Compomat® G 4 Federico Voglino – PM SE & ME Region
Compomat® G 4 Compomation Datamanagement Concept Compomaster™ NET Software Compomat® G 4 Hardware Federico Voglino – PM SE & ME Region
Quality in performance Compomat® G 4 Pressed for Quality and Performances Compomat G 4 can satisfy the increasing demand in quality and standardization in blood component preparation. Many Blood Banks in Europe are ISO certified or certifying. The demand for quality, standardization and processing data management is rapidly increasing. Compomat G 4 can give the highest plasma and platelet yield and can improve the profitability of Blood component preparation. Federico Voglino – PM SE & ME Region
Compomat G 4 - Hardware Control Panel Federico Voglino – PM SE & ME Region
Compomat G 4 - Hardware Menu selection Display Scroll buttons Enter Federico Voglino – PM SE & ME Region
Compomat G 4 - Hardware Operator buttons Start Door Close Door Open Pause Stop On/Off Federico Voglino – PM SE & ME Region
Compomat G 4 - Hardware Upper and Lower Press with Slide and Multi Detection Federico Voglino – PM SE & ME Region
Compomat G 4 - Hardware Upper and Lower Press programmable in steps of 0. 1 mm Multi Detection Slide Federico Voglino – PM SE & ME Region
Compomat G 4 - Hardware Motor controlled flow limiter with integrated detection Federico Voglino – PM SE & ME Region
Compomat G 4 - Hardware Motor controlled flow limiter B detection in: • Normal mode • Fast mode Federico Voglino – PM SE & ME Region
Compomat G 4 - Hardware 6 Close – Seal heads Federico Voglino – PM SE & ME Region
Compomat G 4 - Hardware • Tube positioning checking • High seal quality • User friendly maintenance Federico Voglino – PM SE & ME Region
Compomat G 4 - Hardware Two scales for automatic registration of weights Top press Federico Voglino – PM SE & ME Region
Compomat G 4 & Compomaster NET Compo. Mat® G 4 Compo. Master NET Federico Voglino – PM SE & ME Region
Compomat G 4 - Procedure Upper and Lower Press independently programmable one from each other Federico Voglino – PM SE & ME Region
Compomat G 4 - Procedure Federico Voglino – PM SE & ME Region
Compomat G 4 - Procedure Motor controlled flow limiter Buffy-Coat volume programming by Upper Press distance Federico Voglino – PM SE & ME Region
Compomat G 4 - Procedure Hct programming by Multi Detector Federico Voglino – PM SE & ME Region
Compomat G 4 - Procedure Slide to separate Buffy–Coat from erythrocytes Federico Voglino – PM SE & ME Region
Compomat G 4 - Procedure Plasma Buffy-Coat Erythrocytes Federico Voglino – PM SE & ME Region
Compomat G 4 - Procedure Detection B/BF Minimal lost of Buffy-Coat / Erythrocytes Optimal Plasma yield Optimal Erythrocytes yield Federico Voglino – PM SE & ME Region
Compomat G 4 & Compomaster NET Federico Voglino – PM SE & ME Region
Compomaster NET • Allows personalization/modification on-line & step-by-step of the separation programs. • Allows to save 50 different protocols. • Can manage up to 24 Compomat G 4 network linked. • Store, print and exports the procedure data, even in Excel format, customizable based on customer needs. • Allows procedure data transferring to the Blood Bank computer system. • Bi-directional communication between Compomat and computer system. Federico Voglino – PM SE & ME Region
Compomaster NET Federico Voglino – PM SE & ME Region
Compomaster NET Federico Voglino – PM SE & ME Region
Compomaster NET Federico Voglino – PM SE & ME Region
Compomaster NET Federico Voglino – PM SE & ME Region
Compomaster NET Federico Voglino – PM SE & ME Region
Compomaster NET Federico Voglino – PM SE & ME Region
Compomaster NET Federico Voglino – PM SE & ME Region
Compomaster NET Federico Voglino – PM SE & ME Region
Compomaster NET Federico Voglino – PM SE & ME Region
Compomaster NET • All kind of Bar Code reader recognition and check. • Time limit set for each process (Watch dog). • Compomaster NET – three levels for operation: – G 4 stand-alone. – G 4 computer linked: “Master” level. – Programming level. • Compomaster NET safety features for the operator: – – Door close check: the door opens in case of obstruction. Tube positioning check, with acoustic alarm. G 4 Stand by mode at the end of operator checks. SAG-M squeezing. Federico Voglino – PM SE & ME Region
Compomat G 4 - Strengths • Flexibility in programming (50 programs). • One balance for plasma and another one for Red Cells or BC. • High standard and reproducible quality of blood components. • Six clamp/sealing heads for complete automation of all existing bags up to quintuple. • The finest regulation in separation parameters. Federico Voglino – PM SE & ME Region
Compomat G 4 - Strengths • Speed and quality in separation with ALL bags. • All bag systems can be used. • Integration and automation of In-line systems on Compomat • Maximal plasma yield collection and high platelet yield collection optimizing the profitability of the blood component separation. • Integrate offering package deals with blood bags. Federico Voglino – PM SE & ME Region
Compomat G 4 - Strengths Connected to Compomaster • Bidirectional communication between Compomaster-NET and the Blood Bank Host computer • Automated procedure by Compomaster NET and Compomation save labor cost • Compomaster-NET under Windows XP Federico Voglino – PM SE & ME Region
Compomat G 4 - Strengths Patented: • A patent has been granted concerning the triple press construction of Compomat (the essence of the product) in: • • USA Japan Germany England France Sweden Italy the Netherlands Federico Voglino – PM SE & ME Region
Ordering Information • 9028221 Compomat G 4 • 902428/3 Air compressor • 9024181 Weighing scale • 9024391 Bar code scanner • 9024101 PC Compomat G 4 w/ Phone. NET card, GB language (w/Monitor) Federico Voglino – PM SE & ME Region
Contact Information • For any further information you may need, please contact: Federico Voglino Product Manager SE & ME Region federico. voglino@fresenius-kabi. com +39 -0535 -45446 Fresenius Kabi Transfusion Technology Federico Voglino – PM SE & ME Region