easier than this………. . * Quick * Compact * Convenient Radiated Emissions to 3 GHz Radiated Immunity to 3 GHz Select Emissions or Immunity Two sizes: ……. Lc 300/2: up to 30 cm cube EUT, benchtop model Lc 600: up to 60 cm cube EUT, floor standing Both provide IEC 61000 -4 -3 testing to over 10 V/m More details……

Access door open to EUT area Lc 300/2 -outer System configured with: • SA Access door open to EUT area Lc 300/2 -outer System configured with: • SA 1000 emissions analyser • RF 2000 synthesiser • RF 1100 power amplifier • LETIS • RF 1200 power amplifier More details…… Lc 300/2

Lc 300/2 -filter Filter connection plate to External services Access door open to internal Lc 300/2 -filter Filter connection plate to External services Access door open to internal filter connections. Aperture (hidden) provides access to EUT volume More details……

Advantages of test cells Advantages specific to Lapla. Cellnotes • Eliminate ambient • Known Advantages of test cells Advantages specific to Lapla. Cellnotes • Eliminate ambient • Known calibration • Compact size • Ease of use • Located in your own lab. • Convenience • Not dependant on the weather! • Smallest size • Better field uniformity GTEM field - poor uniformity Lapla. Cell field - far better uniformity • Impedance matched for better results • Free space impedance is 377 ohm (Ideal) • GTEM cells are 50 ohm systems • Laplacell features impedance conversion to 200 o • Much closer to ideal • Complies with IEC 61000 -4 -20 • Latest standard for the calibration of cells • Built-in field sensor • Save cost and complexity Test chamber option

Integrated system for immunity testing to IEC 61000 -4 -3 in test chamber Test Integrated system for immunity testing to IEC 61000 -4 -3 in test chamber Test chamber RF 200 and RF 230 antennas Field sensor (RFP-04 CE) With RS 232 fibre optic interface (PCLK) Chamber Optional EUT monitoring Fibre optic cable (FOLK) EUT Antenna Synthesiser/ signal genny Power amplifier Switch Unit RF 1000, RF 2000 or RF 3000 with –RH option (External sensor) RF 11 xx RF 12 xx or RF 1300 LETIS System controller System software

Pre-selector units RF 910 and RF 915 As specified by CISPR 16 and recommended Pre-selector units RF 910 and RF 915 As specified by CISPR 16 and recommended for conducted emission measurements if the EUT produces broadband noise. RF 1000 or RF 2000 These pre-selectors effectively pre-filter the incoming signal such that the analyser input is not overloaded by broadband energy. Not required if EUT produces narrowband noise. RF 910 covers band B (150 KHz – 30 MHz) RF 915 covers bands A and B (9 KHz – 30 MHz) Photo shows RF 910 below SA 1000 and PC

Emissions Reference Sources ERS These sources can be used to simply check an established Emissions Reference Sources ERS These sources can be used to simply check an established site prior to measurements, or To calibrate an unknown site. Note that the dominant source of measurement uncertainty for radiated emissions is the test site! ERS EMC 3. 5 1 GHz reference source 3. 5 GHz reference source. Fully traceable to NPL Extremely compact Only 12 x 7 x 14 cm 2 MHz spacing Provides auto site calibration when used with SA 1002 or SA 3000 10 or 50 MHz spacing Remote control option

Antennas A range of antennas to cover most requirements. Antennas ARA Active receive antenna Antennas A range of antennas to cover most requirements. Antennas ARA Active receive antenna Compact, but same sensitivity as larger antenna RF 300 Large loop antenna (Van Leen Loop) To CISPR 15 CTS 011 RF 200 Broadband antenna 30 MHz – 1 GHz Standard EMC antenna For use on OATS or in test chambers Very small! About the size of your hand. For use in confined spaces

RF meters and detectors TDM-200 RF power density meter. Trifield Internal antenna Ideal for RF meters and detectors TDM-200 RF power density meter. Trifield Internal antenna Ideal for RF signal strength field surveys. 0. 5 MHz to 3 GHz TBM-100 Broadband meter An Electric field meter, Gaussmeter and RF field strength meter all in one small unit. Monitor and measure the field from AC power lines, video displays, ovens, LANs and mobile phones Gaussmeter: 40 Hz – 500 Hz Electric field meter: 40 Hz – 100 KHz RF field meter: 100 KHz – 2. 5 GHz T-MA-P Personal RF hazard warning detector Provides an audible warning if the RF field is close to the ICNIRP recommended limits Essential for all who work close to RF transmittersand cell base stations

LISNs and Voltage Probes LISN - Line Impedance Stabilisation Network Commercial range complies with LISNs and Voltage Probes LISN - Line Impedance Stabilisation Network Commercial range complies with CISPR 16 Def Stan, Mil Spec and CISPR 25 versions also available Up to 4 lines Up to 100 A/phase Commercial range includes transient limiters PLIP Voltage probe As specified by CISPR 16 For use when LISN is not appropriate. Includes opto-isolation and high voltage, fused connecting clips

Immunity testing Immunity selector IEC 61000 -4 -2 ESD ONYX 16 simulator IEC 61000 Immunity testing Immunity selector IEC 61000 -4 -2 ESD ONYX 16 simulator IEC 61000 -4 -3 Radiated RF Lapla. Cell and ancillaries IEC 61000 -4 -4 EFT ECOMPACT 4 IEC 61000 -4 -5 Surge ECOMPACT 4 IEC 61000 -4 -6 Conducted RF RFIC 46 system + CDNs IEC 61000 -4 -8 Power Mag. Field ECOMPACT 4 (option) IEC 61000 -4 -9 Pulsed Mag. Field ECOMPACT 4 (option) IEC 61000 -4 -11 Dips and Interrupts ECOMPACT 4 Lapla. Cell systems RFIC systems ECOMPACT 4 Standard system

RF Immunity test RFI test-a IEC 61000 -4 -3 requires EUT to be immersed RF Immunity test RFI test-a IEC 61000 -4 -3 requires EUT to be immersed in strong modulated RF fields over the range 80 MHz – 1 GHz, or higher! The specified techniques are fully incorporated into The Laplace test system comprising a Lapla. Cell, system controller and power amplifier. See CLIENTS for total automated solutions. Note that these systems work equally well with test chambers (FAC or SAC or stirred mode). EUT Feedback Any standard PC USB RF 1000, RF 2000 or RF 3000 RF 1100 and/or RF 1200 or RF 1300 RF Power RF level feedback

Pre-amp & near field probes RF 100 & SA 1020 RF 100 near field Pre-amp & near field probes RF 100 & SA 1020 RF 100 near field probe set Essential tool for the location of emission sources and identification of emission frequencies. SA 1020 Pre-amplifier 20 d. B gain, flat characteristic from 9 KHz to over 1 GHz. Internal PP 3 battery provides 30 hour run time.

Compact Immunity Test System IEC 61000 -4 -6 CIT-10 Model RFIC 46 Includes: Function Compact Immunity Test System IEC 61000 -4 -6 CIT-10 Model RFIC 46 Includes: Function generator Signal Generator RF Millivoltmeter RF power amplifier EUT monitoring Feedback monitoring Wide range of optional ‘Versatile’ and ‘Enhanced’ CDNs available • PC Controlled via USB • Windows software included • 100 KHz – 300 MHz (Exceeds requirements of the standard • 25 W power amplifier… more than enough for most applications • Totally integrated system… very quick and easy to use.

Combined Low cost Immunity and Emissio. Ns Test CLIENTS Systems. CLIENTS System shown will Combined Low cost Immunity and Emissio. Ns Test CLIENTS Systems. CLIENTS System shown will provide automated measurements of emissions and RFI testing up to 2 GHz. The LETIS (Laplace EMC Test Integration System) provides all necessary interconnections and switching under software control. Any standard PC SA 1002 or SA 3000 Emissions analyser RF 2000 Immunity controller RF 1100 30 -1000 MHz P. A. LETIS System integrator RF 1200 0. 8 -2 GHz P. A.

RF Power Amplifiers Power amps A range of RF power amplifers for use with RF Power Amplifiers Power amps A range of RF power amplifers for use with test cells RF 1100 RF 1170 RF 1200 RF 1240 RF 1300 25 W 30 MHz to 1 GHz 70 W 30 MHz to 1 GHz 12 W, 0. 8 GHz to 2 GHz 40 W, 0. 8 GHz to 2 GHz 10 W, 0. 8 GHz to 3 GHz These amplifiers will provide well in excess of the required fields for IEC 61000 -4 -3 industrial standards inside the Lapla. Cells

Immunity test controllers Synthesiser RF 1000, 30 MHz – 1 GHz RF 2000, 30 Immunity test controllers Synthesiser RF 1000, 30 MHz – 1 GHz RF 2000, 30 MHz – 2. 2 GHz RF 3000, 30 MHz – 3 GHz Functions: • Signal generation and control • Field strength level control • EUT monitoring • Windows interface via USB • Flexible test setup • Full recording and display of results • Serial interface for remote sensor These controllers will provide all control and interface requirements for sophisticated immunity

LETIS Laplace EMC Test Integration System. Letis RS 232 LETIS acts as a PC LETIS Laplace EMC Test Integration System. Letis RS 232 LETIS acts as a PC controlled switching unit to automatically route the signals between the cell, the power amplifiers and the system controller. Avoids mistakes, saves time and allows long term unattended operation. Control To PC To Cell USB RF Laplace Instruments Ltd EMISSIONS Auto 1 2 USB Power IMMUNITY Range 1 RF 1100 connections To RF 2000 Manual Range select To emissions analyser LETIS - Laplace EMC Test Integration System RF connection to cell Range 2 RF 1200 connections Made in UK

EMC analysers and software SA 1000 -b High performance EMC analysers……. SA 1002………… 9 EMC analysers and software SA 1000 -b High performance EMC analysers……. SA 1002………… 9 KHz – 1 GHz SA 3000………… 9 KHz – 3 GHz Compliant detectors (Pk, QP and Average) Pre-loaded limits in software. All results in Windows environment. Easy to use…. Serial interface to any PC. Input connects to any Laplace antenna or transducer. See also the RF 910 and RF 915 pre-selectors. Conducted Radiated Pre-selector Antennas LISNs Test cell Voltage probes Reference sources

RF Immunity test RFI test-b IEC 61000 -4 -3 requires EUT to be immersed RF Immunity test RFI test-b IEC 61000 -4 -3 requires EUT to be immersed in strong modulated RF fields over the range 80 MHz – 1 GHz. The specified techniques are fully incorporated into The Laplace test system comprising a Lapla. Cell, system controller and power amplifier. See CLIENTS for total automated solutions. Note that these systems work equally well with test chambers (FAC or SAC or stirred mode). EUT Feedback Any standard PC USB RF 1000 or RF 2000 or RF 3000 RF 1100 and/or RF 1200 or RF 1300 RF Power RF level feedback

About Laplace…. Founded in Laplace 1988 test equipment ØSpecialises in EMC Join the experts! About Laplace…. Founded in Laplace 1988 test equipment ØSpecialises in EMC Join the experts! ØNOT linked to any other company ØCustomer base worldwide ØGlobal distributor network ØOver 2000 EMC test systems in operation ØOver 50 Lapla. Cell systems sold. ØAll main products and software developed in-house ØWe ALWAYS support all our customers direct… regardless of age of system (and all free of charge!) ØContinuous development program… new hardware and software to match