HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Functionality BDTP HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Functionality BDTP TCP/IP *BDTP = Beijer Data Transport Protocol ( UDP with handshake ) Mitsubishi Electric – E 1000 BDTP, October 2007

HMI /// E 1000 /// HMI /// E 1000 /// HMI Advanced BDTP Functions HMI /// E 1000 /// HMI /// E 1000 /// HMI Advanced BDTP Functions • Server Alarms Defined Alarms in a server automaticaly will be transfert to the relevant clients • Automatical Reboot Function • Automatic start of the clients in case the server start up (boot procedure) Mitsubishi Electric – E 1000 BDTP, October 2007

HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP with 1 HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP with 1 PLC 192. 168. 1. 200 A PC is node in the network And can manage the up/download of projects 192. 168. 1. 3 A client can access to a controller only over a server 192. 168. 1. 10 This terminal must be a server To can access to the controler BDTP Server Client 192. 168. 1. 23 Mitsubishi Electric – E 1000 BDTP, October 2007 Client 192. 168. 1. 36

HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP same Protocoll HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP same Protocoll several PLC´s 192. 168. 1. 3 This terminal is a client with access to both controler Access to controler 1 and 2 192. 168. 1. 1 This terminal is Client/Server with access to all the other terminals and controler exception controler 3 because of the missing server Access to Controler 1 and 2. 192. 168. 1. 2 This terminal hasn´t access to the other controler because it´s only a server. Access only to controler 2. 192. 168. 1. 4 This terminal is a client with access to both controler. Access to controler 1 -3 3 BDTP Client/ Server No. 1 No. 2 Mitsubishi Electric – E 1000 BDTP, October 2007 Client No. 3

HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP unequal Protocoll HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP unequal Protocoll several PLC´s 192. 168. 1. 1 This terminal is a client with driver ”M” It can access only to server with the same driver Access to controler 1 Because of different driver no access to controler 2 and also to terminal 3 because of the missing server service. 192. 168. 1. 2 This terminal is a server with driver ”S”. It has no access to other controller because of the missing client service. Access only to controler 2 192. 168. 1. 3 This terminal is a server with driver ”S”. It has access to all the server with the same driver Access only to controler 2 BDTP Client/ Server No. 1 No. 2 Mitsubishi Electric – E 1000 BDTP, October 2007 Client No. 3 192. 168. 1. 4 This terminal is a client with driver ”M”. It has access to all the server with the same driver Access only to controler 1+3

HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Example (Structure HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Example (Structure of a BDTP-Network) Terminal 1 Terminal 2 Terminal 3 192. 168. 1. 10 192. 168. 1. 4 192. 168. 1. 1 Client/ Server 192. 168. 1. 3 Client/ Server RS 422 No. 1 192. 168. 1. 2 Mitsubishi Electric – E 1000 BDTP, October 2007 Client Ethernet No. 2

HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Example (Client/Server HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Example (Client/Server Setup Terminal 1) 192. 168. 1. 1 Define all the server addresses in the BDTP-Network Don´t define the own address!! Default Einstellungen Mitsubishi Electric – E 1000 BDTP, October 2007

HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Example (Client/Server HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Example (Client/Server Setup Terminal 2) 192. 168. 1. 3 Mitsubishi Electric – E 1000 BDTP, October 2007

HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Exampe (Client HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Exampe (Client Setup Terminal 3) 192. 168. 1. 4 Mitsubishi Electric – E 1000 BDTP, October 2007

HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Example (indicated HMI /// E 1000 /// HMI /// E 1000 /// HMI BDTP Example (indicated operandadresing) • In the BDTP client settings serverconections will be declared. • By the serverdeclaration, each of them got an index • The addressing of operands of a PLC, which is not direct connected to the relevant terminal has to bedeclared according to the follow syntax INDEX > OPERAND e. g 2>Y 10 Output Y 10 of the PLC, which server is located in terminal with the IP address 192. 168. 1. 3 (Index 2, see“BDTP-Server-connections”). Mitsubishi Electric – E 1000 BDTP, October 2007