First Level Response… Complete Radiation Protection • Gamma/Neutron • Search • Dose Rate • Nuclide Identification Combined In One Handheld! + PROVEN LEADERSHIP IN INNOVATIVE AND RELIABLE RADIATION DETECTION TECHNOLOGY
The Identifier — Key Features • “ 3 Instruments-In-One”: Search, dose rate and nuclide identification • • Fully automatic: 2 -step operation • • GR-135 Unsurpassed nuclide identification Highest operation usability, one hand, one button, “joystick” operation Up to 4 detectors integrated into one instrument Integrated Neutron detection capability Developed based on the World’s leading gamma - ray spectrometer, the GR-130 mini. SPEC Key Features THE IDENTIFIER
Automatic Mode — 2 Step Operation Docking Station > System Ready The IDENTIFIER - Ease Of Use Key Applications Grab & Go > Search and dose rate GR-135 “Click” > Nuclide Identification THE IDENTIFIER
Highest Operator Usability GR-135 Ergonomics • • One hand, one button, “joystick” operation Operate with gloves Rugged and lightweight Well balanced “in-the-hands” feel The IDENTIFIER - Ease Of Use Key Applications THE IDENTIFIER
Highest Operator Usability GR-135 Easy To Use • Docking station: System ready, battery charged, gain stabilized • Fully automatic: 2 step operation 1. Grab & go - Search & Dose Rate 2. “Click” - Nuclide Identification • Large readable displays • Automated operator advisor - Warning Messages - Operator Instructions • “Eyes-Free” audio search and warning system • Selectable back-lit-display • Automated correction for display contrast • 8 to 12 hour battery life, with rechargeable batteries • Multi language support The IDENTIFIER - Ease Of Use Key Applications THE IDENTIFIER
Highest Operator Usability GR-135 Multiple On-Board Detectors • Up to 4 detectors can be integrated into one hand-held Sodium Iodide - standard on all instruments – Geiger-Mueller - standard on all instruments – Solid State Neutron - optional – Cadium Zinc Telluride (CZT) - optional – • Automatic detector data integration for optimal nuclide identification • Full text nuclide classification Industrial / medical / special nuclear materials – Nuclide identification – The IDENTIFIER - Ease Of Use Key Applications THE IDENTIFIER
Automatic Operator Friendly “Advisor” GR-135 “Eyes-Free” Audio Warning System • • Built-in audio output • Operator is able to quickly locate the exact location of the source Audio tone increases as The Identifier is moved close to the source and radiation becomes more intense Audio tone increases as radiation becomes more intense The IDENTIFIER - Ease Of Use Key Applications THE IDENTIFIER
Automatic Operator Friendly “Advisor” GR-135 Automatically advises operator. . . Warning Audio tone increases as radiation becomes more intense Warning Instruction The IDENTIFIER - Ease Of Use Key Applications THE IDENTIFIER
Automatic Mode: Search and Dose Rate Highly sensitive search / survey capability: GR-135 Accurate, calibrated dose measurement: - Uses a very sensitive sodium iodide detector (4 cu. in. / 65 cu. cm) - Dose calibrated based on Cesium 137 at factory - Measures total counts per second - Dose accurate to +/5% over 0 - 3 Me. V range - Chart recorder to emphasize small radiation level changes - Energy corrected dose rate - “Eyes-Free” audio search to locate source - “Neutron alert” if neutrons detected (Neutron optional) The IDENTIFIER - Ease Of Use Key Applications - BAR GRAPH gives user an easy visual display of dose hazard - High dose rate alarm THE IDENTIFIER
Automatic Mode: Unsurpassed Nuclide Identification • Exploranium has developed a technologically advanced nuclide identification system “multi-level nuclide I. D. ” that uses advanced deconvolution peak techniques and interference correction techniques • Optimized for all common nuclides and Special Nuclear Materials (SNM) i. e. Uranium-235, Plutonium • • • Optimized for shielded sources • • • GR-135 Automatic gain correction 1024 channel operation Automatic detector selection: Sodium Iodide vs Cadmium Zinc Telluride Clearly displays Type and Isotope Automatically alarms and displays Neutrons The IDENTIFIER - Ease Of Use Key Applications THE IDENTIFIER
Nuclide Libraries • GR-135 Nuclide libraries target most common nuclides for Special Nuclear Materials, Industrial and Medical applications • 5 different pre-defined nuclide libraries are available. The desired library is activated through the manual menu selection: – STANDARD: Customs / Security / Police / Military. . . – Medical – Industrial – Waste Management • Special Customizable For maximum system performance, Exploranium will customize special libraries for the user (by e-mail) which can be downloaded using the indenti. VIEW software provided via PC and docking station The IDENTIFIER - Ease Of Use Key Nuclide Library Applications THE IDENTIFIER
GR-135 Libraries • GR-135 Built-In Library for First Responders (Customs, Police, Fire, etc. ), Medical, Industrial and Waste BUILT-IN LIBRARIES Standard (Customs) The IDENTIFIER - Ease Of Use Key Nuclide Library Applications Medical THE IDENTIFIER
GR-135 Libraries • GR-135 Built-In Library for First Responders (Customs, Police, Fire, etc. ), Medical, Industrial and Waste BUILT-IN LIBRARIES Industrial The IDENTIFIER - Ease Of Use Key Nuclide Library Applications Waste THE IDENTIFIER
identi. VIEW Software GR-135 “Dock to PC” > identi. VIEW Software • • The Identifier has a large data storage capability • Stored data can then be transmitted to an expert for review Identi. VIEW software automatically downloads stored data and spectrum to your PC The IDENTIFIER - Ease Of Use Key Applications identi. VIEW Software THE IDENTIFIER
Manual Mode Features — Advanced User GR-135 Manual Mode The manual mode allows the qualified user the opportunity to change parameters, alarm levels, etc. , for both the Automatic and Manual modes, as well as perform advanced spectrum analysis and other advanced functions. Set-Up Mode The menu-driven “Manual mode” allows the advanced user to easily define or modify system settings: • Survey settings • Dose corrections • Manual detector selection / override • Count termination settings • • • Alarm message / audio control settings Display settings Scan stored spectra / replay / download Battery condition Dose calibration / data averaging Multiple language The IDENTIFIER - Ease Of Use Key Applications THE IDENTIFIER
Manual Mode Features — Advanced User GR-135 Advanced Spectrum Analysis Using a full complement of on-board analysis tools and system pop-up menus, the IDENTIFIER provides the advanced user with everything needed to manipulate and analyze the spectrum. • Adjust scaling, zoom and expand peaks of interest • • • Customize system settings Define multiple regions of interest (ROI) Re-play, allows the re-analysis of selected stored spectra The IDENTIFIER - Ease Of Use Key Applications THE IDENTIFIER
Training GR-135 • Exploranium is in the process of developing a number of training programs ranging from 2 hours to a full day. • These seminars include such topics as: 3 Basic Radiation Knowledge 3 Field-Based Role Exercises 3 3 GR-135 Operation 3 3 Emergency Response Search Techniques Standard Operating Procedures (SOP) • Seminar leaders include; in North America — Don Rickard previously with Canadian Nuclear Safety Commission and in Europe — Dr. Klaus Duftschmid, previously with the IAEA and currently involved in customs training • Exploranium is also working on an interactive training CD and can provide training for trainers The IDENTIFIER - Key Applications THE IDENTIFIER
“The IDENTIFIER” - Complete Package GR-135 The Complete Package Includes: • • • GR-135 “The Identifier” handheld unit Operator’s manual Rubber boot Docking station + AC power cord 2 - Ni. Cd - batteries Connection cable (docking station to PC) Identi. VIEW software Soft sided carrying case Pelican shock proof travel/shipping case Calibration certificate ISO 9002 CE The IDENTIFIER - identi. VIEW Software The IDENTIFIER - Ease Of Use The Complete Key Applications Package THE IDENTIFIER
Only Exploranium Provides. . . • Automatic Mode - 2 step operation – “Grab and Go” = Search and Dose Rate – “Click” = Nuclide Identification • • One hand, one button “joy stick” operation • Docking station - recharging, stabilization and downloading • • • Large, readable displays 65 x 65 mm (2. 5” x 2. 5”) • • • GR-135 Rugged, durable design - drop tested at 0. 75 m, with detectors Unsurpassed nuclide identification - optimized for shielded sources and special nuclear materials Eyes-free “loud” audio, warning messages 4 integrated multiple detectors - NAI, GM, Neutron, CZT Free software upgrades Automatic detector selection - NAI versus CZT Five nuclide libraries including a customizable nuclide library Large NAI crystal 38 mm x 55 mm (1. 5” dia x 2. 2”) for extra sensitivity Excellent battery life, 8 hrs to 12 hrs Broad energy range 20 Ke. V to 3. 0 Me. V and selectable ROI’s Multi language support The IDENTIFIER - identi. VIEW Software The IDENTIFIER - Ease. Provides… Key Of Use Only Exploranium Applications THE IDENTIFIER
Independent Test Evaluations - In Progress! • GR-135 The IDENTIFIER is a significant technical advance over the original Exploranium’s GR-130 mini. SPEC which was successfully evaluated by a number of organizations: – ITRAP - IAEA Seibersdorf, Austria – NRPB, U. K. – AECL, Canada – F. B. I. / D. O. E. , USA • GR-135 IDENTIFIER - Tests In Progress. . . – Department of Energy (D. O. E. ) - United States – I. T. R. A. P. - Austria – N. R. P. B. - United Kingdom – Customs - Europe The IDENTIFIER - identi. VIEW Software The IDENTIFIER - Ease. Evaluations Key Of Use Independent Test Applications THE IDENTIFIER
User References: • GR-135 The GR-130 / 135 has sold over 1, 500 units in 45 countries, with such notable customers as: – Customs: U. S. Customs (USA), CCRA (Canada), – Police: FBI (USA), RCMP (Canada), Police (Worldwide) – Military: D. O. D. , U. S. Army, LLNL, Navy EOD, Navseacom, AWE (UK), DND (Canada) – National Research Facilities: DOE (USA), AECL (Canada), NRPB (UK), I. A. E. A. (Austria), ANSTO (Australia), Health Canada R. P. B. – Medical: Medical facilities worldwide, Hospitals. . . – Nuclear Power Plants: OPG, Bruce, NBP (Canada), USA, Europe – Steel/Scrap Metal: Nucor, Ameristeel (USA), Avesta, ELG (UK), Nippon Steel (Japan), most steel mini-mills worldwide. . . The IDENTIFIER - identi. VIEW Software The IDENTIFIER - Ease. Evaluations Key Of Use Independent Test Applications THE IDENTIFIER
In Conclusion - The IDENTIFIER • Evolved from the most popular gamma-ray spectrometer, the GR-130 mini. SPEC • 3 instruments in one: search, dose rate and nuclide identification • • • Fully automatic: 2 step operation • • GR-135 Selectable nuclide libraries Lightweight, rugged and versatile Highest operator usability: Easy to use Unsurpassed nuclide identification Docking station for immediate readiness Multiple integrated detectors: GM, Sodium Iodide, Neutron, CZT Manual mode for advanced users The IDENTIFIER - identi. VIEW Software The IDENTIFIER - Ease Of Use The Complete Key Applications Package THE IDENTIFIER
For More Information GR-135 USA Offices Head Office Contact: Mel Sauve E-mail: sauve@exploranium. com 6108 Edwards Blvd. , Mississauga, Ontario CANADA L 5 T 2 V 7 Tel. : (+1) 905 670 -7071 ext. 305 Fax: (+1) 905 670 -7072 European Office Europe, Middle East, Africa Contact: D. J. Schooneveld E-mail: d. j. schooneveld@euronet. nl Lagendijk 39, NL-1541 KB Koog aan de Zaan, The Netherlands Tel. : (+31) 75 670 4901 Fax: (+31) 75 670 4855 Nuclear - Asia, South America, Australia, South Africa Contact: Roy Natherson E-mail: natherson@exploranium. com 6108 Edwards Blvd. Mississauga, Ontario CANADA L 5 T 2 V 7 Tel. : (+1) 905 670 -7071 ext. 304 Fax: (+1) 905 670 -7072 Where To Find. Key Applications Us. . . The IDENTIFIER - identi. VIEW Software The IDENTIFIER - Ease Of Use Nuclear / Security Contact: Stan De. Filippis mail: defilippis@exploranium. com 207 E. Ohio St. , Suite 262 Chicago, IL 60611 USA Tel. : (630) 922 -6483 Fax: (630) 922 -6482 Steel / Scrap Metal - North America, South America & Asia Contact: John Bublitz E-mail: bublitz@exploranium. com 237 South Peters Rd. Knoxville, Tennessee USA 37923 Tel. : (865) 539 -6099 Fax: (865) 539 -1916 Nuclear Surveillance / Geophysical - International Contact: Ed Mc. Govern E-mail: mcgovern@exploranium. com 6108 Edwards Blvd. Mississauga, Ontario CANADA L 5 T 2 V 7 Tel. : (+1) 905 670 -7071 ext. 303 Fax: (+1) 905 670 -7072 E-