a6e6286a884d91895da8a3b04baaf55b.ppt
- Количество слайдов: 42
GS 2060/TL 260 GS Product Technical Training 2 -Way Wireless Security Suite
GS 2060/TL 260 GS – Product Overview 2 -Way Wireless Security Suite
GS 2060 GSM/GPRS Wireless Alarm Communicator Overview: The GS 2065 provides primary or backup GSM/GPRS communication for Power Series PC 1864/1832/1616 control panels Specifications: • Dimensions : 3. 937"x 5. 875"x 0. 625" (100 mmx 15 mm) • Weight : 310 g • Antenna Gain : 2 db • Input Voltage : 11. 1 to 12. 6 V (from the Panel Bell output) • Current Draw : 65 m. A at 12 V (400 m. A during the GSM transmission) • Operating Environment : 5 º C to 40º C (40º F to 104º F) 2 -Way Wireless Security Suite
GS 2060 GSM/GPRS Wireless Alarm Communicator Features: • Back up and primary GSM/GPRS alarm communication • Panel remote uploading/downloading support via GSM/GPRS • Individual Periodic Test Transmission via GSM/GPRS • Supervision heartbeats via GSM/GPRS • 128 -bit AES encryption over GSM/GPRS • Full event reporting • SIA format • PC-Link connection • SIM card included • Signal strength and trouble display • Activating and initializing through Connect 24 • Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz 2 -Way Wireless Security Suite
GS 2060 GSM/GPRS Wireless Alarm Communicator Compatible Control Panel & Cabinet Control panel: Cabinet: Power Series PC 1864/1832/1616 version 4. 1 and higher PC 5003 C and PC 4050 C Compatible Receivers: Sur-Gard System I Receiver: version 1. 10 and higher Sur-Gard System II Receiver: version 2. 00 and higher Sur-Gard SG-DRL 3 -IP: version 2. 20 and higher (for Sur-Gard System III Receiver) Product Model and Accessories: GS 2060 GS-USA: GS 2060 GS-CDN: GS-15 ANTQ: GS-25 ANTQ: GS-50 ANTQ: For US market with AT&T SIM card For Canada market with Roger SIM card Antenna Extension Kits with 15 feet cable Antenna Extension Kits with 25 feet cable Antenna Extension Kits with 50 feet cable 2 -Way Wireless Security Suite
TL 260 GS Internet and GSM/GPRS Dual-Path Alarm Communicator Overview: The TL 260 GS is an Internet and GSM/GPRS Dual-Path alarm communication for Power Series PC 1864/1832/1616 control panels Specifications: • Dimensions : 3. 937"x 5. 875"x 0. 625" (100 mmx 150 mmx 18 mm) • Weight : 320 g • Antenna Gain : 2 db • Input Voltage : 11. 1 to 12. 6 V (from the Panel Bell output) • Current Draw : 100 m. A at 12 V (400 m. A during the GSM transmission) • Operating Environment : 5 º C to 40º C (40º F to 104º F) 2 -Way Wireless Security Suite
TL 260 GS Internet and GSM/GPRS Dual-Path Alarm Communicator Features: • Fully redundant Internet and GSM/GPRS dual-path alarm communication • Integrated call routing • Panel remote uploading/downloading support via GSM/GPRS and Internet • Individual Periodic Test Transmission via GSM/GPRS and Internet • Supervision heartbeats via GSM/GPRS and Internet • 128 -bit AES encryption via GSM/GPRS and Internet • Full event reporting • SIA format • PC-Link connection • SIM card included • Signal strength and trouble display • Activating and initializing through Connect 24 • Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz 2 -Way Wireless Security Suite
TL 260 GS Internet and GSM/GPRS Dual-Path Alarm Communicator Compatible Control Panel: Control panel: Cabinet: Power Series PC 1864/1832/1616 version 4. 1 and higher PC 5003 C and PC 4050 C Compatible Receivers: Sur-Gard System I Receiver: version 1. 10 and higher Sur-Gard System II Receiver: version 2. 00 and higher Sur-Gard SG-DRL 3 -IP: version 2. 20 and higher (for Sur-Gard System III Receiver) Product Model and Accessories: TL 260 GS-USA: TL 260 GS-CDN: GS-15 ANTQ: GS-25 ANTQ: GS-50 ANTQ: For US market with AT&T SIM card For Canada market with Roger SIM card Antenna Extension Kits with 15 feet cable Antenna Extension Kits with 25 feet cable Antenna Extension Kits with 50 feet cable 2 -Way Wireless Security Suite
UL Approval List GS 2060 GSM/GPRS Wireless Alarm Communicator TL 260 GS Internet and GSM/GPRS Dual-Path Alarm Communicator UL Commercial Burglary • Listed as a primary communication channel (heartbeats must be enabled) • Listed as a back-up in conjunction with the POTS (daily test transmission) • Used as Dual Signaling Line Communication System (redundancy must be enabled) • Used as Standard Line Security and Encrypted Line Security System (heartbeats and encryption must be enabled) UL Residential Burglary and Fire • Listed as a primary communication channel (monthly test transmission) • Listed as a back-up in conjunction with the DACT (monthly test transmission) 2 -Way Wireless Security Suite
ULC Approval List GS 2060 GSM/GPRS Wireless Alarm Communicator TL 260 GS Internet and GSM/GPRS Dual-Path Alarm Communicator ULC Commercial Burglary and Fire • Listed as a passive communication module with Security Level P 1, P 2 and P 3 (redundancy must be enabled) • Listed as a active communication module with Security Level A 1 -A 4 (heartbeats and encryption must be enabled) ULC Residential Burglary and Fire • Listed as a primary communication channel (daily test transmission) • Listed as a back-up in conjunction with the DACT (daily test transmission) 2 -Way Wireless Security Suite
UL/ULC Listed Installation – Commercial Supervisory/Test Transmission Requirements Applications Communicator Setup Mode GS 2060 UL Commercial Burglary Primary UL Commercial Burglary TL 260 GS Primary Channel Backup Channel 200 ms Daily Backup Daily Optional ULC Commercial Fire Active 180 ms Daily ULC Commercial Fire Passive Daily ULC Commercial Burglary Active 180 ms Daily ULC Commercial Burglary Passive Daily NOTE: Proper Supervisory/Test Transmission intervals could be pre-set with the profile in Connect 24 database for applicable installations. 2 -Way Wireless Security Suite
UL/ULC Listed Installation – Residential Supervisory/Test Transmission – Requirements Applications Communicator Setup Mode GS 2060 UL Residential Fire Primary UL Residential Fire TL 260 GS Primary Channel Backup Channel Monthly Backup Monthly Optional UL Residential Burglary Primary Monthly UL Residential Burglary Backup Monthly Optional ULC Residential Fire Active Daily Optional ULC Residential Fire Passive Daily Optional ULC Residential Burglary Active Daily Optional ULC Residential Burglary Passive Daily Optional NOTE: Proper Supervisory/Test Transmission intervals could be pre-set with the profile in Connect 24 database for applicable installations. 2 -Way Wireless Security Suite
GS 2060/TL 260 GS – Installation and programming 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation BEFORE YOU BEGIN Have the following ready before installation: • • PC 1864/1832/1616 Control panel with backup battery Battery connection harness PK 5500 keypad with battery Screwdriver Prior to installing a GS 2060 and TL 260 GS, contact your monitoring station to determine if it is a master reseller or visit www. connect 24. com and become an authorized dealer. In both instances, you will acquire a Profile Number, Installer ID Number and an Installer Password. Please NOTE: 1. You need to activate the SIM card and initialize the communicator (step 1) 24 HOURS BEFORE INSTALLATION. 2. All options of the communicator only could be programmed through Connect 24 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Summary of Installation Steps Step 1 – Initialize an account via Connect 24 Website (www. connect 24. com) Step 2 – Install and wire the communicator to the control panel (on-site) Step 3 – Load the programming and test for best signal strength location Step 4 – Program communication options on the control panel via keypad Step 5 – Test communication 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 1 – Initialize an account via Connect 24 Website (www. connect 24. com) Login to Connect 24 website by using Installer ID and Password to initialize an account • Select Profile Number • Select Product Model • Enter SIM card number • Enter DNIS number (if necessary) • Enter Account Code • Select GPRS Periodic Test Transmission Interval (if necessary) • Select Supervisory Type (if necessary) • Enable DHCP (if necessary) • Enter IP Address (TL 260 GS only when the installation is static IP) • Enter Subnet Mask Address (TL 260 GS only when the installation is static IP) • Enter Gateway Address (TL 260 GS only when the installation is static IP) • Select Ethernet Periodic Test Transmission Interval (if necessary) • Select Rate Plan • Confirm information and submit activation application NOTE: You still can remotely change these options later via Connect 24 website. 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 1 – 1 Select Profile Number 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 1 – 2 Select Module Number 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 1 – 3 Enter SIM Number 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 1 – 4 • Enter DNIS number • Enter Account Code • Select Supervisory Type • Enable DHCP (if necessary) 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 1 – 5 • Enter IP Address (TL 260 GS only) • Enter Subnet Mask Address (TL 260 GS only) • Enter Gateway Address (TL 260 GS only) 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 1 – 6 • Select Plan Rate 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 2 – 1 Install and wire the communicator to the control panel (on-site) • Assemble the communicator with mounting bracket 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 2 – 2 Install and wire the communicator to the control panel (on-site) • Insert the communicator into the cabinet and assemble the antenna 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 2 – 3 Install and wire the communicator to the control panel (on-site) • Wire the communicator to control panel PCLINK Cable Connector • Control panel: Red wire is on the right and black is on the left • Communicator: Must be reversed (Black wire is on the right and red wire is on the left) NOTE: See details in product manual for PC 1864/1832/1616 control panel 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 3 – Load the programming and test for best signal strength location Ensure the SIM card is inserted Power up the control panel The communicator will be programmed by loading the pre-programmed configuration from Connect 24 automatically Check Green LEDs. You must achieve full or medium signal strength. See details in product manual. If signal strength is poor, must relocate the control panel or use an external extension antenna kits 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 4 – Program communication options on the control panel via keypad GS 2060/TL 260 GS with PC 1864/1832/1616 control panel o Sections [301], [302], [303]: Program Communication Path • DCAA - Internal (Ethernet 1, Ethernet 2, GPRS 1, GPRS 2) o Section [350] : Program Communication Format (Communicator) • (If Option [301] (above) is set to DCAA, Option [350] must be set to SIA, sub-option 5) o Sections [351] to [376] : Program Call Direction o Section [382] : Enable T-LINK Interface (Option [5]) o Section [167] : Enable Communication Wait For ACK (Set to 60 seconds) o Section [401] : Enable DLS Session Through GPRS or Ethernet (Option [1]) 2 -Way Wireless Security Suite
Installation GS 2060/TL 260 GS Installation Step 5 – Test communication 1. Disconnect incoming phone line from TIP and RING on the control panel 2. Verify that LED 2 is on, this indicate that the unit is active 3. Create an alarm transmission 4. Verify alarm transmission by calling monitoring station 5. Re-connect the phone line, if necessary For back-up communication applications, perform steps 1 to 5 For primary communication applications, perform steps 3 and 4 only 2 -Way Wireless Security Suite
Installation LED Display Trouble Status LED (Yellow – first one from the left) Please see details about the trouble shooting on page 17 in product manual 2 -Way Wireless Security Suite
Installation LED Display Network Connection Status LED (Red – second one from the left) LED OFF • No network connection issue present LED ON • Physical Ethernet cable is not connected • DHCP configuration fails • Fails to get an IP address from the GPRS network • GPRS connections has been reset LED blinks quickly once • Ethernet transmitting LDE blinks quickly twice • Ethernet receiving 2 -Way Wireless Security Suite
Installation LED Display Signal Strength LED 2 (Green – third one from the left) Signal Strength LED 1 (Green – fourth one from the left) Green LED 2 blinks quickly once • GPRS transmitting Green LED 2 blinks quickly twice • GPRS receiving 2 -Way Wireless Security Suite
Installation Keypad Trouble Display Trouble Condition • General System Trouble Panel Event Buffer Description • T-Link Network Fault/Restore includes ØSIM Lock Trouble ØGSM Trouble ØEthernet Trouble ØConnect 24 Configuration Trouble Ø • T-Link Receiver Trouble/Restore includes ØReceiver Not Available Trouble ØReceiver Supervison Trouble ØFTC Trouble • T-Link Comm. Fault/Restore includes ØPanel Absent Trouble 2 -Way Wireless Security Suite
GS 2060/TL 260 GS – Applications 2 -Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Communicator Controlled Call Routing – Backup (dual-path) – Redundant (dual-path) Required Programming Panel Sections [301], [302] and [305] • Any of them could be programmed as DCAA (default): Ethernet 1 → Ethernet 2 → GRPS 1 → GPRS 2 Communicator Sections [005] Option [4] - Primary and backup path [ON]: GPRS path primary, Ethernet path backup [OFF]: Ethernet path primary, GPRS path backup Option [5] - Redundant between GPRS path and Ethernet path [OFF]: Disable redundancy [ON]: Enable redundancy NOTE: “Primary and Backup Path” and “Redundant Communication” options need to be configured during the initialization of the account via Connect 24. 2 -Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Backup Mode 1: Ethernet Primary, 4 Receivers 2 -Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Backup Mode 2: Ethernet Primary, 2 Receivers 2 -Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Backup Mode 3: GPRS Primary, 4 Receivers 2 -Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Backup Mode 4: GPRS Primary, 2 Receivers 2 -Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Redundant Mode: 4 Receivers – (Redundancy between GSM/GPRS path and Ethernet/Internet path) NOTE: The application requires 4 different SG receivers or SG-DLR 3 IP line cards 2 -Way Wireless Security Suite
Applications Other Applications Periodic Test transmission • Individual periodic test via GPRS and Ethernet • Daily, Weekly and Monthly Interval • Configured during the initialization of the account via Connect 24 Encryption • 128 Bit AES Encryption • Turned on by central monitoring station Sur-Gard receiver • Encrypted communications enabled after next event sent to the receiver NOTE: Enabling this feature will require more data usage. Read-only Options from Keypad • Read all the options of the communicator from LCD keypad • Control panel option [851] 2 -Way Wireless Security Suite
Applications Other Applications Power Save Mode • Extend the battery duration when an AC power loss on control panel • Ethernet functionality turned off until a new event need to be transmitted • Network Connections LED: OFF • Incoming DLS connection will not be possible Hardware Default • Reset the programming options to the factory setting (default values) NOTE: Please see details in product manual Software Update • Update the firmware through DLS IV locally via PCLINK • Update the firmware through DLS IV remotely via Ethernet/Internet (TL 260 GS only) 2 -Way Wireless Security Suite
Applications SIA Report Code Event SIA Data Code Panel Absent Trouble Restore Radio Activation Restore Ethernet 1 Test Transmission GPRS 2 Test Transmission FTC Restore ET ER RS RP RP RP YK SIA Address Field 001 001 003 004 001 Example: Nri 0 ET 001 N= New Event ri 0=Partition/Area identifier ET= Panel Absent Restore 001=Zone 001 NOTE: GPRS 2 Test Transmission will only be sent when two different APNs are programmed. 2 -Way Wireless Security Suite